I CONSUMER SERVICES TECHNICAL EDUCA TION GROUP PRESENTS KD-10 JOB AID Part No. 4322430 1998 DISHWASHERS Servicing and Troubleshooting MODELS DU800DWG DU801DWG DU805DWG DU810DWG DP840DWG DU840DWG DU850.
II INTRODUCTION This Job Aid, “1998 DISHW ASHERS, Servicing and T roubleshooting ,” (Part No. 4322430) provides specific information for the installation, service and repair of 1998 Whirlpool Dishwashers.
III TABLE OF CONTENTS INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . II T ABLE OF CONTENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . III SAFETY . . . . . . . . . . . . . .
IV -- NOTES --.
1 Section One DURAWASH MODELS WITH SOIL SETTLER AND TELESCOPING TOWER THEOR Y OF OPERA TION Console Configuration DU800DWG, DU801DWG, DU805 DU810DWG DU840DWG, DP840DWG DU850DWG DU890DWG.
2 Special Feature Soil Settler This model is equipped with a soil settler system. The inlet to the soil settler funnel is located to the right and just behind the lower spray arm assembly .
3 COMPONENT ACCESS Component Location ! W ARNING ELECTRICAL SHOCK HAZARD Disconnect electric supply from the dishwasher before servicing. Replace all panels before operating.
4 Removing the Spray Arm Assembly 1. Disconnect the dishwasher from the house- hold electrical system. 2. Open the dishwasher door and remove the lower rack. 3. Use an adjustable slip-nut wrench and loosen the pump outlet nut. (Fig. 1-4) 4. Lift the spray arm assembly out of the pump fitting.
5 4. Disconnect the drain hose from the drain valve by loosening the Hex-head screw on the hose clamp. (Fig. 1-7) 5. Disconnect the pump inlet hose from the pump and motor assembly . (Fig. 1-7) 6. Remove the pump and motor assembly from the bottom of the dishwasher .
6 Removing the Soil Settler Assembly 1. Disconnect the dishwasher from the household electrical system and lay the unit on its back. 2. Remove the four (4) Hex-head screws securing the soil settler assembly to the tub. 3. Disconnect the two (2) hoses from the soil settler collector .
7 Removing the W ater Inlet V alve 1. Turn of f the water supply to the dishwasher . 2. Turn the timer knob clockwise to the NORMAL W ASH position to energize the water inlet valve and relieve water pressure in the line. 3. Turn the electrical supply to the dishwasher of f and remove the toe panel and access panel.
8 1. Disconnect the dishwasher from the electrical supply and remove the toe panel and access panel from the bottom of the dishwasher . 2. Disconnect the end of the door springs from the door spring tension adjustment holes in the frame runner .
9 1. Disconnect the dishwasher from the electrical supply and remove the toe panel and access panel from the bottom of the dishwasher and the inner door panel. 2. Disconnect the harness wires from the spade connectors on the switch assembly . (Fig. 1-24) 3 .
10 Dishwasher Dispenser Disassembly 1. Remove the drawbar spring. (Fig. 1-26) 2. Align the lower drawbar holes with the locking tabs and remove the upper and lower drawbars. As you do, note the locating tabs behind them and how they align with their respective locating holes.
11 Fig. 1-28 Fig. 1-29 Fig. 1-30 Fig. 1-31.
12 Dishwasher Dispenser Assembly 1. Assembly the upper slide, slide spring and lower slide to the detergent door actuator . (Fig. 1-32) 2. Pass the detergent door latch lever through the panel making sure to turn the hook of the latch toward the detergent door .
13 SOLUTIONS T O COMMON PROBLEMS DIAGNOSING PROBLEM COMPONENTS PRECAUTIONS TO BE OBSERVED WHILE DIAGNOSING PROBLEM COMPONENTS Disconnect electric power from the dishwasher . V oltage checks should be made by inserting meter probes beside the wires in the connector blocks with the electric power source on and the connector block plugged in.
14 COMPONENT SCHEMA TIC TESTING PROCEDURE RESUL TS Timer Motor Timer Dispenser Mechanism 1. Disconnect the Wiring harness connector from the timer assembly . 2. Set VOM meter on the Rx1 scale. 3. Measure resistance between timer motor terminals. 1. Disconnect the wiring harness connector from the timer assembly .
15 PRECAUTIONS T O BE OBSER VED WHILE TROUBLESHOOTING AND DIAGNOSING PROBLEMS Always check wiring harness and connectors before initiating any test procedures. Disconnect electric power from the dishwasher before touching the printed circuit boards or re-seating wire connectors.
16 TECHNICAL INFORMA TION Wiring Diagram Models DU800DWG, DU801DWG, DU805DWG SCHEMA TIC SHOWN WITH DOOR SWITCHES CLOSED, ALL CONT ACTS OPEN.
17 Cycle T iming Chart.
18 Wiring Diagram Model DU810DWG SCHEMA TIC SHOWN WITH DOOR SWITCHES CLOSED, ALL CONT ACTS OPEN.
19 Cycle T iming Chart.
20 Wiring Diagram Models DU840DWG, DP840DWG SCHEMA TIC SHOWN WITH DOOR SWITCHES CLOSED, ALL CONT ACTS OPEN.
21 Cycle T iming Chart.
22 Wiring Diagram Model DU850DWG SCHEMA TIC SHOWN WITH DOOR SWITCHES CLOSED, ALL CONT ACTS OPEN.
23 Cycle T iming Chart.
24 Wiring Diagram Model DU890DWG SCHEMA TIC SHOWN WITH DOOR SWITCHES CLOSED, ALL CONT ACTS OPEN.
25 Cycle T iming Chart.
26 --NOTES --.
27 Section T wo POWER CLEAN FILTER MODELS WITH TOWER WATER FEED Models: DU910PFG, DP920PFG, DU920PFG THEOR Y OF OPERA TION Console Configuration Model DU910PFG Models DP920PFG, DU920PFG 1. Once the tub has filled with hot water the motor begins to rotate forcing the water up through the pump chamber and out through the spray arms.
28 COMPONENT ACCESS TIMER LA TCH ASSEMBL Y FILL VA L V E MOT OR RELA Y FLOA T SWITCH OPERA TING THERMOST A T (Attached to bottom of pump housing) HI LIMIT THERMOST A T PUMP AND MOT OR ASSEMBL Y HEA TE.
29 Removing the Heater Element From beneath the cabinet: 1. Remove the front access panel. (See Removing the Outer Door Panel) 2. Pull the spade connectors off the heater element terminals. 3. Unscrew the two (2) nuts securing the heater element to the bottom of the tub.
30 2. Disconnect the wiring harness from the motor harness plug. 3. Rubber clamps secure the pump and motor assembly to the tub. Rotate these inward 90°. (Fig. 2-7) 4. Remove the drain hose and clamp from the check valve and unscrew the check valve from the pump.
31 ACCESSING COMPONENT INSIDE THE DISHW ASHER DOOR Removing Access and Outer Door Panels 1. Loosen but do not remove the two (2) toe panel screws below the access panel. Re- move and set aside the two (2) screws above the access panel. (Fig. 2-11) 2. Remove the access panel assembly by slid- ing it upward to clear the loosened screws.
32 Replacing the Spring Loaded Locking T ab The inner door panel is held in place by a spring loaded locking tab located on the door frame rail, just below the console. (Fig. 2-14) T o remove this assembly , remove the spring and slide the locking tab back until the locating tab is in the key hole.
33 TROUBLESHOOTING GUIDE Model DU910PFG PRECAUTIONS T O BE OBSER VED WHILE TROUBLESHOOTING AND DIAGNOSING PROBLEMS Always check wiring harness and connectors before initiating any test procedures. Disconnect electric power from the dishwasher before touching the printed circuit boards or re-seating wire connectors.
34 TECHNICAL INFORMA TION Model DU910PFG Wiring Diagram SCHEMA TIC SHOWN WITH DOOR SWITCHES CLOSED, ALL CONT ACTS OPEN.
35 Strip Circuits HEA T DR Y (Steps 30 - 44) FILL (Steps 1, 9, 14, 23, 48) W ASH (Steps 2 - 7, 10 - 12, 15 - 20, 24 - 28, 49) DRAIN (Steps 8, 13, 21 - 22, 29, 50) W A TER HEA TING (Steps 6 - 7, 18 - 1.
36 Cycle T iming Charts.
37 PROBLEM POSSIBLE CAUSES CORRECTION/TEST Dishwasher does not run or stops during a cycle Dishwasher will not fill Dishwasher will not drain Dishwasher will not dry dishes 1. Door is not latching properly . 2. Child lock is "ON". 3. W ash Cycle not set properly .
38 TECHNICAL INFORMA TION Models DP920PFG & DU920PFG WIRING DIAGRAM CONNECT OR PIN OUT Pin No. DESCRIPTION P1 P2-1 P2-2 P2-3 P2-4 P2-5 P3 P4 P5 P6 P7 P8 P10 Ribbon Cable to User Interface Pressure.
39 STRIP CIRCUITS.
40 STRIP CIRCUITS CYCLE TIMING CHART.
41 Note 1: Pre-Wash Sense Interval Pressure switch contact closure at any time during this interval causes the cycle to jump to interval 37. Immediately. For the normal cycle, the heater is “off” during this interval. For the heavy and pots-n-pans cycles the heater is “on” during this interval.
42 1. The diagnostics test cycle starts at interval 11 and concludes at interval 2. To initiate the diagnostics test cycle, press the following sequence of keys within 10 seconds: High Temp Wash, Air .
43 Section Three POWER CLEAN FILTER MODELS WITH INTERNAL WATER FEED Models: GU940SCG, GU960SCG, GU980SCG THEOR Y OF OPERA TION Console Configurations Model GU940SCG Model GU960SCG Model GU980SCG 1. Once the tub has filled with hot water the motor begins to rotate forcing the water up through the pump chamber and out through the spray arms.
44 COMPONENT ACCESS Servicing the V ertical W ater T ube The vertical water tube in these models delivers water to the spray arm mounted underneath the upper dish rack and a smaller spray arm mounted at the top of the dishwasher tub.
45 Servicing The Dishwasher Dispenser Assembly Models DU920SFG, DP920SFG, GU940SFG, GU960SFG and GU980SFG utilize a modified draw bar to accommodate two wax motors (Fig. 3-9) to activate the detergent and wetting agent dispensers. The remainder of the dispenser as- sembly is serviced in the same manner as all other models.
46 Fig. 3-10 Fig. 3-11 Dishwasher Dispenser Disassembly 1. Remove the drawbar spring. (Fig. 3-10) 2. Grasp the lower edge of the drawbar and pull it away from the panel stop. Slide the drawbar down until the drawbar holes align with the locking tabs, then remove the drawbar .
47 Fig. 3-12 Fig. 3-13 Fig. 3-14.
48 Dishwasher Dispenser Assembly 1. Assembly the slide and slide spring to the detergent door actuator . (Fig. 3-15) 2. Pass the detergent door latch lever through the panel, making sure to turn the hook of the latch toward the detergent door . Snap the detergent door latch snap onto the door latch lever .
49 1. The diagnostics test cycle starts at interval 11 and concludes at interval 2. To initiate the diagnostics test cycle, press the following sequence of keys within 10 seconds: High Temp Wash, Air .
50 PROBLEM POSSIBLE CAUSES CORRECTION/TEST Dishwasher does not run or stops during a cycle Dishwasher will not fill Dishwasher will not drain Dishwasher will not dry dishes 1. Door is not latching properly . 2. Child lock is "ON". 3. W ash Cycle not set properly .
51 WIRING DIAGRAM TECHNICAL INFORMA TION Model DU940SCG, DU960SCG, DU980SCG CONNECT OR PIN OUT Pin No. DESCRIPTION P1 P2-1 P2-2 P2-3 P2-4 P2-5 P3 P4 P5 P6 P7 P8 P10 Ribbon Cable to User Interface Pres.
52 STRIP CIRCUITS.
53 STRIP CIRCUITS CYCLE TIMING CHART.
54 Note 1: Pre-Wash Sense Interval Pressure switch contact closure at any time during this interval causes the cycle to jump to interval 37. Immediately. For the normal cycle, the heater is “off” during this interval. For the heavy and pots-n-pans cycles the heater is “on” during this interval.
55 Removing Access and Door Panels 1. Loosen but do not remove the two (2) toe panel screws below the access panel. Re- move and set aside the two (2) screws above the access panel. (Fig. 4-1) 2. Remove the access panel assembly by slid- ing it upward to clear the loosened screws.
56 4. Pull the bottom of the outer door panel out- ward and slide it down approximately ¼” to ½”. The panel will then be free for removal. (Fig. 4-1, inset) Set the door panel aside; it will be replaced with a new custom panel. 5. Remove the existing door insulation and dis- card.
57 6. Place the access panel front side down. In- stall the metal access panel extension into the slot it the access panel by pushing down firmly until the extension snaps into place. (Fig. 4-7) 7. Remove the adhesive backing from the ac- cess panel insulation and press the insula- tion firmly into place.
58 Installing Heavy Duty Door Springs Standard door springs may need to be replaced by heavy duty springs designed to compensate for the increased weight of the door resulting from the installation of custom panels. Perform the following tests to determine whether the heavy duty springs need to be installed.
59 INST ALLING THE FLOOR MOUNTING KIT KIT CONTENTS (P/N 4378968): 2 P/N 9743463 Brackets (Fig. 4-12) 1 P/N 4378974 Instruction Sheet INST ALLA TION INSTRUCTIONS 1. Loosen the two (2) screws below the access panel and remove the two (2) screws above the access panel.
60 -- NOTES --.
V.
VI.
デバイスKenmore DU890DWGの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Kenmore DU890DWGをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはKenmore DU890DWGの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Kenmore DU890DWGの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Kenmore DU890DWGで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Kenmore DU890DWGを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はKenmore DU890DWGの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Kenmore DU890DWGに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちKenmore DU890DWGデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。