JacuzziメーカーJ-210の使用説明書/サービス説明書
ページ先へ移動 of 43
Oz on at or O 3 TB1 230 V AC, 3-Wire Connection USE COPPER CONDUCTORS ONL Y . WIRE SIZE MUST BE APPROPRIA TE PER NEC AND/OR LOCAL CODES 2 1 Flow Switch Hi-limit/Freeze Sensor T emperature Sensor J2 J3 F1 20A 250V SC-20 Ci rc .
Attention New Spa Owner! Congratulations on the purchase of your new Jacuzzi® spa! The following is a list of automated functions performed by your spa.
T able of Contents 1.0 Important Spa Owner Information ..............................................1 2.0 FCC Notice ....................................................................................1 3.0 Important Safety Instructions .............
13.0 W ater Quality Maintenance .......................................................27 13.1 pH Control ....................................................................................27 13.2 Sanitizing ..........................................
page 1 1.0 Important Spa Owner Information Y our Jacuzzi ® 200 series spa is constructed to the highest standards and is capable of providing many years of trouble-free use.
page 2 3.0 IMPORT ANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS CAREFULL Y When installing and using this electrical equipment, basic safety precau- tions should always be followed, including: 1. W ARNING: T o reduce the risk of injury , do not permit children to use this product unless they are closely supervised at all times.
page 3 8. W ARNING: T o Reduce the Risk of Injury: 9. The water in the spa should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and 104°F (40°C) are consid - ered safe for a healthy adult. Lower water temperatures are recom- mended for young children and when spa use may exceed 10 min - utes.
page 4 IMPORT ANT CSA SAFETY INSTRUCTIONS (CANADA ONL Y) When using this electrical equipment, basic safety precautions should always be followed, including the following: 1.
page 5 W ARNING: W ater temperature in excess of 40°C (104°F) may be injuri- ous to your health. W ARNING: Before entering the spa, measure the water temperature with an accurate thermometer . W ARNING: Do not use a spa immediately following strenuous exercise.
page 6 A warning sign is provided in your warranty packet. Please install it at a location near your spa, where it is visible to the user of the spa. For additional or replacement signs please contact your local Jacuzzi spas dealer and reference item num- ber #6530-082.
page 7 4.0 Choosing A Location IMPORT ANT : Because of the combined weight of the spa, water and users, it is extremely important that the base upon which the spa rests be smooth, flat, level and capable of uniformly supporting this weight, without shifting or settling, for the entire time the spa is in place.
page 8 4.2 Indoor Location For indoor installations, be certain to make provisions for proper ventilation. When the spa is in use, considerable amounts of moisture will escape. This can damage certain surfaces over time. If you have any questions regarding the placement or installation of your spa, consult your authorized Jacuzzi dealer .
page 9 6.0 Power Requirements Jacuzzi ® spas are designed to provide optimum performance and flex- ibility of use when connected to the maximum electrical service listed in the tables below . If you prefer , your dealer can perform a minor circuit board modification to allow your spa to accept an electrical service other than the factory setting.
page 10 7.0 Electrical Wiring Instructions IMPORT ANT NOTICE: The electrical wiring of this spa must meet the requirements of the National Electrical Code/USA (NEC) and any applicable state or local codes. The electrical circuit must be installed by a qualified electrician and approved by a local building/electrical inspection authority .
page 1 1 • Convertible 120/240V Operation: The included 120V GFCI cord must be discarded for 240V operation. This spa must be hard wired. Supplying power to either configuration above which is not in accor- dance with these instructions will void both the independent testing agency listing and the manufacturer ’s warranty .
page 12 Figure-B - Control Box 1. T erminal Block 2. Bonding Lug 3. Grounding T erminal TB1 3 2 1 7 8 3 6 2 2 Figure-A Equipment Area 1. Control Box 2. Power Supply Inlet(s) 3. 2-Speed Pump #1 4. Heater 5. Pump Drain Plug 6. 1-Speed Pump #2 7. Optional CD Ozonator (Purchased Separately) 8.
page 13 Congratulations! Y ou are now all set to get your new spa ready to use. Simply follow this step-by-step procedure below , before long, you will be enjoying your first glorious experience in your Jacuzzi J-200 spa. 8.0 Spa Fill Up Procedure FOR BEST RESUL TS, read each step in its entirety before proceeding with that step: 1.
page 14 3. T urn On Power T urn on power to spa at the home’s circuit breaker . The heater and filter/circulation pump will automatically activate. If the control panel LCD flashes water temperature and “ COL ” or “ ICE ”, refer to page 29 for additional information.
page 15 • The heater operates until the water reaches the programmed “set temperature”, then turns off. The heater will reactivate after the water cools to approximately 1.
page 16 CAUTION: never leave your spa unattended for any reason while the cover is open and accessible to small children and animals! 1 1. Turn of f power to the spa at the circuit breaker , then drain spa as outlined in section 12.2 “Draining And Relling” (page 25).
page 17 9.0 Control Functions 9.1 Control Panel A. LED Display: Can display current water temperature (default dis- play), water temperature set point, selected skim- ming/heating mode, and error messages. B. W armer ( + ) Button: Increases water temperature set point.
page 18 9.2 Spa Features And Controls 1 4 2 2 4 4 7 5 9 8 10 3 1. Control Panel 2. Air Controls 3. Filter/Skimmer 4. Therapy Jets 5. Massage Selector (J-220 only). J-210 models use a “Divert-A-Jet” which functions as a diverter in these models. See page 19 for details.
page 19 9.3 Jet/Air Controls Diagram (J-210 & J-220 Models).
page 20 9.4 Jet/Air Controls Diagram (J-230 Models).
page 21 10.0 Operating Instructions The spa control system has automatic functions that operate upon start- up and normal operation to protect the system. Upon power up, the readout displays the following information: 1. Control panel displays current software release (e.
page 22 10.4 Selecting Desired Massage Action (J-210 & J-220 Only) Y our Jacuzzi spa incorporates a “Divert-A-Jet” or “Massage Selector” (page 19) that allows you to custom - ize massage performance between various jet systems by diverting water between them.
page 23 1 1.2 Economy Filtration/Heating Modes (F4-F6) Economy filtration/heating modes are typically selected by customers in warm climates where heat up times are minimized due to higher ambi- ent temperatures.
page 24 allowing another cycle to be selected. T o set a time for the first filtration/heating cycle, simply turn power on to the spa two minutes prior to the desired time. Example: If you desire your first filtration/heating cycle to begin at 10:00 AM turn off power to the spa and turn it back on again at 9:58 AM.
page 25 12.2 Draining and Refilling About every 3 months, you will want to replace the spa’s water . The fre- quency depends on a number of variables including the amount of use, attention paid to water quality maintenance, etc.
page 26 pillows can be returned to the spa when the sanitizer reading drops below 5 ppm. 12.5 Maintaining the Cover Using the Jacuzzi insulating spa cover anytime the spa is not in use will significantly reduce your operating costs, heat-up time and maintenance requirements.
page 27 4. T urn off power to the spa. 5. Remove the synthetic cabinet panel under the control panel and locate the drain plugs on the front of the pump(s), (Figure-A, page 12). Remove plugs to allow water to drain out of pumps and heater . Note: Approximately one to two gallons will be released during this procedure.
page 28 TION OF 7.2 to 7.8. Problems become proportionately severe the fur- ther outside of this range the water gets. A low pH will be corrosive to metals in the spa equipment. A high pH will cause minerals to deposit on the interior surface (scaling).
page 29 14.2 Panel Displays SN2 Open or shorted sensor (heater disabled). The temperature sensor is not functioning. Contact your authorized Jacuzzi dealer or qualified service technician. 14.3 Panel Displays FL1 Pressure switch is not closed when the pump is activated.
page 30 15.0 T roubleshooting Procedures In the event your Jacuzzi ® spa is not working the way it should, please first review all the installation and operating instructions in this manual and check the message on the panel display .
page 31 15.5 No Heat 1. Check thermostat setting (section 10.1 page 21). 2. Keep the spa cover in place while heating. 3. Check the settings to see if your spa is in economy filtration/heating mode (page 23). Should checking the above steps fail to correct the proble m, please call your dealer so that they may arrange service.
page 32 16.0 J-210/J-220 Convertible Circuit Diagram (60Hz) This wiring diagram is used for the J-210/J-220 US/Canada 120/240 V AC (60Hz) convertible power models. Opti onal Ozo nator O 3 Standard 3-Wire 120 V AC Connection (60 Hz, 1 Phase, 15A Service) Use copper conductors ONL Y .
page 33 17.0 J-230 Circuit Diagram (60Hz) This wiring diagram is used for all J-230 US/Canada 240 V AC (60Hz) dedicated power models. OZON A TOR (OPT IONAL ) O 3 GRN TB1 Standard 240 V AC, 3-Wire Connection (60Hz, 1-Phase Service) USE COPPER CONDUCTORS ONL Y .
page 34 Standard 3-Wire 230 VAC Connection (50 Hz, 1 Phase Service) Use copper conductors ONLY. Wire size must be appropriate per NEC and/or local codes.
page 35 19.0 J-230 Export Circuit Diagram (50Hz) This wiring diagram is used for all J-230 Export 230 V AC (50Hz) dedicated power models. Optional Stereo And Power Supply on J-335, J-345 Models Only . Power Supply OZON A TOR (OPT IONAL ) O 3 GRN TB1 230 V AC 3-Wire Connection (50Hz, 1-Phase Service) USE COPPER CONDUCTORS ONL Y .
page 36 Notes.
page 37 Notes.
.
Oz on at or O 3 TB1 230 V AC, 3-Wire Connection USE COPPER CONDUCTORS ONL Y . WIRE SIZE MUST BE APPROPRIA TE PER NEC AND/OR LOCAL CODES 2 1 Flow Switch Hi-limit/Freeze Sensor T emperature Sensor J2 J3 F1 20A 250V SC-20 Ci rc .
デバイスJacuzzi J-210の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Jacuzzi J-210をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはJacuzzi J-210の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Jacuzzi J-210の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Jacuzzi J-210で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Jacuzzi J-210を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はJacuzzi J-210の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Jacuzzi J-210に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちJacuzzi J-210デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。