Page 1 12431-7-0107 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL F AN TYPE DIRECT VENT W ALL FURNACE MODEL DV -55SPP EFFECTIVE DA TE JANUAR Y 2007 Th is ap pl ia n ce ma y be in st al le d in an af te rm ar k et , pe rm an en tl y lo ca te d, man uf ac tu r ed hom e (U SA only) or mobile home, where not prohibited by state or local codes.
Page 2 12431-7-0107 SECTION P AGE Important Safety Information ......................................................................................................................3 Safety Information for Users of LP Gas .............................
Page 3 12431-7-0107 THIS IS A HEA TING APPLIANCE DO NOT OPERA TE THIS APPLIANCE WITHOUT FRONT P ANEL INST ALLED. • Due to high temperatures the appliance should be located out of traffic and away from furnitur e and draperies.
Page 4 12431-7-0107 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor .
Page 5 12431-7-0107 REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residentia.
Page 6 12431-7-0107 Introduction Always consult your local Building Department regarding regula - tions, codes or ordinances which apply to the installation of a direct vent wall furnace. Instructions to Installer 1. Installer must leave instruction manual with owner after instal - lation.
Page 7 12431-7-0107 Locating Gas Supply The gas line can enter the unit either through the floor or outside wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing.
Page 8 12431-7-0107 Clearances 1. In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper installation. 2. The DV -55 minimum wall depth is 4 1/2 inches and maximum wall depth is 13 inches.
Page 9 12431-7-0107 Locating W all Opening The furnace is to be located on an outside wall. Locate wall studs so that wall opening will be located between wall studs. The furnace is 16 inches in width and normal 16 inches on center studs will not allow the furnace to be recessed into the wall unless a stud is repositioned.
Page 10 12431-7-0107 Cutting V ent T ubes This is the most important part of the installation. With the furnace installed on wall the 6" diameter air inlet tube and the 4" diam- eter flue outlet tube are to be marked and cut using the following procedure.
Page 1 1 12431-7-0107 4. Apply furnace cement to 4" diameter flue outlet collar on combustion chamber and to 4" diameter collar on vent cap. Attach 4" diameter flue outlet tube onto flue outlet collar on combustion chamber . Attach vent cap into the 4" diameter flue outlet tube.
Page 12 12431-7-0107 1. STOP! Read the safety information above. 2. Set the thermostat to lowest setting. 3. T urn off all electric power to the appliance. 4. Remove control access panel (lower front panel). 5. T urn gas control knob clockwise to "OFF .
Page 13 12431-7-0107 The correct flame will be a short blue inner flame with a much larger light blue outer flame. The main burner (Figure 12) shows the approximate height of each part of the flame for each gas. The burner does not have a primary air adjustment.
Page 14 12431-7-0107 Figure 13 Wiring The appliance, when installed, must be electrically grounded in ac- cordance with local codes or , in the absence of local codes, with the National Electrical Code, ANSI/NFP A 70 or Canadian Electrical Code, CSA C22.
Page 15 12431-7-0107 Replacing Fan and Oiling the Motor The fan motor sho uld be cleaned and oil ed once each heatin g season. T o reach the motor, withdraw the metal shroud surrounding the fan blade by removing the screws on each side. Oil holes are located on the top at each end of the motor .
Page 16 12431-7-0107 PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. I n d ex P a r t N o . Number Description USE ONL Y MANUF ACTURER'S REPLACEMENT P ARTS. USE OF ANY OTHER P AR TS COULD CAUSE INJUR Y OR DEA TH.
Page 17 12431-7-0107 P AR TS VIEW.
Page 18 12431-7-0107 SER VICE NOTES.
Page 19 12431-7-0107 SER VICE NOTES.
Page 20 12431-7-0107 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.
デバイスLangley/Empire DV-55SPPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Langley/Empire DV-55SPPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLangley/Empire DV-55SPPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Langley/Empire DV-55SPPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Langley/Empire DV-55SPPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Langley/Empire DV-55SPPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLangley/Empire DV-55SPPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Langley/Empire DV-55SPPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLangley/Empire DV-55SPPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。