CMA5000 Multi-Layer T est Solution Order Guide Order Guide.
CMA5000 Multi-Layer T est Solution Order Guide Pa g e 2 o f 16 CMA5000 - Mainframe Order Guide The CMA5000 Mainframe is available with a Small (SBA), Medium (MBA) or Large (LBA) Bay Adapter and includ.
CMA5000 Multi-Layer T est Solution Order Guide Pa g e 3 o f 16 Optical Accessories 1 Option-501CD-RW CMA5000 CD/read/write module upgrade O ption-502FLOPPY CMA5000 floppy drive module Option-503DESKTO.
LEGEND Go Available power option Stop Not supported with this power configuration N/A Does not fit in SBA and requir es all slots of MBA Note When using multiple modules, you must review all module technologies to confirm operability .
CMA5000 Multi-Layer T est Solution Order Guide Pa g e 5 o f 16 LEGEND Go Available power option Stop Not supported with this power configuration N /A Does not fit in SBA and requir es all slots of MBA Note When using multiple modules, you must review all module technologies to confirm operability .
CMA5000 Multi-Layer T est Solution Order Guide Pa g e 6 o f 16 CMA5000 - OTDR Module Order Guide The CMA5200 OTDR’ s are Single Bay modules that include one OTDR/Source Universal Adapter (UC-130-XX) at no charge. For units with a Power Meter option, a Meter Connector Adapter (LP-XX) is also included at no charge.
CMA5000 Multi-Layer T est Solution Order Guide Pa g e 7 o f 16 5236-110-OTDR-AFC Singlemode, 40/40/40 dB dynamic range, tri-wavelength 1310/1550/1625 nm, Power Meter and Light Source with FC/APC connector 5266-001-OTDR-UFC Multimode 24/26 dB dynamic range, dual-wavelength 850/1300 nm, 62.
CMA5000 Multi-Layer T est Solution Order Guide Pa g e 8 o f 16 CMA5000 - SDH/SONET XT A Module Order Guide The CMA5600 XT A module is a test module for T -Carriers/PDH and SONET/SDH technologies up to 10 Gbps (depends on the module). It is a double (2-bay) module and can be used in either an SBA, MBA or LBA.
CMA5000 Multi-Layer T est Solution Order Guide Pa g e 9 o f 16 CMA5000 OSA Or der Guide This module requir es the following open slots: SBA MBA LBA CMA5000 - OSA (Optical Spectrum Analyzer) Module Order Guide The CMA 5500 OSA modules cover the 1250 - 1650 nm spectral range.
CMA5000 Multi-Layer T est Solution Order Guide Pa g e 1 0 o f 16 CMA5000 Polarization Mode Dispersion Or der Guide PMD module The PMD application is a double deep module which operates in a CMA5000 MBA or LBA. PMD range is up to 160ps for a birefringent fiber and 80ps for telecom fiber .
CMA5000 Multi-Layer T est Solution Order Guide Pa g e 1 1 o f 16 This module requir es the following open slots: SBA MBA LBA 1550 nm C-Band source This is the ultra-broadband wavelength source offering 1550 nm operation and a minimum PMD measurement of 0.
CMA5000 Multi-Layer T est Solution Order Guide Pa g e 1 2 o f 16 CMA5000 Gigabit Ether net Or der Guide CMA5000 - Gigabit Ethernet Module Order Guide The Channel Statistics software option allows the user to quickly identify the r oot cause of network impairments, not just the symptoms.
CMA5000 Multi-Layer T est Solution Order Guide Pa g e 1 3 o f 16 CMA Ether net Reflector The 10/100/1000 Mbps Ethernet traffic reflector box is a small, standalone unit available in two versions.
CMA5000 Multi-Layer T est Solution Order Guide Pa g e 1 4 o f 16 CMA5000 10 Gigabit Ether net Or der Guide CMA5000 - 10 Gigabit Ethernet Module Order Guide The CMA5800 10 Gigabit Ethernet module is a double wide module with modular optics that can be used in an SBA, MBA or LBA.
CMA5000 Multi-Layer T est Solution Order Guide Pa g e 1 5 o f 16 CMA5000 OTDR/Chr omatic Dispersion Order Guide The CMA5302 OTDR based Chromatic Dispersion unit is a single bay module that can be used in either an SBA, MBA or LBA. It features time of flight CD measur ements as well as traditional tri-wavelength OTDR testing.
ISO 9001:2000 certified. ICMA5000-OGRevB-2-0606-A4. ©2006 Anritsu. All Rights Reserved. Specifications subject to change without notice. E&EO. Anritsu Corporation 5 -1-1 Onna, Atsugi-shi, Kanagawa, 243-8555 Japan P hone: +81-46-223-1111 Fax: +81-46-296-1264 • U .
デバイスAnritsu CMA5000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Anritsu CMA5000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAnritsu CMA5000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Anritsu CMA5000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Anritsu CMA5000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Anritsu CMA5000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAnritsu CMA5000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Anritsu CMA5000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAnritsu CMA5000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。