MiniView ™ Micro USB 2-Port KVM Switch with Built-in KVM Cables Installation Manual ( GCS52U) ®.
©2003 IOGEAR. All Rights Reserved. PKG-M0073 IOGEAR, the IOGEAR logo, MiniView, VSE are trademarks or registered trademarks of IOGEAR, Inc. Microsoft and Windows are registered trademarks of Microsoft Corporation. IBM is a registered trademark of International Business Machines, Inc.
Thank you for purchasing one of the most feature-rich keyboard, video, and mouse switches on the market. IOGEAR’s MiniView™ Micro switches are first-rate connectivity accessories designed to help reduce the frustration of managing multiple computer systems.
Package Contents Overview Features Requirements Introduction Installation Operation Appendix (HotKey) Specification Troubleshooting Tech Support Radio & TV Interference Statement Limited Warranty .
This package contains: 1 MiniView TM Micro USB 2-port KVM switch 1 User Manual 1 Quick Start Guide 1 Warranty Registration Card If any items are damaged or missing, please contact your dealer.
The MiniView™ Micro USB (GCS52U) KVM switch allows access to two USB computers from a single console (keyboard, monitor, and mouse). This cost-effective way to access two computers, without extra hardware, is highly efficient and easy to use.
- Use one keyboard, monitor and mouse to control two computers - Very compact KVM switch with molded cables for computer connections - Supports Microsoft IntelliMouse and the scrolling wheel on most m.
PS/2 connection USB port VGA connection Computers with a PS/2 mouse and keyboard connection, VGA connection, and an available USB port. Requirements 5.
4 5 12 3 6 4 5 Introduction 1. VGA port for the console monitor 2. PS/2 port for the console keyboard 3. PS/2 port for the console mouse 4. VGA connector to the computer 5.
1 2 3 Before you begin, please turn off the computers you are going to connect to the MiniView™ Micro USB KVM. If you have never installed a USB mouse and Keyboard on your computer before you may need to leave your PS/2 mouse and keyboard attached during the first boot-up after installing the GCS52U.
34 4 5 Step. 2 5.Connect the USB cable (item# 5) that is built into the KVM cable of your MiniView™ Micro to the USB port on your computer. Installation 4.Connect the VGA cable (item# 4) that is built into the KVM cable of your MiniView™ Micro to the VGA port on your computer.
Step. 3 Repeat Step 2 for your second computer. Step. 4 Turn the power of your computers on. To switch between computers, tap the Scroll Lock key twice.
MiniView™ Micro allows you to access the computers through Hot Key combinations from the keyboard. 1. Selecting computers You can toggle between the two computers by pressing and releasing the Scroll Lock key twice: [Scroll Lock]+[Scroll Lock].
To initiate the AutoScan mode, press and release the left Shift key, then press and release the right Shift key: [Left Shift] + [Right Shift]. NOTE: The interval between these two keys should be no more than 0.5 seconds. Once the scanning begins, it continues until you press the [Space Bar] to exit AutoScan Mode.
You can customize the scan interval time with the following Hot Key combination: [Left Shift] + [Right Shift] + [S] + [ n ]. [ n ] represents a number from 1 to 4 which sets the desired scan interval .
y t i v i t c A n o i t c n u F f f O d e t c e l e s t o n s i t r o P ) y d a e t S ( n O r e t u p m o c e v i t c a n a o t d e t c e n n o c s i t r o P g n i h s a l F n i d e s s e c c a g n i .
Specification 14.
Specification Con’d 15.
Troubleshooting 16.
Troubleshooting Con’d 17.
If you need technical support, please check out our IOGEAR Tech Info Library (T.I.L.) at www.iogear.com/support for the latest tips, tricks, and troubleshoot- ing. The IOGEAR T.I.L. was designed to provide you with the latest technical information about our products.
Radio & TV Interference Statement WARNING!!! This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications.
IN NO EVENT SHALL THE DIRECT VENDOR’S LIABILITY FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THE PRODUCT, DISK OR ITS DOCUMEN- TATION EXCEED THE PRICE PAID FOR THE PRODUCT.
Contact info. 23 Hubble • Irvine, CA 92618 • (P)949.453.8782 • (F)949.453.8785 • www.iogear.com ®.
デバイスIOGear GCS52Uの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
IOGear GCS52Uをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはIOGear GCS52Uの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。IOGear GCS52Uの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。IOGear GCS52Uで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
IOGear GCS52Uを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はIOGear GCS52Uの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、IOGear GCS52Uに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちIOGear GCS52Uデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。