AMXメーカーWall Docking Station MVP-WDSの使用説明書/サービス説明書
ページ先へ移動 of 38
Installation Guide Touch Panels & Accessories MVP-WDS Wall Docking Station for MVP-7500/8400 Modero ® ViewPoint ® Wireless Touch Panels Last Revised: 12/15/200 8.
AMX Limited Warranty and Disclaimer AMX warrants its products to be free of defects in material and workmanship under n ormal use for three (3) years from the date of purchase fr om AMX, with the foll.
FCC Information This device complies with Part 15 of the FCC Rules. Operati on is subject to the followi ng two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference rece ived; in cluding inte rference that may cause undesi red operation.
.
Table of Contents i MVP-WDS Wall Docking Station for MVP Panels Table of Contents MVP-WDS Wall Docking Station & CB-MVPWDS Rou gh-In Box ......................... 1 Overview .............................. ......................... ................
ii MVP-WDS Wall Docking Station for MVP Panels Table of Contents.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 1 MVP-WDS Wall Docking Station for MVP Panels MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box Overview The MVP-WDS W all/Flush Mount Docking Station (FIG. 1) pro vides a surface-installed docking location.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 2 MVP-WDS Wall Docking Station for MVP Panels Specifica tions MVP-WDS Specifications Dimensions (HWD): • 8.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 3 MVP-WDS Wall Docking Station for MVP Panels MVP-WDS docking station co nnector locations FIG. 2 shows the layout of the connectors on the right side of the MVP-WDS. LED Indicators The two LEDs located within the security release pushbutton on the front panel (FIG.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 4 MVP-WDS Wall Docking Station for MVP Panels Installation MVP-WDS wall-docking stations can be installed either the CB-MVPWDS or othe r solid surface en vironment using one of the two mounting o ptions: drywall clips or solid surface s cr ews, as described in the following sub-sections.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 5 MVP-WDS Wall Docking Station for MVP Panels 2. Using either nails or screws, fasten the rough-in box to the stud through the fiv e Stud Fastening Holes. 3. Remove the wiring knockouts from the right side of the rough-in box to accommodate cabling to the MVP-WDS.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 6 MVP-WDS Wall Docking Station for MVP Panels 4. Close the battery cov er and disconnect the power connector to remo ve po wer from the unit and maintain the support cradle in the forward position.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 7 MVP-WDS Wall Docking Station for MVP Panels 8. Press down on the Security Latch to allow it to go through the top op ening. 9. Grasp the top rim of the faceplate and carefully slide it over the cradle (at an angle) until the faceplate is completely removed from the WDS (FIG.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 8 MVP-WDS Wall Docking Station for MVP Panels Installing the MVP-WDS in a CB- MVPWDS Rough-In Box The rough-in box must be mounted prior to continuing this section. Refer to the Installing the CB-MVPWDS Rough-In Box section on page 4 for de tailed pre-wall installation instructions.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 9 MVP-WDS Wall Docking Station for MVP Panels 3. Using a grounded Phillips-head screwdriv er , insert and secure four #6-32 Mounting Screws (n.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 10 MVP-WDS Wall Docking Station for MVP Panels 2. Thread the USB and Power cables through the surface opening, leaving enough slack in the wiring to accommodate re-positioning of the unit. 3. Connect the 2-pin power connector and USB cables to the WDS.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 11 MVP-WDS Wall Docking Station for MVP Panels 6. T ighten all four drywall clip sets (scre ws and clips) until both Mounting T abs are securely fastened and flush against the wall.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 12 MVP-WDS Wall Docking Station for MVP Panels 2. Thread the USB and Power cables through the surface opening, leaving enough slack in the wiring to accommodate any re-positioning of the unit. 3.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 13 MVP-WDS Wall Docking Station for MVP Panels 7. Insert and secure four #4-40 Mounting Screws ( not included) into their corresponding holes located along the sides of the WDS (using a grounded Phillips-head screwdri ver) until the WDS is secured and is flush against the wall.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 14 MVP-WDS Wall Docking Station for MVP Panels 7. Apply power to the MVP-WDS by connecting the terminal end of the power cable to the po wer supply . 8. Press the Cradle Acti vation pushb utton to cause the MVP Support Cradle to angle backwards and lie flush against the main unit.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 15 MVP-WDS Wall Docking Station for MVP Panels Connecting and Usi ng USB In put Devices on the Stations The MVP-WDS can have up to two USB input de vices connected for use on the MVP panel’ s different firmw are and TPD4 panel page s.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 16 MVP-WDS Wall Docking Station for MVP Panels Securing an MVP Panel to an MVP-WDS 1. Place the MVP-WDS on a flat and lev el surface. 2. Provide po wer to the MV P-WDS (refer to the P owering the MVP-WDS section on page 14).
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 17 MVP-WDS Wall Docking Station for MVP Panels Removing an MVP Panel from an MVP-WDS The MVP security feature enables a security code that is entered into an on-screen password keypad. This password is conf igured within the MVP panel’ s P assword Setup page.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 18 MVP-WDS Wall Docking Station for MVP Panels Undock-<USER> Stri ng When the MVP is removed from the docking station (undocked), the undock-<user> string is sent to the NetLinx Master .
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 19 MVP-WDS Wall Docking Station for MVP Panels Installing the MVP-WDS-SK Silver Conversion Kit The VP-WDS-SK Silver Con version Kit (FG5965-22.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 20 MVP-WDS Wall Docking Station for MVP Panels 7. Disconnect the 2-pin mini-Phoenix connec tor from the side of the docking station to re mov e power from the unit and maintain the support cradle in this angled position.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 21 MVP-WDS Wall Docking Station for MVP Panels 14. Press downward on the Security Latch (tow ards the pushbutton) to get it to go through the top opening and allow the faceplate’ s remov al. 15.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 22 MVP-WDS Wall Docking Station for MVP Panels 4. Carefully remov e the cradle piv ot’ s attachment screw and place it aside for later re-attachment.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 23 MVP-WDS Wall Docking Station for MVP Panels 8. Carefully place the first circuit board aside and rota te the black piv ot combo unit over to expose the second circuit board attached to the backside of the unit ( B in FIG.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 24 MVP-WDS Wall Docking Station for MVP Panels 5. Use the scre wdriv er to install one of the previous ly remo ved MVP Support Cradle Securing scre ws to the securing plate (shown in FIG. 24 on pa ge 22).
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 25 MVP-WDS Wall Docking Station for MVP Panels Open the Battery Compartment by pressing down on the Battery Compartment Latch and then pulling the cov er outwards.
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box 26 MVP-WDS Wall Docking Station for MVP Panels.
Upgrading the Docking Station Firmw are 27 MVP-WDS Wall Docking Station for MVP Panels Upgrading the Docking Station Firmware The following accessory de vices are firmware upgradeable: MVP-TDS T a.
Upgrading the Docking Station Firmware 28 MVP-WDS Wall Docking Station for MVP Panels Step 2: Upgrade t he Docking Station firmware v ia USB 1. Configure the panel for a USB Connection T ype. 2. Prepare NetLinx Studio for comm unication to the panel v ia a V irtual Master .
Upgrading the Docking Station Firmw are 29 MVP-WDS Wall Docking Station for MVP Panels 10. Click the Reboot Device checkbox. This cause s the touch panel to reboo t after the firmware update process is complete. The r eboot of the panel can take up 30 seconds after the f irmwar e pr ocess has finished.
Upgrading the Docking Station Firmware 30 MVP-WDS Wall Docking Station for MVP Panels Although firmware u pgrades can be don e over wirele ss Ethernet; it is recommended that firmware KIT files be transfer red over a direct USB connection and only when the panel is connected to a power supply .
Upgrading the Docking Station Firmware 31 M VP-WDS Wall Docking Station for MVP Pan els.
12/08 © 2008 AMX. All rights reserved. AMX a nd the AMX logo are regist ered trademarks of AMX. AMX rese rves the right to alter specific ations without no tice at any time. It’s Your World - Take Con trol™ 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA • 800.
デバイスAMX Wall Docking Station MVP-WDSの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
AMX Wall Docking Station MVP-WDSをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAMX Wall Docking Station MVP-WDSの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。AMX Wall Docking Station MVP-WDSの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。AMX Wall Docking Station MVP-WDSで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
AMX Wall Docking Station MVP-WDSを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAMX Wall Docking Station MVP-WDSの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、AMX Wall Docking Station MVP-WDSに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAMX Wall Docking Station MVP-WDSデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。