Johnson ControlsメーカーTCGD30の使用説明書/サービス説明書
ページ先へ移動 of 14
TECHNICAL GUIDE SPLIT -SYSTEM AIR CONDITIONERS 13 SEER – R-4 10A – 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS) Due to contin uous produc t improvement , specifica tions are subject to change without notice. Visit us on the web at www .
415571-UTG-C-0309 2 Johnson Controls Unitary Products All dimensions are in inche s. They are subject to ch ange with- out notice. Certified dimensions will be provi ded upon request.
415571-UTG-C-0309 Johnson Controls Unitary Products 3 PROCEDURES: 1. Unit factory charge listed on the un it nameplate includes re frigera nt for the condenser , the smallest evaporator and 15 feet of interconnecting line tubing. 2. V erify the TXV and addit ional charge required for specific evaporator coil in the system using the above table.
415571-UTG-C-0309 4 Johnson Controls Unitary Products — = Not applicable. COOLING CAP ACITY - With A ir Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL W RA TED CFM NET MBH SEER EER TOT AL SENS. 13 SEER AC WITH MA TCGD30S4(3,4)S1 MA12B 17 FC/MC35B 1000 29 .
415571-UTG-C-0309 Johnson Controls Unitary Products 5 COOLING CAP ACITY - Up flow , Downflow & Horizont al Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (Min.-max.) W RA TED CFM NET MBH SEER 1 EE R TOT AL SENS. TCGD30S4(3,4)S1 800 - 1200 14 FC/MC/PC32 1000 29.
415571-UTG-C-0309 6 Johnson Controls Unitary Products COOLING CAP ACITY - With High Efficiency Motor Furnaces UNIT MODEL FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM Net MBH SEER EER TOT AL SENS. 13 SEER HP WITH V ARIABLE SPEED FURNACES 2 TCGD30S4(3,4)S1 T*(8,L)X*A12 FC/MC/PC32A 14 970 29.
415571-UTG-C-0309 Johnson Controls Unitary Products 7 TCGD48S4(3,4)S1 T*(8,L)X*C16 FC/MC/PC48C 21 1600 48.0 34.4 13.30 1 1.00 T*(8,L)X*C20 FC/MC/PC48C 21 1660 48.0 34.4 13.20 1 1.00 T*9X*C16 FC/MC/PC48C 21 1565 48.0 34.8 13.10 1 1.00 T*9X*C20 FC/MC/PC48C 21 1615 48.
415571-UTG-C-0309 8 Johnson Controls Unitary Products ACCESSORIES Refer to Price Manual for specific model numbers. OFF CYCLE TIMER DELA Y - Provides a 5-minute off cycle to prevent rapid recycling of th e compressor.
415571-UTG-C-0309 Johnson Controls Unitary Products 9 Multipliers for determin ing the perf orma nc e with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (between .
415571-UTG-C-0309 10 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those liste d (bet ween.
415571-UTG-C-0309 Johnson Controls Unitary Products 11 Multipliers for determin ing the perf orma nc e with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (between.
415571-UTG-C-0309 12 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those liste d (bet ween.
415571-UTG-C-0309 Johnson Controls Unitary Products 13 Multipliers for determin ing the perf orma nc e with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (between.
Subject to change without notice. Printe d in U.S.A. 415571-UTG-C-0309 Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Supersedes 415571-UTG-B-0708 Johnson Controls Unitary Product s .
デバイスJohnson Controls TCGD30の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Johnson Controls TCGD30をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはJohnson Controls TCGD30の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Johnson Controls TCGD30の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Johnson Controls TCGD30で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Johnson Controls TCGD30を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はJohnson Controls TCGD30の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Johnson Controls TCGD30に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちJohnson Controls TCGD30デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。