990-5520 B 05/2004 Broadband CTEP/G Seri es Zero, Three, Six Battery P ole/Ground Mount Enclo sures Four, Eigh t Battery Pole Moun t Enclosur es 120 V/ 240 V User Manual.
.
1 Chapter 1 General Informati on The CTEP/G Series Enclosures prov ide power s ourcing for broadband cabl e operations . Safety This Safety Guide contains im portant instructions that s hould be follo w ed during installat ion and maintenance of the APC equipment and batteries.
2 Chapter 2 Installation Prior to in stalling the power su pply enclosure, a u tility breaker box must be i nstalled on th e pole. Utility line voltage must be routed to the enclosure. Local, state, federal and/or National Electric Code (NE C) re gulatio ns re gar ding lo cati on, p er mits a nd ele ctri cal wirin g must be ad here d to .
3 Spec ifications Environment al Specifi cations Operating Temperature -40º F to 140º F (-40 º C to 60º C ) Humidity 5% to 95% n oncondens ing within encl osure Physical Spe cifications Characteri.
4 Installing the Enclosure Models m ay vary in app earance from thos e depicted below. Install the Mounting Br acket on a Pole CTEP0/CTEP4 models CTEP3/CTEP6/CTEP8 models Install the Enclosure on the Moun ting Bracket CTEP0/CTEP4 models Secure the bolts, nu ts, and washers on the mounted bracket prior to installing the enclosur e.
5 Ground Mount Installation 1. Install an APC approv ed concrete pad. Contact y our dealer or refer to the A PC Web site, www.apc.com f or more inf ormation. 2. Secure the enclosure to the pad. R efer to the diagrams below. 0 Battery Enclosure : Attach the ground skirt to the concrete pad.
6 Wiring Grounding 1. Install and in terconnect ground rods ap prop riate for proper grounding accordin g to local electrical code requirem ents. 2. Route groun d wires from the ground sy stem into the bus bar located on the en closure.
7 Options An optional External AC Generator Interf ace is available for the following models: CTEP3-120GI; CTEP4-12 0/240GI; C TEP/G6-120GI; CTEP8-120/ 240GI For available options s ee your dealer or the A PC Web site, www.apc.com . Connecting the Bat teries The battery circuit break er must O FF prior to battery ins tallation.
8 CTEP/G6 Botto m Shelf Middle Shelf Top Shelf.
9 CTEP4 Botto m Shelf Top Shelf.
10 CTEP8 Botto m Shelf Middle Shelf Top Shelf.
11 Chapter 3 Service, Contact and Warrant y Information Service APC makes ev ery effort to ensure parts an d equipm ent arrive in working condition. Occasionally, it may be necessary to return parts or equipment that are not in working condition. If the UPS requires service do not return it to the dealer.
12 Limited Warranty America n Power Conversi on (APC) warrant s its produ cts to be free from d efects i n materi als and workman ship for a peri od of two years from th e date of pu rchas e. Its obli gation und er thi s warranty is limited to repair ing or repla cing, at its own sole opti on, an y such defect ive p roduct s.
デバイスAPC 990-5520Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
APC 990-5520Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAPC 990-5520Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。APC 990-5520Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。APC 990-5520Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
APC 990-5520Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAPC 990-5520Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、APC 990-5520Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAPC 990-5520Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。