Server Inst allation and Integration Guide Using the Boxed Intel ® Xeon Processor and Boxed Intel ® Server Board SE7501CW2.
Intel Server Board SE7501CW2 Installation and Integration Guide Revision History Date Revision Notes Product Code 9/25/03 1 First Draft 10/6/03 2 Second Draft Disclaimers The information contained in .
Intel Server Board SE7501CW2 Installa tion and Integration Guide Table of Contents Introduction ......................................................................................5 Document Ov erview ................................................
Intel Server Board SE7501CW2 Installation and Integration Guide Making Optional Connections to the Server Board ................................. 17 Installing the Seri al B Cable .................................................................. 18 Cable Routing – Intel Se rver Chassis SC5200 .
Intel Server Board SE7501CW2 Installa tion and Integration Guide Introduction Document Overview This guide outlin es the procedures for integratin g an Intel ® Server Platform using an Inte l Server Board SE7501CW2 and Intel Xeon processors.
Intel Server Board SE7501CW2 Installation and Integration Guide Troubleshooting Guide In the unlikely event yo u do encounter issues, the troubleshooting gu ide will help you troubleshoot and identify possible areas of concern regarding the Intel Server Board SE7501CW2.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Hardware Integration The following in stallation procedures enable y ou to prepare a chassis for integration, add the needed components to your server board, and install the server board.
Intel Server Board SE7501CW2 Installation and Integration Guide Important Safety Information Safety Instructions and Information To avoid personal injury or property dama ge, the following safety instructions apply whenever working in side the chassis: 1.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Chassis Preparation and Server Board Installation About the I/O Shield An ATX 2.03-compliant I/O shield is provided wi th your server board. The shield is required by Electromagnetic Interference (EMI) regul ation s.
Intel Server Board SE7501CW2 Installation and Integration Guide Installing Chassis Standoffs If your chassis does not have stando ffs placed as shown, you must rearrange them so t hey match the hol es in the server board. Failure to properly rearrange the metal standoffs may cause the server board to malfunc tion and permanently damage it.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Installing Memory The server board supports only DDR266- compliant DIMMs. The minimum supported memory configuration is 128 MB, using one 128-MB DIMM. The maximum configurable memory size is 8 GB using 4 2-GB DIMMs.
Intel Server Board SE7501CW2 Installation and Integration Guide Installing the Boxed Intel Xeon Processor Choosing the Processor Socket Use these instruction s for installing you r processor instead of the instruction s that came with your boxed processor.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Installing the Retention Mechanism 1. Insert the retention brackets. 2. Tighten the four retention screws. Applying Thermal Grease Apply thermal grease to the processor as shown. Attaching the Heat Sink and Retention Clips 1.
Intel Server Board SE7501CW2 Installation and Integration Guide Installing the Processor Wind Tunnel The following in structions apply to the base Intel Server Chassis SC5200 an d reference chassis installations. Di rect the airflow from the processor wind tunnel toward the rear of the chassis as shown.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Attaching the Wind Tunnel 1. Spread the tabs outward sli ghtly (1a). Lower the wi nd tunnel assembly onto the retention mechani sm (1b). 2. The tabs on the fan assembly (2a) slide into slot s (2b) on the inner side of t 3.
Intel Server Board SE7501CW2 Installation and Integration Guide Making Required Connections to the Server Board Make these connections regardless of the chassi s used.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Making Optional Connections to the Server Board These connections are required only when th e corresponding component is installed.
Intel Server Board SE7501CW2 Installation and Integration Guide Installing the Serial B Cable For the Intel Server Chassis SC5200, yo u can connect the Serial Port B cable to either th e back of the chassis or, on a rack-mount system, to the front of the chassis.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Cable Routing – Intel Server Chassis SC5200 routing guidelines below. sys 1. bles as shown. Floppy and Front Panel Cables Route the floppy drive and front panel cables as shown. Installing the Access Cover 1.
Intel Server Board SE7501CW2 Installation and Integration Guide Installing the Chassis Feet (Pedestal Mode) 1. If you are installing t his server into a rack syst em, skip these steps and go to “Installing in to a Rack (Rack kbench. assis. The th only one set of holes in oot, the middle hole should face toward the front of the chassis.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Finishing Up WARNING tall the chassis access cover before finishing ver” on page 19). An Ins up (see ”Installing the Access Co electrical shock hazar d exists if the chassis access cover is wer.
Intel Server Board SE7501CW2 Installation and Integration Guide Software Installation Updating the BIOS Intel highly recommends tha t you go to th e Intel Server Board SE7501CW2 supp ort Web ite and download and install the latest syste m BIOS update for your operating system.
Intel Server Board SE7501CW2 Installa tion and Integration Guide LANDesk* Client Manager ma nage a computer an d troubleshoot common computer problems. Use Client Mana ger to: nt computers (single, • Client: The client version enables an en d user to view informat ion and manage alerts for a local computer.
Intel Server Board SE7501CW2 Installation and Integration Guide Intel Server Maintenance and Reference Training Tool CD enance and Reference Traini ng Tool CD (Intel SMaRT Tool ) is an providing support in formation to assist with th e maintenance and repair of Intel processor-based server sy stems and accessories.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Thank you for purchasing Intel products! For additional integration reso urces, please visit www.
デバイスIntel SE7501CW2の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Intel SE7501CW2をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはIntel SE7501CW2の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Intel SE7501CW2の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Intel SE7501CW2で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Intel SE7501CW2を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はIntel SE7501CW2の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Intel SE7501CW2に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちIntel SE7501CW2デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。