Kraftware CorporationメーカーDS-16M2の使用説明書/サービス説明書
ページ先へ移動 of 22
1 This document explains the power , cooling, w eight, and rack placemen t requirements for the EMC departmental switch es listed below . It also describes the kits available for m ounting them in EMC and non- EMC racks and incl udes insta llation instruction s as well.
2 EMC Depar tmen tal Switches DS-16M 2 and DS-32 M2 Installatio n Guide Device P ow er , Cooling, and W eight Inf ormation De vice P o w er , Co oling, and W eight Information De vice Di mensions De v.
EMC Depar tm ental Switches DS-16M2 and DS -32M2 Install ation Guide 3 Switch Mounting Kit (DS-16M or DS-32M) Switch Mounting Kit (DS-1 6M or DS-32M) The DS1 6- and DS32- CRKH kits cont ain the 16- or.
4 EMC Depar tmen tal Switches DS-16M 2 and DS-32 M2 Installatio n Guide Switch Mounting Kit (DS-16M or DS-32M) T oo ls Required f or Ins tallat ion Y ou will n eed to have the foll owing tool s available to com plete the installatio n of the rails an d switch(es).
EMC Depar tm ental Switches DS-16M2 and DS -32M2 Install ation Guide 5 Installing the DS-16M and DS-32M Rails Installing the DS-16M and DS-32M Rails This secti on describes the install ation procedures for the D S-16M an d DS-32M ra ils. The fig ures bel ow show a fro nt and r ear view of four sets of rails ins talled in a 39U rack.
6 EMC Depar tmen tal Switches DS-16M 2 and DS-32 M2 Installatio n Guide Installing the DS-16M and DS-32M Ra ils DS-16M Rails Installatio n There are two dif f er ent length rails: The short rails range between 20.5 inches to 27 inches. The long rails range fr o m 27 inches to 34 inches.
EMC Depar tm ental Switches DS-16M2 and DS -32M2 Install ation Guide 7 Installing the DS-16M and DS-32M Rails 1. Assemble the rails. The rails assembl y consis ts of an adjust able rai l, a C cha nnel, and two washers and kep nuts. See the figure below .
8 EMC Depar tmen tal Switches DS-16M 2 and DS-32 M2 Installatio n Guide Installing the DS-16M and DS-32M Ra ils 3. Adjust the length o f the rail to fit between the channels in the rack/cabinet. NOTE: The rail flanges go to the in side of the channels.
EMC Depar tm ental Switches DS-16M2 and DS -32M2 Install ation Guide 9 Installing the DS-16M and DS-32M Rails M5 x 16 mm flat head screw s (see the table on page 3 ). Leave the screws finger-tight, and tighten them after the switch is installed. See the figur e below .
10 EMC Depar tmen tal Switches DS-16M 2 and DS-32 M2 Installatio n Guide Installing the DS-16M and DS-32M Ra ils 7. If you are installing the switch in a 39U cabinet, position t he #10 washer and ball stud in the center hole, between the two M5 x 12 mm screws.
EMC Depar tm ental Switches DS-16M2 and DS -32M2 Install ation Guide 11 Installing the DS-16M and DS-32M Rails 9. Se cure t he rail t o a r ound-hol e r ear channel with 2 M5 x 12 mm pan-head scr ews .
12 EMC Depar tmen tal Switches DS-16M 2 and DS-32 M2 Installatio n Guide Installing the DS-16M and DS-32M Ra ils DS-32M Rails Installatio n There are two dif ferent length rails: the short rails range fr om 20.5 inches to 27 inches. The long rails range fro m 27 inches to 34 inches.
EMC Depar tm ental Switches DS-16M2 and DS -32M2 Install ation Guide 13 Installing the DS-16M and DS-32M Rails Select the appropriate length rails, and follo w the steps below to install th em. 1. Assemble the rails. The rails assembl y consis ts of an adjust able rai l, a C cha nnel, and two washers and nuts.
14 EMC Depar tmen tal Switches DS-16M 2 and DS-32 M2 Installatio n Guide Installing the DS-16M and DS-32M Ra ils 3. Adjust the length o f the rail to fit between the channels in the rack/cabinet. NOTE: The rail flanges go to the in side of the channels.
EMC Depar tm ental Switches DS-16M2 and DS -32M2 Install ation Guide 15 Installing the DS-16M and DS-32M Rails If you are installing the switch in a 40U cabinet , use the appr opriate screws to install the latch bracket (ins tead of the ball stud) to the outside edge of the channel a s you secure the rail.
16 EMC Depar tmen tal Switches DS-16M 2 and DS-32 M2 Installatio n Guide Installing the DS-16M and DS-32M Ra ils 8. Secure the rail to a round-hole rear channe l with two M 5 x 12 mm scre ws (see the .
EMC Depar tm ental Switches DS-16M2 and DS -32M2 Install ation Guide 17 Installing the DS-16M2 an d DS-32M2 Switches Installing the DS-16M2 and DS-32M2 Switc hes This section describes the pr ocedur es for installing the DS-16M2 an d DS-32M2 sw itches in a rack/cabin et, including attachin g the brackets on the switch.
18 EMC Depar tmen tal Switches DS-16M 2 and DS-32 M2 Installatio n Guide Installing the DS-16M2 an d DS-32M2 Switches CAUTION ! The kits incl ude two (2) sets of screws. T o avoid d amaging the screw holes, be sure to check the labe ling on the bag s and use the appropriate se t of screws for your chassis.
EMC Depar tm ental Switches DS-16M2 and DS -32M2 Install ation Guide 19 Installing the DS-16M2 an d DS-32M2 Switches 5. Push the switch further into the rack/cabinet un til the hole in th e front part of each bracket (the “L”-sh aped end) aligns w ith the hole on the fixed rail.
20 EMC Depar tmen tal Switches DS-16M 2 and DS-32 M2 Installatio n Guide Installing the DS-16M2 an d DS-32M2 Switches 8. Install the bez el by positioni ng and insta lling the b ezel stud receptacles on the back of the bezel over the ball studs (39U rack) or latch brackets (40U rack) on the rail ends.
EMC Depar tm ental Switches DS-16M2 and DS -32M2 Install ation Guide 21 Installing the DS-16M2 an d DS-32M2 Switches NOTE: There is a 3-inch space between the front of the switch and the back of the bezel. Thi s is enough room t o loop the co rd up with out pu shing th e bezel off.
22 EMC Depar tmen tal Switches DS-16M 2 and DS-32 M2 Installatio n Guide Installing the DS-16M2 an d DS-32M2 Switches CAUTION ! If you are removing the switche s from the cabi net, you mus t remove the to p switch fr om the back of the cabinet . Y ou can remove all switches be low the top switch from the front.
デバイスKraftware Corporation DS-16M2の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Kraftware Corporation DS-16M2をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはKraftware Corporation DS-16M2の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Kraftware Corporation DS-16M2の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Kraftware Corporation DS-16M2で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Kraftware Corporation DS-16M2を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はKraftware Corporation DS-16M2の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Kraftware Corporation DS-16M2に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちKraftware Corporation DS-16M2デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。