American Water Heaterメーカー6510238の使用説明書/サービス説明書
ページ先へ移動 of 28
6510238 January 2005 Supercedes 6510220 Direct Vent Gas Water Heater Installation Instructions and Use & Care Guide To obtain technical, warranty, or service assistance during or after the installation of this water heater, visit our website at: http://www.
2 You can be killed or seriously injured if you don't immediately follow instructions. You can be killed or seriously injured if you don't follow instructions. All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
3 Consumer Informa tion This water heater is design-certified by CSA International as a Category I, direct vented water heater which takes its combustion air from the outside of the structure and exhausts all products of combustion to the outside of the structure.
4 This water heater design has been tested by CSA International and complies with ANSI Z21.10.1, Section 2.35 Flammable Vapors Resistance. Therefore this water heater does not need to be installed 18 inches above the floor unless specifically required by state or local codes.
Important: The water heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the water heater or to lower floors of the structure. Due to the normal corrosive action of the water, the tank will eventually leak after an extended period of time.
6 The Vent terminal is HOT when the water heater is in operation. Do not touch the vent terminal or place any object where contact with the vent terminal may occur. A protective louvered wall or fence is recommended when the hot vent cap is low enough to be touched accidentally (see Figure 5).
7 Manual gas shutoff valve Ground joint union 3 In. Min. Check with local utility for min. height Drip leg Figure 6: Gas Piping Gas Pressure Import ant : The gas supply pressure must not exceed the maximum supply pressure as stated on the water heaters data plate.
8 Nominal Iron Pipe Length of Pipe, Feet Size, in. 1/2 3/4 1 1-1/4 1-1/2 132 278 520 1050 1600 92 190 350 730 1100 73 152 285 590 890 63 130 245 500 760 56 115 215 440 670 50 105 195 400 610 46 96 180.
9 Import ant: Air for combustion and ventilation must not come from a corrosive atmosphere. Any failure due to corrosive elements in the atmosphere is excluded from warranty coverage.
10 9. Position and fasten the inner wall plate to the inside wall using an appropriate fastener for the specific wall construction. Apply silicone sealant between the inner wall plate and the inside wall. 10. Make certain the 5 telescoping pipe has been fully engaged onto the 5 inch elbow.
11 THROUGH THE ROOF VENTING* 1. Center the heater directly under the roof opening. This vent system must be installed vertically only. 2. All the pipes needed to assemble the vent are included in the kit. Do not add to the length of the vent system. The total height is limited to 15 feet on a 50-gallon heater (See Figure 11).
Water System Piping Piping Inst alla tion Piping, fittings, and valves should be installed according to the installation drawing (Figure 12). If the indoor installation area is subject to freezing temperatures, the water piping must be protected by insulation.
Please note the following: DO NOT install this water heater with iron piping. The system should be installed only with piping that is suitable for potable (drinkable) water such as copper, CPVC, or polybutylene. DO NOT use PVC water piping. DO NOT use any pumps, valves, or fittings that are not compatible with potable water.
For protection against excessive pressures and temperatures, a temperature and pressure relief valve must be installed in the opening marked T & P RELIEF VALVE (see Figure 14).
15 Solar Installation If this water heater is used as a solar storage hea ter or as a backup for the solar system, the water supply temperatures to the water heater tank may be in excess of 120°F. A tempering valve or other temperature limiting valve must be installed in the water supply line to limit the supply temperature to 120°F.
Wa ter Hea ter Loca tion · Centrally located with the water piping system. Located as close to the gas piping and vent pipe system as possible. · Located indoors and in a vertical position. Protected from freezing temperatures. · Proper clearances from combustible surfaces maintained and not installed directly on a carpeted floor.
17 OPERATING YOUR WATER HEATER Lighting Instructions Read and understand these directions thoroughly before attempting to light or re-light the pilot. Make sure the tank is completely filled with water before lighting the pilot. Check the data plate near the gas valve control/thermostat for the correct gas.
L.P.G. (Bottled Propane) Models Liquefied Petroleum Gas is over 50% heavier than air and in the occurrence of a leak in the system, the gas will settle on the floor level. Basements, crawl spaces, skirted areas under mobile homes (even when ventilated), closets and areas below ground level will serve as pockets for the accumulation of gas.
Burner Flames Inspect the burner flames through the viewport and compare them to the drawings in Figure 16. A properly operating burner should produce a soft blue flame. Blue tips with yellow inner cones are satisfactory. The tips of the flame may have a slight yellow tint.
A thermocouple is used to determine if a pilot flame is present and will shut off the gas supply to the main burner and the pilot burner if the flame is absent. A high temperature limit switch or ECO (Energy Cut Off) in the tank is used to shut off the unit if the water temperature exceeds 180°F (83°C).
Explosion Hazard If the temperature and pressure relief valve is dripping or leaking, have a licensed plumber correct the problem. Do not plug valve. Do not remove valve.
Replacement P art s Replacement parts may be ordered through your plumber or the local distributor. Parts will be shipped at prevailing prices and billed accordingly. When ordering replacement parts, always have the following information ready: 1. Model, serial and product number.
Replacing the Thermocouple Import ant : Use only a factory authorized thermocouple for replacement. 1. Remove the manifold assembly as directed previously. 2. Remove the retainer clip from the back of the t wo piece wire connector. Remove the t wo piece wire connector from the manifold door.
5. Replace the (6) screws which secure the manifold assembly door to the combustion chamber. Tighten securely. There should be no space between the gasket part of the manifold door and combustion chamber. Do not opera te the w a ter hea ter if the door gasket is not sealed.
25 TROUBLESHOOTING CHART 1. Light pilot 2. Turn temp. dial to desired temperature 3. Check with gas utility company 4. Notify utility-install trap in gas line 5. Clean, locate source and correct 6. Clean, locate source and correct 7. Replace thermocouple 8.
26 TROUBLESHOOTING CHART BURNER FLAME FLOATS AND LIFTS OFF PORTS 1. High gas pressure 2. Orifice too large 3. Flue clogged 4. Cold drafts 1. Check with gas utility company 2. Replace with correct orifice 3. Clean flue and burner-locate source & correct 4.
27 * 1 2 8 7 4 10 9 11 21 25 26 5 3 27 15 17 19 22 19 20 16 6 12 31 13 18 14 32 23 32 REPAIR PARTS ILLUSTRATION LEGEND Special anode rod (see page 20) Temperature and Pressure Relief Valve is required, but may not be factory installed. Pilot Assembly includes Piezo Igniter, thermocouple, and pilot.
28 IMPORTANT: The replacement main burner, orifice, manifold, pilot burner, and the thermostat must be ordered for the proper gas type. © 2005 American Water Heater Company.
デバイスAmerican Water Heater 6510238の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
American Water Heater 6510238をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmerican Water Heater 6510238の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。American Water Heater 6510238の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。American Water Heater 6510238で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
American Water Heater 6510238を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmerican Water Heater 6510238の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、American Water Heater 6510238に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAmerican Water Heater 6510238デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。