Owner's Manual POWER MISER TM 12 GAS WATER HEATER FOR POTABLE WATER HEATING ONLY. NOT SUITABLE FOR SPACE HEATING. NOT FOR USE IN MOBILE HOMES. MODEL NO.
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard.
Read and understand instruction manual and safety messages before installing, operating or servicing this water heater Failure to follow instructions and safety messages could result in death or serious injury. Instruction manual must remain with water heater.
SAFE INSTALLATION, USE AND SERVICE ................................................................................................. 2 SAFETY PRECAUTIONS .................................................................................................
Thank You for purchasing a Kenmore water heater. Properly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears call 1-800-4-MY-HOME ®. They will arrange for prompt, quality installation by Sears authorized contractors.
Materials Needed To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these material, depending on your type of installation. WATER HEATER INSTALLATION KIT WITH FLEXIBLE CONNECTORS FOR 3/4" (19.
GET TO KNOW YOUR WATER HEATER - GAS MODELS A Vent Pipe B Draft Hood C Anode D Hot Water Outlet E Outlet F Flexible Water Connections G Gas Supply H Manual Gas Shut-off Valve I Ground Joint Union J Dri.
Removing the Old Water Heater ® ® ® FIGURE2, Q Tum "OFF" the gas supply to the water heater. If the main gas line shutoff valve serving all gas appliances is used, also shut "OFF" the gas at each appliance. Leave all gas appliances shut "OFF" until the water heater installation is completed, see Figures 2 and 3.
Facts to Consider About the Location Carefully choose an indoor location for the new water heater, because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance.
Breathing Hazard - Carbon Monoxide Gas Install water heater in accordance with the instruction manual and NFPA 54. To avoid injury, combustion and ventilation air must be taken from outdoors. Do not place chemical vapor emitting products near water heater.
Combustion Air and Ventilation for • Appliances Located in Confined Spaces CONFINED SPACE is a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m 3 per kW) of the aggregate input rating of all appliances installed in that space• A.
Special Conditions Created by Mechanical Exhausting or Fireplaces: operation of exhaust fans, ventilation systems, clothes dryers or fireplaces may create conditions requiring special attention to avoid unsatisfactory operation ofinstalled gas utilization equipment.
Look at the top of the water heater. The cold water inlet is marked "COLD". Put two or three turns of teflon tape around the threaded endof the threaded-to-sweat coupling and around both ends of the 3/4" NPT threaded nipple. Using flexible connectors, connect the cold water pipe tothe cold water inlet ofthe water heater.
HOT WATER OUTLET COLD WATER VALVE HOT COLD TEMPERATURE=PRESSURE RELIEF VALVE (OPTIONAL TOP T & P RELIEF DRAFT HOOD VALVE NOT SHOWN) DISHCARGE PIPE (DO NOT CAP OR PLUG) DRAIN VALVE _ FLOOR DRAIN FIGURE16, Water Damage Hazard • Temperature-pressure relief valve discharge pipe must terminate at adequate drain.
and mechanically actuated vent dampers). Before installation ofany vent damper, consult your local Sears Service Center or the local gas supplier for further information. Breathing Hazard - Carbon Monoxide Gas • Vent dampers must be certified in accordance with ANSI Z21.
Be sure vent pipe is properly connected to prevent escape of dangerous flue gases which could cause deadly asphyxiation. Chemical vapor corrosion of the flueand vent system may occur if air for combustion contains certain chemical vapors.
Sediment Traps Contaminants in gas lines can cause fire or explosion. • Clean all gas piping before installation. • Install drip leg in accordance , _ , with NFPA 54.
FOR YOUR SAFETY READ BEFORE LIGHTING I WARNING= ,f you de not fo"ow these =nstruct ons exact=y a f re or explosion may result causing property damage, personal injury or loss of life. BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES.
Temperature Regulation Due to the nature of the typical gas water heater, the water temperature in certain situations may vary up to 3OF ° (16.7 C °) higher or lower at the point of use such as, bathtubs, showers, sink, etc. Any water heater's intended purpose is to heat water.
Tank (Sediment) Cleaning Burner Inspection Sediment build-up on the tank bottom may create varying amount of noise, and if left in the tank will cause permanent tank failure. In some water areas, you may not be able to drain all sediment deposits by simply draining the tank.
Housekeeping Vacuum around base of water heater for dust, dirt, and lint on a regular basis. Fire and Explosion Hazard Temperature-Pressure Relief Valve Operation The temperature-pressure relief valve must be manually operated at least once a year. • Do not obstruct combustion air openings at the bosom of the water heater.
2. CLOSE the cold water inlet valve tothe water heater. 3. OPEN a nearby hot water faucet and leave open toallow for draining. 4. Connect a hose to the drain valve and terminate to an adequate drain. 5. OPEN the water heater drain valve toallow for tank draining.
Start Up Conditions Thermal Expansion Property Damage Hazard • Avoid water heater damage. • Install thermal expansion tank or device if necessary, • Contact qualified installer or service agency NOTE: Expansion tanks are pre-charged with a 40 psi air charge.
is not drawn toward the draft hood, shut off water heater and make necessary air supply changes to correct. Condens_ion Whenever the water heater is filled with cold water, some condensate will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensation.
Operational Conditions (Continued) Leakage Checkpoints FIGURE27. Read and understand instruction manual and safety messages before installing, operating or servicing this water heater. Failure to follow instructions and safety messages could result in death or serious injury Instruction Manual must remain with water heater.
These guidelines should be used by a qualified service agent, Call Sears Service at1-800-4-MY-HOME (1-800-469-4663) for assistance, Inform the associate that this is a "Flammable Vapor Ignition Resistant" Product, Improperly sealed, hot or cold supply connection, relief valve, drain valve, or thermostat threads.
POWER MISER TM 12 GAS WATER HEATER 153.331413 HA 153.331443 153.331514 HA 153.331543 40 Gallon High Altitude 40 Gallon 50 Gallon High Altitude 50 Gallon 1 BURNER ASSEMBLY Key No, 1 2 3 4 5 6 7 8 9 10 .
FULL ONE YEAR WARRANTY ON WATER HEATER For one year from the date of purchase, when your Sears Kenmore water heater is installed and operated in a single-family residence in accordance with the instructions in this manual, Sears will: 1 Repair defects in material or workmanship in this water heater, free of charge 2.
デバイスKenmore Power Miser 12 153.331413 HAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Kenmore Power Miser 12 153.331413 HAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはKenmore Power Miser 12 153.331413 HAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Kenmore Power Miser 12 153.331413 HAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Kenmore Power Miser 12 153.331413 HAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Kenmore Power Miser 12 153.331413 HAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はKenmore Power Miser 12 153.331413 HAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Kenmore Power Miser 12 153.331413 HAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちKenmore Power Miser 12 153.331413 HAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。