1 SA VE THIS MANUAL FOR FUTURE REFERENCE. Owner ’ s Manual FOR POT ABLE W A TER HEA TING ONL Y . NOT SUIT ABLE FOR SP ACE HEA TING . MODEL NO. 153.326162 30 Gallon Short 153.326163 30 Gallon Short 153.326264 38 Gallon Short 153.326265 38 Gallon Short POWER MISER™ 6 ELECTRIC W A TER HEA TER Sears, Roebuck and Co.
2 SAFE INST ALLA TION, USE AND SER VICE Y our safety and the safety of others is extremely important in the inst allation, use and servicing of this water heater . Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard.
3 GENERAL SAFETY.
4 T ABLE OF CONTENTS SAFE INST ALLA TION, USE AND SERVICE ............................................................................................. ......................................... 2 GENERAL SAFETY ........................................
5 Thank Y ou for purchasing a Sears water heater . Properly installed and maintained, it should give you years of trouble free service. It is strongly suggested that this new water heater be professionally installed, cont act the local Sears Service Center or any Sears store.
6 MA TERIALS AND BASIC TOOLS NEEDED Basic T ools Y ou may or may not need all of these tools, depending on your type of installation. These tools can be purchased at your local Sears store.
7 Removing the Old W ater Heater FIGURE 1. 1. T urn “OFF” electrical supply to the water heater . FIGURE 2. 2. T urn “OFF” the water supply to the water heater at the water shut-off valve or water meter . FIGURE 3. 3. Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors.
8 from some plumbing wholesalers and retailers, and detect and react to leakage in various ways: • Sensors mounted in the drain p an that trigger an alarm or turn off the incoming water to the water heater when leakage is detected.
9 Before making the conversion to 5500 watts, check the (1) power supply . . . must be 240 volts, (2) wiring . . . 10 gauge AWG @ T ype TW , 60°C or equivalent, and (3) Circuit breakers or fusing . . .capable of 30 amp loading. Also, the inst allation must conform with this manual, local codes and electric utility rules.
10 NOTE: T o protect against untimely corrosion of hot and cold water fittings, it is strongly recommended that di- electric unions or couplings be installed on this water heater when connected to copper pipe. 1. Look at the top cover of the water heater .
11 is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances. Excessive length, over 30 feet (9.14 m), or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve.
12 Filling the W ater Heater Never use this water heater unless it is completely full of water . T o prevent damage to the tank and heating element, the t ank must be filled with water . W ater must flow from the hot water faucet before turning “ON” power .
13 Necessary element conversion parts are located in a small bag contained within the electrical junction box on top of the water heater . FIGURE 12. 1. Before beginning the conversion turn “OFF” electric power supply to the water heater . FIGURE 13.
14 8. Tighten terminals 2 and 3 to ensure proper electrical connection. Failure to tighten terminal screws can cause a fire which can result in DEA TH, SERIOUS BODIL Y INJURY , OR PROPERTY DAMAGE. 9. Replace terminal cover on thermostat making sure that the locking tabs on the terminal cover are in place.
15 If you are not familiar with electric codes and practices, or if you have any doubt, even the slightest doubt, in your ability to connect the wiring to this water heater , obtain the service of a competent electrician. Cont act your Sears salesperson to arrange for a professional electrician.
16 Wiring Diagrams ST ANDARD WIRING FOR 2 WIRE LEAD W A TER HEA TERS NON-SIMUL T ANEOUS OPERA TION 240 VOL T DOUBLE ELEMENT FIGURE 24. FIGURE 25. WIRING FOR 3 WIRE LEAD W A TER HEA TERS NON-SIMUL T ANEOUS OPERA TION 240 VOL T DOUBLE ELEMENT *NOTE: Some lower Hi-T emp Limit Switches may have 4 terminals.
17 The lower thermostat is factory set at a position which approximates 120°F (49°C), and is adjustable if a different water temperature is desired. Read all warnings in this manual and on the water heating before proceeding.
18 NOTE: It is not necessary to adjust the upper thermost at. However , if it is adjusted above the factory set point of 120°F (49°C), it is recommended that it not be set higher than the lower thermostat setting. The upper and lower thermostats are adjust able if a different water temperature is desired.
19 The water heater should be drained if being shut down during freezing temperatures. Also, periodic draining and cleaning of sediment from the tank may be necessary . 1. Before beginning turn “OFF” the electric power supply to the water heater .
20 1. Before beginning turn “OFF” the electric power supply to the water heater . FIGURE 30. 2. Turn of f the water supply to the water heater at the water Shut-off valve or water meter . FIGURE 31. 3. Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors.
21 8. Clean the area around the element opening. Remove any sediment from or around the element opening, inside the tank. 9. If you are cleaning the element you have removed, do so by scraping or soaking in vinegar or a de-liming solution.
22 18. Replace access panel. 19. T urn “ON” electric power to water heater . FIGURE 41. Drain V alve W asher Replacement. NOTE: For replacement, use a 17/32" x 13/64" x 1/8" thick washer available at your nearest hardware store. For ordering a replacement washer , refer to the “Repair Part s List” section.
23 S tart Up Conditions THERMAL EXP ANSION W ater supply systems may , because of such events as high line pressure, frequent cut-offs, the ef fects of water hammer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc.
24 D. An excess of active hydrogen in the tank. This is caused by corrosion protective action of the anode. Smelly water may be eliminated or reduced by chlorinating the water heater tank and all hot water lines. Cont act the local Sears Service Center concerning this Chlorination T reatment.
25 NOT ENOUGH OR NO HOT W A TER 1. In a new inst allation, the water heater may not be properly connected. Make sure the cold water supply valve is open.
26 FIGURE 46. Leakage Checkpoint s Read this manual first. Then before checking the water heater make sure the electric supply has been turned “OFF”, and never turn the electric supply “on” before the tank is completely full of water . Use this guide to check a “Leaking” water heater .
27 Now that you have purchased this water heater , should a need ever exist for repair pa rts or service, simply contact any Sears Service Center or call 1-800-4-MY -HOME (1-800-469-4663). Be sure to provide all pertinent facts when you call or visit.
28 6 - YEAR LIMITED W ARRANTY ON W A TER HEA TER For six years from the date of purchase, if this water heater is installed and operated in a single-family home in accordance with the owner ’ s manual instructions and all local applicable plumbing codes, Sears will: 1.
デバイスKenmore 153.326264の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Kenmore 153.326264をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはKenmore 153.326264の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Kenmore 153.326264の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Kenmore 153.326264で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Kenmore 153.326264を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はKenmore 153.326264の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Kenmore 153.326264に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちKenmore 153.326264デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。