JotulメーカーGF 600 DVの使用説明書/サービス説明書
ページ先へ移動 of 28
1 Installa tion and Oper a tion Instructions Jøtul GF 600 D V Firelight Direc t V ent Gas Heater IF THE INFORMA TION IN THESE INSTRUC- TIONS ARE NOT FOLL O WED EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CA USING PROP- ERTY D AMAGE, PERSONAL INJUR Y OR LOSS OF LIFE.
2 W elc ome to J ø tul... C ongra tulations on the purchase of your new GF 600 DV F irelight Gas Heater . W e at Jøtul are glad you’ve made the decision to warm your hearth with a Jøtul product . Y our new Firelight exemplifies over 150 years experience as the world’ s largest manufacturer of solid fuel burning appliances.
3 T able of C ontents Service T ools .............................................. 3 Specifications ........................................... 4 General Inf ormation ............................... 5 Safety Inf ormation .............................
4 GF 600 D V Fir elight Specifications Input Rates Natur al Gas 40,000 BTU /hr . maximum input 28,600 BTU /hr . minimum input Propane 40,000 BTU /hr . maximum input 30,900 BTU /hr . minimum input Inlet P ressure: MI N M AX Natur al Gas: 5.0 W C (1.24 kP a) 7.
5 Gener al Inf ormation THIS H EA TER MUS T B E IN S T ALLED AND MAIN- T AI N ED BY A QU ALIFI ED SERVICE AGENCY . The installation and repair of this appliance must be done by a qualified service person.
6 Location In selecting the location, the aesthetic and func- tional use of the appliance are primary concerns. However , proper venting systems and access to the fuel supply are also important issues. Due to the high surface tempera tures , y ou must also consider the pro ximity of traf fic areas , furniture, draperies , etc.
7 ALC OVE: MAXIMUM AL C OVE DEP T H: 24” (61 cm) MIN IMUM ALC O VE WI DT H: 44” (112 cm) MIN IMUM CEI LI NG H EIGHT : 64” (163 mm) Sto ve and V ent Clearance Requirements Minimum Clearances from the Stov e to C ombustibles: See Figs.
8 V ent Restric tion The GF 600 DV F irelight includes two rectangular E xhaust Restrictor plates and one square Air Inlet Restrictor Plate as shown in Figur e 5.
9 EXHAUST RESTRICTORS REQUIRED ON ALL CO-LINEAR INST ALLA TIONS. AL W A YS MAINT AIN THE PROPER CLEARANCES TO COMBUSTIBLES. Co-linear Hearthmount Installation The GF 600 D V Firelight can be installed using a Hearthmount Co-linear Flexible V ent System, designed f or installation into a solid fuel burning masonry fireplace.
10 Simpson Dura - V ent Chimne y Co nversion Kit The GF 600 DV F irelight is approved f or use with Simpson Dur a-ven t Chimney Kits as shown in Figure 8. These installation require- ments must be followed: In masonry chimney a fire-clay liner must be present the enti re length of the chimne y .
11 ANY VENTING WIT H A VERTIC AL R ISE MUST TERMI- NA TE (END) WI TH IN T HE SHADED AR EA. R estrictors required on: • All Co-linear (flex pipe) • All coaxial (rigid pipe) venting higher than 7 feet. • Both restrictors must be used when restriction is required.
12 C L Horizontal T ermination The horizontal termination cap must maintain a 3” clearance to any overhead c ombustible projections that are 2 1/2” or less. It must also maintain a 12” clearance from projections that exceed 2 1/2” . See Figure 9.
13 3 76 mm 12 305 mm 2 1/2 64 mm Figure 12. Horizontal T ermination Clearance * As specified in CGA B149 Installation C odes. Note: Local C odes and Regulations ma y requir e dif fe rent clearances.
14 Con version Kit (LPG #154391, NG # 154392) T ools required: • 1/4” nut driver • 1/2” & 13 mm open end wrench or deep-well socket • T orx T20 or slotted screwdriv er • 7/16” open e.
15 Figure 12. Remove the Air Divider and Log Support . Gas Conv ersion Procedure All numbers in ( ) ref er to the exploded view on page 25 of this manual. 1. T urn off gas supply to the stove. 2. R emove the top griddle (7). 3. Locate the two set screw s near the top of each side casting (3, 8).
16 17. Replace the v ariable regulator . Using a T orx T -20 screwdriv er , remo ve the thr ee specialty screw s from the HI/LO r egula tor on the fron t of the valv e. Note: T o help identify which screw s to remo ve, ref er to the new regula tor in the kit.
17 Leak test: 1. Mix a 50-50 solution of wa ter and dish soap. 2. Light appliance- see lighting instructions on page 22 of this manual or on the stove’ s rating pla te. 3. Brush or spra y all joints and connections with the soapy wa ter solution. 4.
18 High Altitude Adjustment When installing the GF 600 DV Fir elight gas stove in high altitude situations ( above 2500') it becomes necessary to compensate f or the thinner air (less volume of o xygen per cubic f oot). High altitudes af fect the atmospheric pressu re and heat value of gaseous fuels.
19 Air Shutter Adjustment / Flame Appear ance The GF 600 D V FIR ELIGHT gas stove is shipped from the fa ctory equipped as a NA TURAL GAS S T OVE. If the stove is con v erted for propane, it will be neces- sary to adjust the air shutter on the burner tube to achieve the proper gas to air mixture.
20 Install the Log Set The four -piece log set is packaged in bubble wr ap inside the firebo x. Do not handle the log set with your bare hands. Alway s wear glov es to prev ent skin irrita- tion from the ceramic fibers. 1. Remov e the Grille and T op Plate from the stov e.
21 Optional C ontrols W all Thermostat Use only a 750 millivolt DC two-wire circuit ther- mostat, placed in the same room as the heater , typically 5’ off the floor . Avoid dra fty ar eas or any are a that may af f ect the accuracy of the thermo- stat .
22 3. BURN ER AD JUST MEN T : The Jøtul GF 600 DV Fir elight gas stove is equipped with a variable gas con trol valve that provides easy adjustment of the flame height, appearance, and heat output . T o adjust the flame between the H I and LO W setting , r otate the H I/LO W knob, located in the center of the valv e face.
23 C onnect the W iring Harness 1. Locate the switch brack et on the back of the stov e, below the burner con trol switch. 2. R emove the f our 1/4” hex head screws that secure the switch br acket to the lef t rear shroud. Ca refully pull the switch br acket awa y from the sto ve.
24 Maintenance The GF 600 D V Firelight gas stove and its v enting system should be inspected bef ore use and at least annually by a qualified service technician. IMPORT ANT: ALWA YS TURN OFF THE GAS SUPPL Y T O THE ST O VE BEFORE ANY SERVICE WORK IS PERFORMED ON THE ST O VE.
25 1 2 3 4 5 6 7 8 4 9 10 11 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 F ir elight GF 600 DV P ar ts Identification.
26 * NO T SHOWN in exploded view diagram Cast Iron P art Matte Black Blue Black Ivory Green Indigo 1 Left Door 10332192 103416 103444 10332132 10332136 2 Right Door 10332092 103415 103443 10332032 103.
27 7. Push in gas control knob slightly and turn counter- clockwise to “PILOT”. 8. Push in control knob all the way and hold in. Immediately light the pilot by triggering the spark ignitor (push the red button repeatedly) until pilot lights. Continue to hold the control knob in for about one minute after the pilot light s.
28 notes: This appliance must be installed in conformance with local and national building regula tions. It is important that the these instructions be read and understood befor e beginning the installation. Jøtul pursues a policy of con tinual product developmen t.
デバイスJotul GF 600 DVの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Jotul GF 600 DVをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはJotul GF 600 DVの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Jotul GF 600 DVの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Jotul GF 600 DVで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Jotul GF 600 DVを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はJotul GF 600 DVの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Jotul GF 600 DVに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちJotul GF 600 DVデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。