Keiserメーカー1031の使用説明書/サービス説明書
ページ先へ移動 of 14
Solenoid Valve Replacement for 1030/1031 Compressor INTRODUCTION KEISER CORPORATION has always taken pride in designing and engineering the highest quality equipment on the market. This means that you will receive years of low maintenance and minimal repairs from every one of our machines.
10-5508 Rev A Service Department (800) 888-7009 2 Solenoid Valve Replacement for 1030/1031 Compressor * WARNING: Unplug compressor before beginning. Before replacing valve, draw all of the air out of the compressor by pressing both the + and – buttons on the exercise equipment.
10-5508 Rev A Service Department (800) 888-7009 3 Step Two: Remove hoses After the screws have been removed, take the ½ inch open-ended wrench, and loosen the nut that connects the hose to the valve by turning it counter-clockwise, and remove the hose.
10-5508 Rev A Service Department (800) 888-7009 4 Next, remove the lid to the computer control system box by unscrewing the screw on either side. remove two screws on lid Then remove the rubber grommet by using the needle nose pliers to carefully pop it out of the hole.
10-5508 Rev A Service Department (800) 888-7009 5 1030 Circuit Board Diagrams Rev A, B, C Rev D - Current.
10-5508 Rev A Service Department (800) 888-7009 6 push on board, pull on wire Pull each of the four wires back out the hole one by one. Save the rubber grommet.
10-5508 Rev A Service Department (800) 888-7009 7 Step One: Adjust and mount new valve First, make sure that the valve is open. Try to turn the pet-cock on the valve counter- clockwise. If you cannot turn it further counter-clockwise, it is open. open valve counter-clockwise The new valve allows you to rotate its housing for easy mounting.
10-5508 Rev A Service Department (800) 888-7009 8 Next, remove the compression nut that connects the hose to the valve. Replace it with the original compression nut, attach the hose, and tighten the compression nut finger tight. Take the ½ inch wrench and rotate the nut ½ to ¾ turn.
10-5508 Rev A Service Department (800) 888-7009 9 Left side valve Right side valve Repeat the process under Step One to mount the second valve. Step Two: Install single to double adapter and electrical wires Take all four electrical wires and insert them, one by one, through the rubber grommet, and then through the hole.
10-5508 Rev A Service Department (800) 888-7009 10 Step Two: Install single to double adapter and electrical wires Take all four electrical wires and insert them, one by one, through the rubber grommet, and then through the hole. Pull all of the slack into the computer system control box.
10-5508 Rev A Service Department (800) 888-7009 11 Take the single to double adapter and turn it so that the two top prongs are pointing to the left hand side of the box. The bent portion with these two prongs should be over the fuse. Replace the connector with the single to double adapter in L1.
10-5508 Rev A Service Department (800) 888-7009 12 Step Three: Secure and tie wires and replace lid Make sure that all of the slack is inside the computer control system box. Use a zip tie to bind the wires and hoses on the outside of the box. Use the wire cutters to cut off the excess.
10-5508 Rev A Service Department (800) 888-7009 13 feel for air flow After the flow of air has stopped, wait thirty seconds. Slowly lower the air in the compressor to approximately 95 PSI and the compressor should start. Open the valve by turning the handle counter-clockwise to allow the air to reach the equipment.
10-5508 Rev A Service Department (800) 888-7009 14 2470 S. Cherry Ave. Fresno, CA 93706 1(800) 888-7009 Fax: (559 )256-8100 e-mail: info@keiser.com www.
デバイスKeiser 1031の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Keiser 1031をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはKeiser 1031の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Keiser 1031の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Keiser 1031で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Keiser 1031を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はKeiser 1031の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Keiser 1031に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちKeiser 1031デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。