Icomメーカーic pw1の使用説明書/サービス説明書
ページ先へ移動 of 20
INSTR UCTION MANU AL iPW1 HF/50 MHz ALL BAND 1 kW LINEAR AMPLIFIER.
R W ARNING HIGH V OL T A GE! NEVER attach an antenna or internal antenna connector during trans- mission. This ma y result in an electrical shock or b ur n. R W ARNING! NEVER carr y the linear amplifier by yourself . At least two persons must carry the linear amplifier since it weights appro x.
IMPORT ANT ...................................................... i PRECA UTIONS ................................................. i EXPLICIT DEFINITIONS .................................. ii T ABLE OF CONTENTS .................................... ii UNP A CKING .
1 1 P ANEL DESCRIPTION ■ Fr ont panel and remote controller 0 100 250 500 1K 1 .5K 0 TEMP ALC ALC ad j SWR 0 1 1.5 2 3 10 20 30 40 50 60 V D HOT I D Po 10 20 30 40 50 60 W A METER-1 METER-2 P o TEMP I D V D ALC SWR DOWN 1 .
2 1 P ANEL DESCRIPTION q PO WER SWITCH [PO WER] (p . 11) Push momentarily to tur n power ON. w TRANSMIT INDICA T OR [TRANSMIT] (p . 13) Lights green while transmitting.
q OUTPUT ANTENNA CONNECT ORS [ANT1] – [ANT4] (p . 6) Accept a 50 Ω antenna with a PL-259 connector . w A CCESSOR Y SOCKET -1 [A CC-1] A CCESSOR Y SOCKET -2 [A CC-2] Enable connection to Icom e xciters (transceivers). - See the page at right for soc ket inf or mation.
4 1 P ANEL DESCRIPTION D A CC-1 SOCKET D A CC-2 SOCKET (w/[EXCITER] is “ 1 ” ) The f ollowing descriptions are applied when the [EXCITER] s witch is set to “ 1 ” (default). When [EX- CITER] is set to “ 1&2, ” [ACC-2] functions the same as [A CC-1] abov e for the 2nd e xciter .
5 2 INST ALLA TION AND CONNECTIONS (1) Single-phase 3-wire line (200 – 240 V A C) q The green wire from the A C power cab le must be connected to the protective earth. w The blac k and white wires from the A C power cable can be connected to either terminal.
■ Gr ounding T o pre v ent electr ical shock, tele vision interference (TVI), broadcast interference (BCI) and other prob- lems, g round the linear ampli fi er through the GROUND terminal on the rear panel. F or best results, connect a heavy gauge wire or str ap to a long ear th-sunk copper rod.
■ System inter connections 1 or 2 Icom 100 W HF transceiv ers can be connected as e xciters to the IC-PW1. Non-Icom transceivers can be used, how ev er , band selection will not be synchro- nized f or each exciter . See the f ollo wing diag r ams f or making connections be- tween the IC-PW1 and an e xciter (transceiv er).
8 2 INST ALLA TION AND CONNECTIONS • Using 2 Icom exciter s (transceivers) The f ollowing connections also apply to trans- ceiv ers having multiple antenna connectors f or speci fi ed bands (e.
9 2 INST ALLA TION AND CONNECTIONS • Using 1 Icom and 1 non-Icom exciter s (transceivers) NO TE: The speci fi cations f or the SEND relay are 5 V DC 0.
10 2 INST ALLA TION AND CONNECTIONS The control section of the linear ampli fi er can be sep- arated from the main body , doubling as a remote con- troller . It can be placed on the e xciter or in another conv enient place. q Disconnect the A C power cab le.
■ Setting the ALC levels Bef ore fi rst applying power , make sure all connections required f or your system are complete b y referring to chapter 2. Then, reset the linear amplifier using the f ollowing procedure. NO TE: Resetting CLEARS all programmed set- tings to def ault values .
12 3 OPERA TION The IC-PW1 uses CI-V frequency data f or automatic selection of the operating band. Program the e xciter ’ s address to use this capability as f ollows: F or non-Icom exciters , the IC-PW1 cannot be con- trolled using the CI-V function, so this setting is not necessar y .
13 3 OPERA TION CA UTION: DO NO T operate the IC-PW1 before adjusting the ALC le vels properly with the [ALC adj1] and [ALC adj2] pots. (p . 11) It takes 15 sec. f or CI-V line initial settings when se veral CI-V de vices (more than 5) are connected to a CI-V line.
3 OPERA TION 14 This linear ampli fi er has v ar ious protection circuits. D ALC circuit The ALC (A utomatic Lev el Control) circuit automati- cally limits RF output power b y controlling the input le vel of the e xciter . This prev ents transmission of dis- tor ted signals when the input signal lev el e xceeds the allow able le vel.
4 MAINTENANCE 15 PROBLEM POSSIBLE CAUSE SOLUTION REF. Power does not come on when the [POWER] switch is pushed. • Cable connection is faulty. • The circuit breaker is turned OFF. • Check the connection and connection cable pins. • Check for the cause, then turn the circuit breaker ON.
5 SPECIFICA TIONS 16 ■ General • F requency cover age: 0 1.800 – 0 1.999 MHz 0 3.500 – 1 3.999 MHz 0 7.000 – 1 7.300 MHz 10.100 – 10.150 MHz 14.000 – 14.350 MHz 18.068 – 18.168 MHz 21.000 – 21.450 MHz 24.890 – 24.990 MHz * 1 28.000 – 29.
6-9-16 Kamihigashi, Hirano-ku, Osaka 547-0002 J apan A-5449G-1EX- w Printed in Japan © 1997 Icom Inc. Count on us!.
デバイスIcom ic pw1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Icom ic pw1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはIcom ic pw1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Icom ic pw1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Icom ic pw1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Icom ic pw1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はIcom ic pw1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Icom ic pw1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちIcom ic pw1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。