Ingersoll-RandメーカーPD10E-X-Xの使用説明書/サービス説明書
ページ先へ移動 of 8
INGERSOLL RAND COMP ANY L TD P .O . BOX 151 ONE ARO CENTER BR Y AN, OHIO 43506-0151 (800) 276-4658 F AX (800) 266-7016 © 2009 CCN 15244940 OPERA T OR’ S MANU AL PD10E- X- X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 6-15-05 REVISED: 5-25-09 (REV .
Page 2 of 8 PD10E-X -X (en) EX CESSIVE AIR PRESSURE ST A TIC SPARK HAZARDOUS MA TERIALS HAZARDOUS PRESSURE W ARNING EX CESSIVE AIR PRESSURE. Can cause per- sonal injury , pump damage or property damage. Do not exc eed the maximum inlet air pressure as stated on the pump model plat e.
PD10E-X -X (en) Page 3 of 8 Page 3 of 8 GENERAL DESCRIPTION The ARO diaphragm pump oers high volume deliver y even at low air pr essure an d a broad rang e of material comp atibility options available. Refer to the model and option chart. ARO pumps feature stall resistant design, modular air motor / uid sections.
Page 4 of 8 PD10E-X -X (en) FL UID SECTION SERVICE KITS (637396-X X) KITS INCL UDE: BALLS (see Ball O ption, ref er to -X X in Service Kit char t below), DIAPHRAGMS (see Diaphr agm Option, refer to - XX in Service Kit char t below), and items 19, 33, 70, 144, 175 and 180 (listed below) plus 174 and 94276 L ubriplate F ML-2 gr ease (page 6).
PD10E-X -X (en) Page 5 of 8 Page 5 of 8 TORQU E REQUIREMENTS LUBRICA TION / SEALANTS Lubriplate FML-2 is a white food grade petroleum grease. cups & mating parts.
Page 6 of 8 PD10E-X -X (en) P ARTS LIST / PD10E-X -X AIR SECTION AIR MO T OR SEC TION SERVICE Ser vice is divided into two parts − 1. Pilot V alve, 2. Major V alve. GENERAL REASSEMBL Y NOTES: Air Motor Section Ser vice is continued from F luid Section repair .
PD10E-X -X (en) Page 7 of 8 Page 7 of 8 TORQUE REQUIREMEN TS ALL F ASTENERS ARE METRIC. LUBRICA TION / SEALANTS Apply anti-seize compound to threads at assembly . Apply Lubriplate FML-2 grease to “O" rings, ”U" Cups & mating parts. NOTE: DO NOT OVERTIGHTEN F ASTENERS.
Page 8 of 8 PD10E-X -X (en) PN 97999-1159 TROUBLE SHOO TING Product discharged from e xhaust outlet. Check for diaphrag m rupture. Check tightness of (6) diaphragm scr ew . Air bubbles in product discharge. Check connections of suction plumbing. Check“O” rings bet ween intake manifold and inlet side uid caps.
デバイスIngersoll-Rand PD10E-X-Xの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Ingersoll-Rand PD10E-X-Xをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはIngersoll-Rand PD10E-X-Xの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Ingersoll-Rand PD10E-X-Xの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Ingersoll-Rand PD10E-X-Xで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Ingersoll-Rand PD10E-X-Xを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はIngersoll-Rand PD10E-X-Xの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Ingersoll-Rand PD10E-X-Xに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちIngersoll-Rand PD10E-X-Xデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。