MIRA CLEAN ® 2000 GAS GRIDDLE INST ALLA TION MANU AL USER OPERA TION and MAINTEN ANCE SER VICE INSTR UCIONS “Serving Those Who Serve The Very Best” ® READ AND SA VE THIS MANUAL FOR FUTURE REFERENCE Record the Model No. and Serial No. of this Miraclean ® Griddle in the space provided below .
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. W A RNIN G Improper installation can c ause damage, injury or death.
INTRODUCTION Instructions in this manual should be read thoroughly before attempting to operate this Miraclean ® Griddle. All installation and service on Keating equipment must be performed by qualified, certified, licensed and/or authorized installation or service personnel.
GAS CONNECTIONS AND PIPE SIZE The Miraclean ® Griddle requires a standard gas pipe size of 3/4 inch (19mm) I.D. connection. The size of the gas supply pipe is very important if the pipe is too small you will have low gas pressure at the Miraclean ® Griddle manifold.
ASSEMBL Y INSTRUCTIONS FOR GRIDDLE ST AND ON CASTERS (THERE IS NO TOP ON THIS ST AND) PLACING MIRACLEAN ® GRIDDLE IN OPERA TION (When all previous instructions have been completed).
4 LIGHTING INSTRUCTIONS MIRACLEAN ® GRIDDLE (See lighting instructions plate attached to front of MIRACLEAN ® Griddle). Make sure that the main gas valve on the gas supply line to the Miraclean ® Griddle is in the “ON” position. 1. T urn gas valve knob to "pilot" position.
The Miraclean ® Griddle can be kept in perfect condition by using a razor blade griddle scraper to remove the film that is deposited from the products that have been previously cooked. Eggs, being cooked at a lower temperature, require substantially no scraping; but meat and meat products cooked at a higher temperature, do require scraping.
CLEANING THE MIRACLEAN® GRIDDLE The surface of the MIRACLEAN ® Griddle is very durable and with proper care, following the procedures below , will last many years. A sample of Keating Klenzer , Keating palmetto brush and a 4" scraper are included with each new griddle.
PREVENTIVE MAINTENANCE Preventive maintenance should be done in daily , weekly , monthly and yearly intervals as necessary . Following preventive maintenance procedures will help keep your MIRACLEAN ® Griddle working efficiently . Proper care and servicing will lead to years of quality performance.
8 Figure 6-3 Natural and Propane Gas Heating Systems ITEM DESCRIPTION P ART NUMBER 1 SP ARK IGNITION ASSEMBL Y SEE Item 4, Figure 6-2 2 THERMOPILE 022770 3 PILOT TUBE (1/4”) 007998 4 PILOT ASSEMBL Y.
9 SER VICE DIAGNOSIS The following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends that you use a qualified & licensed service company . (Equipment still under warranty requires it.) NOTE: T o correctly and quickly diagnose the system, the chart below should be followed in sequential order .
SER VICE Servicing should only be performed by qualified & licensed service companies. G A S VA LV E REGULA TOR ADJUSTMENT Recommended gas pressure at manifold (4.0" W .C. Natural gas 10.0" W .C. Propane gas) Adjustment of the gas valve pressure regulator is not normally necessary since it has been preset at the factory .
MILLIVOL T CHECK (FOR QUALIFIED SERVICE TECHNICIANS ONL Y ) The millivolt valve is a thermopile self-powered combination gas control. Before checking the millivolt system, the following operations should be performed and observations made: 1. A genuine Keating millivolt thermostat should be used for millivolt operation.
B. THERMOPILE OUTPUT CHECK (“B” Reading. Thermost at contacts OPEN - Main burner OFF .) 1. Thermopile system - 500 millivolt s minimum. If the minimum millivolt reading is not obtainable, readjust thermopile for maximum millivolt output. If millivolt reading is still below minimum specified, replace thermopile.
13 GAS GRIDDLE WIRING DIAGRAM CONTROL PANEL THERMOSTAT ON/OFF SWITCH.
L IMITED W ARRANTY Keating Of Chicago, Inc. ("K eating”) warrants to the original purchaser . ("Customer"), all new K eating Fryers, Filter Systems, Griddles, Keep Krisp®, Custom P a.
15 SER VICE INFORMA TION If you hav e a service related question call 1-800-KEA TING. Please state the nature of the call; it will ensure speaking with the appropriate person. Hav e your serial and model number av ailable when ordering parts. KEA TING OF CHICA GO, INC.
デバイスKeating Of Chicago MIRACLEAN Miraclean 2000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Keating Of Chicago MIRACLEAN Miraclean 2000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはKeating Of Chicago MIRACLEAN Miraclean 2000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Keating Of Chicago MIRACLEAN Miraclean 2000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Keating Of Chicago MIRACLEAN Miraclean 2000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Keating Of Chicago MIRACLEAN Miraclean 2000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はKeating Of Chicago MIRACLEAN Miraclean 2000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Keating Of Chicago MIRACLEAN Miraclean 2000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちKeating Of Chicago MIRACLEAN Miraclean 2000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。