USER’S MANUAL QUESTIONS? If you have questions, or if there are missing parts, we will guar- antee complete satisfaction through direct assistance from our factory . TO A VOID DELA YS, PLEASE CALL DIRECT TO OUR T OLL- FREE CUSTOMER HOT LINE. The technicians on our customer hot line will provide immediate assistance, free of charge.
2 IMAGE is a registered trademark of ICON Health & Fitness, Inc. Posting the W arning Sign . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Important Safety Instructions .
3 W ARNING: T o reduce the risk of drowning, electric shock, or serious injury , read the fol- lowing important precautions before using the hydrotherapy spa. READ AND FOLLOW ALL INSTRUCTIONS 1. It is the responsibility of the owner to ensure that all users of the hydrotherapy spa are adequately informed of all precautions.
4 20. DANGER—Risk of electric shock. Keep all electrical appliances such as radios, tele- phones, televisions, and lights at least five feet away from the water . 21. A wire connector is provided on the electron- ics pack of the hydrotherapy spa to connect a minimum No.
5 W ARNING: Read all instructions before using the hydrotherapy spa. ICON assumes no responsibility for personal injury or property damage sustained by or through the use of this product. SA VE THESE INSTRUCTIONS 35. W ARNING: The spa jets produce a stream of water with relatively high pressure.
6 Congratulations for selecting the new IMAGE ® RENEW 639 hydrotherapy spa. The innovative RENEW 639 allows you to enjoy all the benefits of hydrotherapy in the comfort and privacy of your home. Hydrotherapy is a proven method for soothing tired muscles after exercise or for relieving the stress of a busy life.
7 There are many factors to consider when choosing a location to set up the hydrotherapy spa. These factors vary depending on whether you plan to use the spa inside or outside. We have listed several factors you may wish to consider as you decide where to set up the spa.
8 2. Close the valve knob on the drain hose. Thread the cap onto the drain hose. Locate the four gate valves inside the access open- ing (there are two gate valves per pump). Make sure that the gate valves are open and that the locking clips are snapped onto the stems of the gate valves, as shown in the inset drawing.
9 5. Make sure that a qualified electrician has wired the spa to a 240-volt power source. Remove the two warning decals (see page 5) from the spa shell. Using a damp cloth, wipe the spa shell clean. Before filling the spa, make sure that it is in the desired position and that there is room to easily service it.
10 The hydrotherapy spa is designed to seat seven adults. The spa holds approximately 375 gallons of water and offers a heating system (80°F to 104°F), a filtration system, and adjustable hydrotherapy jets. Follow the guidelines below to use and maintain the spa for your long-term enjoyment.
A. The filters can be removed for cleaning or replace- ment (see CHECKING AND CLEANING THE FIL- TERS on page 13). B. The underwater light can be used for night opera- tion (see USING THE CONTROLS on page 12). The spa includes both red and blue covers for the light.
12 Using the Controls Air Control 1: Determines the amount of air flowing through the hydrotherapy jets labeled 1 (above). If the control is turned counterclockwise, the amount of air will increase; if the control is turned clockwise, the amount of air will decrease.
13 The hydrotherapy spa is designed to provide years of enjoyment. Please follow the guidelines below to properly maintain your spa. MAINTENANCE SCHEDULE Daily • Check the water level and refill the spa to the level shown in step 5 on page 9. • Check the pH balance and sanitizer level.
14 MAINT AINING THE PROPER PH BALANCE The pH factor is a measure of the relative acidity or alkalinity in the water , and is measured on a scale of 1 to 14. Pure water has a value of 7, which is neutral. Any value above 7 is alkaline, and any value below 7 is acidic.
15 T o drain the hydrotherapy spa, follow the steps below: 1. Using the console, adjust the temperature to the lowest setting. 2. Shut off the power to the spa, at the circuit breaker or GFCI. 3. Remove the access panel from the spa (see A TT ACHING AND REMOVING THE ACCESS P ANEL on page 14).
16 1. SYMPTOM: THE SP A WILL NOT OPERA TE a. Check to see if the GFCI breaker is tripped or was not turned on. Reset the GFCI breaker . 2. SYMPTOM: THE CIRCUIT BREAKER OR THE GFCI TRIPS WHILE THE SP A IS OPERA TING a. Reset the circuit breaker or the GFCI.
17 9. SYMPTOM: THE W A TER LEVEL DROPS a. A clamp or seal inside the pump compartment may be loose. Check inside the pump compart- ment for excess water and watch the pump unit while it is operating to see if water drips from any of the plumbing.
18 Part List —Model No. IMSB63910/IMSG63910 R1 101A 1 1 Thermometer Fitting 2 1 3-wire Power Cord 3 2 Filter Cover with O-Ring 4 2 Filter O-Ring 5 2 Filter 6 2 Rubber Isolator 7 1 Blue Light Cover 8.
19 26 27 25 18 29 18 11 13 10 9 31 13 13 19 9 31 13 20 1 12 2 15 37 43 44 36 40 39 41 42 41 38 35 46 46 16 17 16 17 16 17 16 17 46 46 25 6 6 9 5 3 4 5 3 4 47 45 48 45 48 49 14 9 9 54 52 53 53 55 23 Exploded Drawing —Model No.
Part No. 180722 R1 101A Printed in USA © 2001 ICON Health & Fitness, Inc. T o order replacement parts, simply call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday , 6 a.m. until 6 p.m. Mountain T ime (excluding holidays).
デバイスImage IMSG63910の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Image IMSG63910をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはImage IMSG63910の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Image IMSG63910の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Image IMSG63910で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Image IMSG63910を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はImage IMSG63910の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Image IMSG63910に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちImage IMSG63910デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。