Dealer: This manual MUST be given to the end user. User: Before using this cylinder, read this manual and save for future reference. For more information regarding Invacare products, parts, and services, please visit www.
HomeFill ® Cylinder 2 Part No 116315 6 WARNING DO NOT USE THIS PRODUCT OR ANY AVAILABLE OPTIONAL EQUIPMENT WITHOUT FIRST COMPLETELY READING AND UN DERSTANDING THESE INSTRUCTIONS AND ANY ADDITIONAL INSTRUCTIONAL MATERIAL SUCH AS OWNER’S MANUALS, SERVICE MANUALS OR INSTRUCTION SHEETS SUPPLIED WITH THIS PRODUCT OR OPTIONAL EQUIPMENT.
TABLE OF CONTENTS Part No 1163156 3 HomeFill ® Cylinder TABLE OF CONTENTS SPECIAL NOTES ............................................... 4 RECEIVING INSPECTION .................................. 4 INTENDED USE .........................................
SPECIAL NOTES HomeFill ® Cylinder 4 Part No 116315 6 SPECIAL NOTES Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage.
SECTION 1—GENERAL GUIDELINES Part No 1163156 5 HomeFill ® Cylinder SECTION 1—GENERAL GUIDELINES WARNING SECTION 1 - GENERAL GU IDELINES contains important information for the safe operation and use of this product. DANGER This product is not intended as a life-sustaining or life-supporting device.
SECTION 1—GENERAL GUIDELINES HomeFill ® Cylinder 6 Part No 116315 6 WARNING DO NOT attempt to repair product. DO NOT immerse product in any kind of liquid. Store product in a clean area when not in use.
SECTION 1—GENERAL GUIDELINES Part No 1163156 7 HomeFill ® Cylinder WARNING NEVER oil or lubricate the cylinder fittings. NEVER use any penetrating oil or lubricant such as WD ‐ 40 or 3 in One.
SECTION 2—FEATURES HomeFill ® Cylinder 8 Part No 116315 6 SECTION 2—FEATURES FIGURE 2.1 Product Diagram Cylinder Fill Port Cylinder Valve 540 Connection Port (with Protective Cap).
SECTION 3—TYPICAL PRODUCT PARAMETERS Part No 1163156 9 HomeFill ® Cylinder SECTION 3—TYPICAL PRODUCT PARAMETERS DIMENSIONS : Weight 5.1 lbs (2.31 kg ) Overall Length 13.
SECTION 4—INSPECTION AND COMPRESSOR INTERFACE HomeFill ® Cylinder 10 Part No 1163156 SECTION 4—INSPECTION AND COMPRESSOR INTERFACE NOTE: Refer to the HomeFill ® Compr essor Owner’s Manual for compressor operating instructions.
SECTION 4—INSPECTION AN D COMPRESSOR INTERFACE Part No 1163156 11 HomeFil l ® Cylinder External Examination 1. Examine the outside of the cylinder for the following .
SECTION 4—INSPECTION AND COMPRESSOR INTERFACE HomeFill ® Cylinder 12 Part No 1163156 Checking Cylinder Pressure WARNING NEVER use tools of any kind to conn ect/disconnect the cylinder and the compressor. Otherwise, severe injury and/or damage may occur.
SECTION 4—INSPECTION AN D COMPRESSOR INTERFACE Part No 1163156 13 HomeFil l ® Cylinder Filling the Cylinder NOTE: For this procedure, ref e r to FIGURE 4.1 thru FIGURE 4.6. 1. Check the cylinder pressure before attempting to fill cylinder .
SECTION 4—INSPECTION AND COMPRESSOR INTERFACE HomeFill ® Cylinder 14 Part No 1163156 FIGURE 4.2 Fillport Covers 5. On the compressor unit, momentarily push DOWN on the outer ring (sleev e) of the connector fillport to reset the connector (FIGURE 4.
SECTION 4—INSPECTION AN D COMPRESSOR INTERFACE Part No 1163156 15 HomeFil l ® Cylinder NOTE: If the outer ring (sleeve) is in the UP position (GREEN dots not visible), the connector fillport will not be able to accept the cylinder fillport.
SECTION 4—INSPECTION AND COMPRESSOR INTERFACE HomeFill ® Cylinder 16 Part No 1163156 NOTE: Refer to Cylinder Fill Ti m e s on page 20 for the length of time it will take to fill the cylinder .
SECTION 4—INSPECTION AN D COMPRESSOR INTERFACE Part No 1163156 17 HomeFil l ® Cylinder 11. After the cylinder is full, press the compressor pow er switch to the Off (O) position (FIGURE 4.
SECTION 4—INSPECTION AND COMPRESSOR INTERFACE HomeFill ® Cylinder 18 Part No 1163156 WARNING The fillport cover on the co nnector fillport and the post valve fillport MUST be replaced after filling and whenever not in use. If either of th e fillport covers are missing contact your healthcare provider before using.
SECTION 5—MAINTENANCE Part No 1163156 19 HomeFil l ® Cylinder SECTION 5—MAINTENANCE 1. After each use, cl ean exterior of the product with a dry , lint free cloth only .
SECTION 6—CYLINDER FILL TIMES HomeFill ® Cylinder 20 Part No 1163156 SECTION 6—CYLINDER FILL TIMES NOTE: All filling times are appr oximate and may vary on environmental conditions.
NOTES Part No 1163156 21 HomeFil l ® Cylinder NOTES.
LIMITED WARRANTY HomeFill ® Cylinder 22 Part No 1163156 LIMITED WARRANTY PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975. This warranty is extended only to the origina l purchaser/user of our products.
LIMITED WARRANTY Part No 1163156 23 HomeFil l ® Cylinder LIMITATIONS AND EXCLUSIONS : THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BE EN REMOVED OR DEFA.
Invacare Corporation www.invacare.co m USA One Invacare Way Elyria, Ohio USA 44036-2125 800-333-6900 Technical Services 800-832-4707 All rights reserved . Trademarks are identified by the symbols ™ and ®. All trademarks are owned by or licensed to Invacare Corporati on or its subsidiaries unless otherwise noted.
デバイスInvacare HF2E540M9の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Invacare HF2E540M9をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはInvacare HF2E540M9の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Invacare HF2E540M9の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Invacare HF2E540M9で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Invacare HF2E540M9を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はInvacare HF2E540M9の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Invacare HF2E540M9に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちInvacare HF2E540M9デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。