JacuzziメーカーJ-345の使用説明書/サービス説明書
ページ先へ移動 of 64
OWNER’S MANUAL J-300 ™ Collection J - 315 J - 325 J - 335 J - 345 J - 355 J - 365 J - 375 2530-398W Rev . B.
Attention New Spa Owner! Congratulations on the purchase of your new Jacuzzi ® spa! The following is a list of automated functions performed by your spa.
J-300 T able of Contents 1.0 Important Spa Owner Information.....................................1 2.0 FCC Notice ..........................................................................1 3.0 Important Safety Instructions for all Spa Owners ........
J-300 12.6 Maintaining The Synthetic Cabinet .............................................. 35 12.7 Winterizing ................................................................................... 35 12.8 Restarting Y our Spa in Cold Weather ..........
1 J-300 1.0 Important Spa Owner Information Y our Jacuzzi J-300 Collection spa is constructed to the highest standards and is capable of providing many years of trouble-free use.
2 J-300 3.0 Important Safety Instructions for all Spa Owners READ AND FOLLOW ALL INSTRUCTIONS CAREFULL Y! This spa was manufactured to meet the standards and specications outlined in the “Virginia Graeme Baker Pool and Spa Safety Act” (VGB Safety Act).
3 J-300 un it an d an y m et al e qu i pm en t, m e ta l en cl o su re s of el ec tr ic al eq ui pm e nt , me ta l w at er p i pe , or c o nd ui t wi t hi n 5 fe e t (1 .5 m) of t he u ni t. Ne ve r p er mi t a ny e le ct r ic al a pp l ia nc e, s u ch a s a l ig ht , te le pho ne , r ad io , • te le v is io n, e t c.
4 J-300 Per sons su ff erin g f rom obe sity or a m edic al h ist ory of hear t di sea se, • low or hig h bl ood pre ssur e, circ ula tory sys tem pro blem s, diab ete s, inf ecti ous dis eas es o r im mun e de ci ency syn dro mes shou ld cons ult a phy sici an befo re usin g a spa .
5 J-300 10. CAUTION: TO DECREASE RISK OF PRODUCT DAMAGE. Maintain water chemistry in accordance with manufacturer ’s • instructions. Proper chemical maintenance of spa water is necessary to maintain • safe water and prevent possible damage to spa components.
6 J-300 3.1 Entrapment Risk The Consumer Products Safety Commission/USA has reported that users of pools and spas have become entrapped (stuck) to drain and/or suction ttings causing death, drowning, or serious injury (see diagram below).
7 J-300 3. ! DANGER: RISK OF SEVERE INJUR Y OR DROWNING! Body entrapment: May occur when part of the torso becomes entrapped, inserted or sucked into a suction or outlet opening. Never allow children to play or get near the suction ttings, suction • covers, lter , lter lid or skimmer assembly .
8 J-300 3.3 Important Additional CSA Safety Instructions (Canada Only) When using this electrical equipment, basic safety precautions should always be followed, including the following: 1.
9 J-300 4.0 Choosing A Location IMPORT ANT : Because of the combined weight of the spa, water and users, it is extremely important that the base upon which the spa rests be smooth, at, level and capable of uniformly supporting this weight, without shifting or settling, for the entire time the spa is in place.
10 J-300 4.1 Outdoor Location In sel ecting the ideal outdoor location for your spa, we suggest that you take into consideration: The proximity to changing area and shelter (especially in colder • weather). The pathway to and from your spa (this should be free of debris so • that dirt and leaves are not easily tracked into the spa).
11 J-300 Proper V entilation: an Engineer or authority competent enough to understand the necessary provisions needed to vent moist or heated air and air associated with chemical odors outdoors.
12 J-300 5.0 General Electrical Safety Instructions Y our new Jacuzzi spa is equipped with a “state-of-the-art” equipment system. It contains the most advanced safety and self-protective equipment in the industry . Nonetheless, this spa must be installed properly to insure dependable usage.
13 J-300 .
14 J-300 230V/20A* 230V/3.
15 J-300 7.0 Electrical Wiring Instructions IMPORT ANT NOTICE: The electrical wiring of this spa must meet the requirements of the National Electrical Code/USA (NEC) and any applicable state or local codes. The electrical circuit must be installed by a qualied electrician and approved by a local building/ electrical inspection authority .
16 J-300 ANSI/NFP A 70. The disconnecting means must be readily accessible to the spa’s occupant but installed at least 5 feet (1.5m) from spa water . 7. The electrical circuit supplied for the spa must include a suitable ground fault circuit interrupter (GFCI) as required by NEC/USA Article 680-42.
17 J-300 Figure B Control Box TB1 3 2 1 1. T erminal Block 2. Bonding Lug 3. Grounding T erminal GRN WHT WHT BLK BLK BLK RED 1 2 3 Figure-C TB1 to Circuit Board Power In GRN WHT WHT BLK BLK BLK RED RE.
18 J-300 8.0 Spa Fill Up Procedure For best results, read each step in its entirety before proceeding with that step. 1. Prepare The Spa For Filling Clear all debris from the spa. (Although the spa shell has been • polished at the factory , you may want to treat it with a specially formulated spa cleaner .
19 J-300 5. Add Start-Up Chemicals Add the spa water chemicals as recommended by your authorized Jacuzzi dealer . See Section 13.0 “Water Quality Maintenance” (page 36) for general guidance. W ARNING: RISK OF POISONING OR DEA TH. Never leave chemicals opened and accessible to anyone.
20 J-300 8. Place Cover On Spa Keeping the insulating cover in place anytime the spa is not in • use will reduce the time required for heating, thereby minimizing operating costs. The time required for initial heat-up will vary depending on the • starting water temperature.
21 J-300 10. Leave spa cover open during this step to allow excessive chemical vapors to exit spa, protecting pillows and plastic knobs from chemical attack.
22 J-300 W ARNING: RISK OF PERSONAL INJUR Y . T o decrease the risk of injury , entrapment or drowning, • never leave your hot tub unattended for any reason, es- pecially if while the cover is open and accessible to small children and animals! T o decrease the risk of • contracting a waterborne illness (e.
23 J-300 9.0 Control Functions 9.1 Control Panel A. LED Display: Can display current water temperature (default display), water temperature set point, selected filtration/ heating mode, and error messages. B. Warmer ( ) Button: Increases water temperature set point.
24 J-300 9.2 General Spa Features And Controls 1 7 8 11 2 2 2 2 2 5 5 3 4 6 13 13 13 13 15 15 14 5 10 10 10 12 9 6 17 17 17 16 16 16 16 Control Panel 1. T oggle Air Controls 2. Filter/Skimmer Grill 3. PowerPro MX Jets 4. Therapy Jets 5. Massage Selector V alves 6.
25 J-300 10.0 Operating Instructions The spa control system has automatic functions that operate upon start-up and normal operation to protect the system. Upon power up, the readout displays the following information: 1. Control panel displays current software release (e.
26 J-300 Pressing this button activates the waterfall, footwell light, lighted cup holders, and backlit pillows lights in unison as follows: high - medium - low - off. Note: Lights automatically turn off after 2 hours.
27 J-300 10.6 Selecting Desired Massage Action All models incorporate a massage selector valve that allows you to customize the massage and performance by diverting water between various jet systems within the spa. Simply turn valve to positions A, B or C to divert water pressure to various jet groups.
28 J-300 1 1.0 Automatic Filtration Cycles Y ou r ne w s pa i nc lu d es a 2 4- h ou r ci rc u la ti on p um p w hi ch l te rs t h e wa te r co nt i nu ou sl y . Th e c ir cu la ti o n pu mp d r aw s wa te r thr ou gh th e sk im m er b ag and one of two lter cartridges to effectively remove small debris in your spa.
29 J-300 F0 5 minutes of ltration per day (one 5 minute “Blow-Out” cycle every 24 hours to purge all plumbing lines) F1 1 hour of ltration per day (one 30-minute cycle every 12 hours); This is the factory default setting.
30 J-300 12.0 Spa Maintenance Proper and regular maintenance of your spa will help it retain its beauty and performance. Y our authorized Jacuzzi dealer can supply you with all the information, supplies, and accessory products you will need to accomplish this.
31 J-300 An optional chemical feeder is available through your authorized Jacuzzi dealer that installs under the lter cap (#2472-673). Always remove the chemical feeder cap and feeder (when used) during the lter cleaning process by turning the cap handle counterclockwise.
32 J-300 E Lift unthreaded lter cartridge from skimmer well. F If used, remove the chemical feeder as instructed prior to rinsing the lter cartridges. Rinse debris from lter pleats on each cartridge using a garden hose and high pressure nozzle.
33 J-300 Periodically , the lter cartridge will need a more thorough cleaning to remove imbedded oils and minerals. For this, we suggest cleaning as illustrated in step “F”, followed by soaking.
34 J-300 12.3 Pillow Care Remove and clean the headrest pillows as needed with soapy water using a cloth or soft-bristle brush. Always remove the pillows when adding chemical shock treatment to the spa water . When the sanitizer reading is below 4.0 ppm, pillows can be reinstalled.
35 J-300 B. Additional Care and Maintenance Instructions: 1. Debris can accumulate on the spa cover . Removal of snow or other debris will help to avoid breakage of the foam cores. 2. Be sure to lock the cover straps to secure the cover from unwanted or accidental entry .
36 J-300 CAUTION: TURN OFF POWER TO HOT TUB! 1. T urn off power to the spa. 2. Follow the directions on page 33 for draining the spa. 3. T urn the massage/diverter selector(s) into the middle combo position to allow the water in the plumbing lines to drain, see page 27 .
37 J-300 hot tub investment. For specic guidance on maintaining water quality , consult your Authorized Jacuzzi dealer who can recommend appropriate chemical products for sanitizing and maintaining your hot tub. W ARNING: F AILURE TO MAINT AIN W A TER QUALITY WILL: Increase risk of contracting a waterborne illness (e.
38 J-300 W ARNING: OR ENTRAPMENT! Never leave your hot tub unattended for any reason while t.
39 J-300 14.3 Panel Displays ICE Freeze Protection - A potential freeze condition has been detected. No action is required. Jets Pump 1 and heater will activate to circulate and warm water through the plumbing until spa is out of danger . See “Winterizing” (page 3 5 ).
40 J-300 Contact your authorized Jacuzzi dealer or qualied service technician. T o correct condition: Remove the spa's cover and allow your spa to cool down. • Program the lter settings for Economy Mode (page • 28). Raise water temperature setting to cancel Summer Logic condition (page 3 8 ).
41 J-300 1. Jets may all be closed. V erify all jets are in the open “on” position (Sec. 10.5, page 2 6). 2. Pump may not be properly primed. This can happen after the spa is drained and relled. Press the JETS 1 button on the control panel several times, never leaving the motor running for more than 5 to 10 seconds at a time.
42 J-300 16.0 Circuit Board Diagrams Dedicated Power Models (60 Hz) This wiring diagram is used for all North American, 240V (60 Hz) dedicated power models.
43 J-300 (60 Hz) This wiring diagram is used for all North American 120/240V 60 Hz convertible power models.
44 J-300 This wiring diagram is used for all Export 230 V AC 50 Hz spa models.
45 J-300 16.4 Export J-315 and J-325 Models (50 Hz) This wiring diagram is used for all Export 230 V AC 50 Hz spa models. Ozonator Optional O 3 TB1 230 V AC, 3-Wire Connection (50Hz, 1-Phase Service) USE COPPER CONDUCTORS ONL Y .
46 J-300 17.0 Optional Stereo Receiver Functions 17.1 Stereo Receiver Control Functions SA T INFO AS-PS XBA S 2 ZONE SUBW BAND S E A R C H INT RPT RD M A UD IO ENTER MODE MULTI - ENVIRONMENT PLA YE R .
47 J-300 C. T o navigate through the menus use the ( ) or ( ) buttons or press the MENU button repeatedly . D. T o adjust the selected menu item, press the VOLUME Up (7) or Down (8) buttons.
48 J-300 SA T INFO AS-PS XBA S 2 ZONE SUBW BAND S E A R C H INT RPT RD M A UD IO ENTER MODE MULTI - ENVIRONMENT PLA YE R TOP MENU AQ-CD-3 9 8 7 6 2 3 4 1 10 5 1 1 12 13 14 18 15 16 17 19 20 21 22 VOLU.
49 J-300 MIDDLE (Middle Level) : User has 5 seconds to use the V olume Up or Down button to adjust the desired Middle level range from -6 to +6. MID-CFQ (Middle Cent er Frequency) : User has 5 seconds to use the V olume Up or Down button to adjust the desired Middle Range Center Frequency to 500 Hz, 1 KHz, 1.
50 J-300 SA T INFO AS-PS XBA S 2 ZONE SUBW BAND S E A R C H INT RPT RD M A UD IO ENTER MODE MULTI - ENVIRONMENT PLA YE R TOP MENU AQ-CD-3 9 8 7 6 2 3 4 1 10 5 1 1 12 13 14 18 15 16 17 19 20 21 22 F AD.
51 J-300 14. While in seek mode the stereo unit will automatically select 6 strong stations and store them in the current band.
52 J-300 SA T INFO AS-PS XBA S 2 ZONE SUBW BAND S E A R C H INT RPT RD M A UD IO ENTER MODE MULTI - ENVIRONMENT PLA YE R TOP MENU AQ-CD-3 9 8 7 6 2 3 4 1 10 5 1 1 12 13 14 18 15 16 17 19 20 21 22 20 .
53 J-300 The system can only display the rst 8 letters of ID3 tags. If the recorded information is longer than 8 letters, text will scroll to the left once, then the 8 rst letters will be displayed. If specic info has not been recorded on an MP3 disc, NO FOLD, NO TRK, NO TL T , NO ALBM, NO ART will display .
54 J-300 General Power ................................................................................ DC 1 1.5 -14.4V Pre Output V oltage ................................................................................ 5V Current Consumption .......
55 J-300 A. 1. There are three different play methods as following: Press the M2 button more than 3 seconds during playing an MP3/ • WMA disc for “intro play” to all les of the current folder .
56 J-300 2. File/Folder Repeat play : Press the M3 button more than 3 seconds during playing MP3/WMA • d is c fo r “ re p e a t pl a y ” fo r al l l e s of t h e cu r r en t f o ld er a n d ke e p on r e p ea t p la yi ng th e c u r re nt f ol de r un ti l “ re pe a t pl ay ” is d i s ab le d.
57 J-300 ICON DESCRIPTION FOLDER ICON FILE ICON TRACK ICON ARTIST ICON ALBUM ICON Before going through the check list, check wiring connection.
58 J-300 ERROR Mechanism Error Press the eject button to correct the problem. If the error code does not disappear , consult your nearest service dealer Disc Error Maybe disc dirty/disc scratched/disc upside down Replace the disc 17.5 Standard Wireless Remote Control Functions A remote control is supplied on all spas with the optional audio system.
59 J-300 B. Bonding the Remote and Stereo If your remote does not operate the stereo, you may need to bond them by pressing on of the following methods: Press and hold the MUTE button for 5 seconds or; • Press the four buttons MODE, MUTE, BAND/SEARCH, and T OP • buttons at the corners one by one clockwise.
60 J-300 17.7 Wireless Remote Battery Replacement Procedure 1. T urn the remote unit over and locate the battery door (Figure A). 2. Rotate the battery door , with a coin, counterclockwise until the dot aligns with the Open arrow (Figure B). 3. Remove battery door using coin to pry the door upward (Figure C).
デバイスJacuzzi J-345の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Jacuzzi J-345をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはJacuzzi J-345の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Jacuzzi J-345の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Jacuzzi J-345で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Jacuzzi J-345を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はJacuzzi J-345の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Jacuzzi J-345に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちJacuzzi J-345デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。