Ingersoll-RandメーカーPD05P-XXX-XXXの使用説明書/サービス説明書
ページ先へ移動 of 8
CCN 99713398 OPERA T OR’S MANU AL PD05P - X X X -X X X INCL UDING: OPERA TION, INST ALLA TION & MAINTENANCE RELEASED: 5-15-98 REVISED: 11-12-10 (REV . J) 1/2" DIAPHRA GM PUMP 1:1 RA TIO (MET ALLIC) READ THIS MANUAL CAREFULL Y BEFORE INST ALLING, OPERA TING OR SERVICING THIS EQUIPMENT .
Page 2 of 8 PD05P-X XX- XXX (en) W ARNING EX CESSIVE AIR PRESSURE. C an cause per- sonal injury , pump damage or property damage. Do not ex ceed the maximum inlet air pr essure as stated on the pump model plate . Be sure material hoses and other componen ts are able to withstand fluid pressures dev eloped by this pump .
PD05P-X XX- XXX (en) Page 3 of 8 OPERA TING INSTRUCTIONS Always flush the pump with a solvent c ompatible with the material being pumped if the material being pumped is subject to “setting up ” when not in use for a period of time. Disconnect the air supply from the pump if it is to be in- active for a few hours .
Page 4 of 8 PD05P-X XX- XXX (en) P ARTS LIST / PD05P- XX X- XX X FL UID SEC TION 637140-X X Fluid Section Ser vic e Kits include: Balls (see Ball Option, refer to - XX in chart below), Diaphragms (see Diaphragm O p- tion, refer to - XX in chart below), and items 2 and 19 (listed below) plus 93706-1 K ey-Lube gr ease packet (page 6).
PD05P-X XX- XXX (en) Page 5 of 8 19 62 15 22 22 12 21 12 21 19 61 (models PD05P-AAS- XX X) 26 61 (models PD05P-ASS- XX X) 43 26 60 (models PD05P-ASS- XX X) 63 .
Page 6 of 8 PD05P-X XX- XXX (en) P ARTS LIST / PD05P- XX X- XX X AIR MO TOR SECTION 9 Indicates par ts included in 637141 air sec tion repair kit. MA TERIAL CODE [B] = Nitrile [D] = Acetal [SY ] = Syn.
PD05P-X XX- XXX (en) Page 7 of 8 P ARTS LIST / PD05P- XX X- XX X AIR MO TOR SECTION ) T ORQUE REQUIREMENTS ( NO TE: DO NOT O VERTIGHTEN F ASTENERS. (134) T orque to 15 - 20 in. lbs (1.7 - 2.3 Nm), wait 10 minutes, then re-torque to 15 - 20 in. lbs (1.
Page 8 of 8 PD05P-X XX- XXX (en) PN 97999-781 TROUBLE SHOO TING Product discharged from air e xhaust. Check for diaphragm ruptur e. Check tightness of (14) bolt. Air bubbles in product discharge. Check connections of suction plumbing. Check “O” rings between intake manifold and uid caps.
デバイスIngersoll-Rand PD05P-XXX-XXXの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Ingersoll-Rand PD05P-XXX-XXXをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはIngersoll-Rand PD05P-XXX-XXXの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Ingersoll-Rand PD05P-XXX-XXXの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Ingersoll-Rand PD05P-XXX-XXXで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Ingersoll-Rand PD05P-XXX-XXXを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はIngersoll-Rand PD05P-XXX-XXXの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Ingersoll-Rand PD05P-XXX-XXXに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちIngersoll-Rand PD05P-XXX-XXXデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。