ISIS-II 8080/8085 MACRO ASSEMBLER OPERATOR'S MANUAL Manual Order Number: 9800292-04 Rev. D Copyright © 1977, 1979, 1980 Intel Corporation I Intel Corporation, 3065 Bowers Avenue, Santa Clara, Ca.
ii Additional copies of this manual or other Intel literature may be obtained from: Literature Department Intel Corporation 3065 Bowers A venue Santa Clara, CA 95051 The information in this document is subject to change without notice.
• n PREFACEI This manual describes operating procedures for the ISIS-II SOSO/SOS5 Macro Assembler. The assembler translates SOSO/S085 assembly language source code into object code executable on the SOSO/S085 microprocessors.
.
CHAPTER 1 ASSEMBLER OVERVIEW PAGE ISIS-II Assembler Environment. . . . . . . . . . . . . . . . . .. 1-1 Overlay and Nonoverlay Operating Modes ........ 1-1 Symbol Table Size. . . . . . . . . . . . . . . . . . . . . . . . . . . .. 1-2 Input/Output Files.
.
CHAPTER 11 ASSEMBLER OVERVIEW An assembler performs the clerical function of converting your assembly language program into machine-executable form. It accepts your source file and, depending on the output options selected, can produce an executable object file, a listing of the source and assembled code, and a symbol cross-reference listing.
Assembler Overview 8080/808S Assembler 1-2 Symbol Table Size In overlay mode with 32K of Intellec memory, you can generate slightly more than 200 symbols. In nonoverlay mode with 48K of memory, you can have slightly more than 800 symbols. Each 16K memory increment adds 2000 symbols.
8080/8085 Assembler Assembler Overview Symbol-Cross-Reference File During the first pass of the assembler, a file of symbol-cross-reference records is created, if requested.
.
CHAPTER 21 ~SEMBLER CONTROLS Introduction to Assembler Controls Assembler controls allow you to specify the input! output files or devices to be used by the assembler and whether list or object files (or portions of these files) are to be generated by the assembler.
Assembler Controls 808O/808S Assembler 2-2 Control PIG Function Area flAGELENGTH (66) P Listing Format PAGEWIDTH (120) P Listing Format TITLE G Listing Format EJECT G Listing Format GEN/NOGEN G Macro .
8080/8085 Assembler Primary Controls Control OBJECT(file) NOOBJECT MOD85 DEBUG NODEBUG PRINT(file) NOPRINT SYMBOLS NOSYMBOLS XREF NOXREF MACROFILE(drive) NOMACROFILE PAGELENGTH(n) PAGEWIDTH(n) Effect An object code file is generated and is output to the specified diskette file.
Assembler Controls Control PAGING NOPAGING MACRO DEBUG NOMACRODEBUG ITY NOTIY General Controls Control INClUDE(file) LIST NOLIST CONO NOCONO GEN NOGEN TITlE('string') EJECT SAVE RESTORE 2-4 Effect The assembler separates listing into pages with headers at each page break.
808O/808S Assembler Assembler Controls Defaults The following defaults are assumed by the ISIS-II assembler if the corresponding controls are not selected: OBJECT(file.
.
CHAPTER 31 ASSEMBLER OPERATION The ISIS-II SOSO/SOS5 Assembler resides on the ISIS-II system diskette. The assembler is loaded by calling ASMSO at the ISIS-II command level and specifying your source file along with any desired assembler controls (Chapter 2).
Assembler Operation SOSO/S08S Assembler 3-2 CBASE EaU ORG START: LOAD XRA LOOP: LDAX ADC STAX OCR JZ INX INX JMP NUM1: DB DB DB NUM2: DB DB DB NUM3: DB END 0100H CBASE NUM1,NUM2,NUM3 A ;CLEAR ACCUMULATOR B ;LOAD BYTE OF 1ST NO.
808O/808S Assembler Assembler Operation 0117 BA 0118 84 0119 8A 011A AF 011B 32 011C 03 0100 PUBLIC SYMBOLS 27 28 29 NUM2: 30 31 32 33 DB DB DB DB DB NUM3: END OBAH 084H OSAH OAFH 032H DB START NUM1 C.
.
CHAPTER 41 LIST FILE FORMATS Assembly Listing Format The assembly list file is designed for output to a line printer or terminal. Unless otherwise specified, an output page consists of 66 lines, 120 characters wide, and in- cludes three leading and three trailing blank lines, a page header, title line, column headings, and assembly output lines.
List File Formats 808O/808S Assembler 4-2 Assembly Output Line Columns DeSCription 1 Assembler error code. If the assembler encountered a syntax error in this source line, the appropriate error code appears in this column. Otherwise, this column is blank.
8080/8085 Assembler ListFlleFormats Symbol Table Listing The listing of the assembled source code is optionally followed by the symbol table listing. If the NOSYMBOLS control is specified, the symbol table listing is suppressed.
List File Formats 8080/8085 Assembler 4-4 Symbol-Cross-Reference Listing The assembler generates a file of symbol-cross-reference records during assembly pass 1 if the XREF assembler control is selected.
CHAPTER 5 PL/M LINKAGE CONVENTIONS With the relocation feature, it is possible for an assembly language program module to call a procedure originally coded in PL/M. (PL/M procedures can also call assembly language modules.) Linkage between assembly language modules and PL/M procedures should follow the linkage conventions of PL/M.
.
CHAPTER 61 RUNNING YOUR PROGRAM Absolute Programs If your program was assembled using the ASEO location counter, you may be able to load and test your program on the Intellec development system immediately after it is assembled.
.
I I • n CHAPTER 71 ERROR MESSAGES Error Detection and Reporting The assemblers detect and report three classes of errors: source-file errors (including control line errors), run-time errors, and assembler control syntax errors.
Error Messqes 80801808S Assembler 7-2 Code Source M Multiple definition. A symbol is illegally defined because of prior permanent definition. Only symbols defined by SET and MACRO are redefinable. All oc- currences of the multiply-defined item are flagged.
80801808S Assembler Error Messages Assembler Control Enor explanation lIesuge COMMAND ERROR Assembler console command line syntax is illegal, usually due to missing or illegal delimiter or missing parameter.
Error Messages 7-4 8080/8085 Assembler When error number 24 occurs, an additional message is output to the console: FOCC= OOnn where nn has the following meanings: 01 Deleted record. 02 CRC error (data field). 03 Invalid address mark. 04 Seek error. 08 Address error.
1818-118080/8085 Macro Assembler Operator's Manual 9800292-04 REQUEST FOR READER'S COMMENTS The Microcomputer Division Technical Publications Department attempts to provide documents that meet the needs of all Intel product users. This form lets you participate directly in the documentation process.
WE'D LIKE YOUR COMMENTS .•• This document is one of a series describing Intel products. Your comments on the back of this form will help us produce better manuals. Each reply will be carefully reviewed by the responsible person. All comments and suggestions become the property of Intel Corporation.
.
INTEL CORPORATION, 3065 Bowers Avenue, Santa Clara, California 95051 (408) 987-8080 Printed in U.S.A..
デバイスIntel 8085の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Intel 8085をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはIntel 8085の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Intel 8085の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Intel 8085で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Intel 8085を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はIntel 8085の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Intel 8085に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちIntel 8085デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。