Page 1 01/13 *2P0113* 507138-01 *P507138-01* 2013 Lennox Industries Inc. Dallas, T exas, USA UPFLOW HORIZONT AL LEFT HORIZONT AL RIGHT AIR FLOW AIR FLOW AIR FLOW INST ALLA TION INSTRUCTIONS EL180U.
Page 2 Unit Dimensions - inches (mm) AIR FLOW 23 (584) (19) 3/4 (19) 1 Bottom Return Air Opening GAS PIPING INLET (Either Side) Side Return Air Opening (Either Side) 1 Bottom Return Air Opening FLUE O.
Page 3 EL180UHE Gas Furnace The E L180UHE unit is s hipped ready f or installation i n the upflow o r horizontal right position ( for horizontal left p osi tion the combustion air pressure switch must be moved) fueled b y n atural gas. A conversion kit ( ordered separate ly) i s required for u se i n L P/Propane gas applications.
Page 4 Installed in Combination with a Cooling Coil When this furnace is used with cooling units, it shall be installed in p arallel with, or on the upstream s ide of, cooling units to avoid condensation in the heating compartment.
Page 5 Do not install the furnace where drafts might blow direct ly into it. This could cause improper combustion and un safe operation. Do not block the furnace combustion air openings with clothing, boxes, doors, etc. Air is needed for proper combustion and safe unit operation.
Page 6 separated b y a door . Though an area may appear to be un confined, it might be necessary to bring in outdoor air for combustion if t he str ucture does not provide enough air by infiltration.
Page 7 EQUIPMENT IN CONFINED SP ACE ALL AIR FROM OUTSIDE (Inlet Air from Crawlspace and Outlet Air to V entilated Attic) NOTE-The inlet and outlet air openings shall each have a free area of at least one square inch (645 mm 2 ) per 4,000 Btu (1.17 kW) per hour of the total input rating of all equipment in the enclosure.
Page 8 Setting Equipment W ARNING Do not install the furnace on its front or its back. Do no t connect the return air ducts to the back of the fur nace. Doing so w ill adversely affect the operation of the safety control devices, which could result in per sonal injury or death.
Page 9 Return Air -- Upflow Applications Return air can be brought in t hrough the bottom or either side o f the furnace i nstalled i n a n u pflow a pplication.
Page 10 Removing the Bottom Panel Remov e the two screws that secure the bottom cap to the furnace. Pivot the bottom cap down to release the bottom panel.
Page 1 1 CAUTION If this unit is being installed in a space serviced by an exhaust fan, power exhaust fan, or other device which may create a negative pressure in the space, take care when sizing the inlet air opening.
Page 12 Return Air Plenum NOTE - Return air must not be drawn from a room where this furnace, or any other gas-fueled appliance (i.e., water heater), or carbon monoxide producing de vice (i.e., wood fireplace) is installed. When return air is drawn from a room, a negative pres sure i s c reated i n t he r oom.
Page 13 UPFLOW POSITION Left Side V ent Discharge FIGURE 16 Gas supply piping must be brought into the unit from the right side in order to accommodate the flue pipe.
Page 14 HORIZONT AL RIGHT POSITION T op V ent Discharge FIGURE 20 Remove make-up box assembly (2 screws) and cut wire tie to free make-up box wires.
Page 15 FLUE TRANSITION COLLAR VENT PIPE (min. 6” length) “DISCONNECTED VENT” WARNING STICKER FIGURE 22 FLUE TRANSITION COLLAR VENT CONNECTION UPFLOW AND HORIZONT AL POSITION VENT PIPE (min. 6” length) “DISCONNECTED VENT” WARNING STICKER FIGURE 23 Common V enting Using Metal-Lined Masonry Chimney 4 in.
Page 16 A type B or listed chimney lining system that passes through an unused masonry chimney flue is not considered to be exposed to the outdoors. General V enting Requirements V ent all EL180UHE fu.
Page 17 9 - If the common vertical vent is of fset, the maximum common vent capacity listed in the common venting tables should be reduced by 20%, the equivalent of two 90° elbows (0.80 x maximum common vent capacity). The horizontal length of the offset shall not exceed 1‐1/2 feet (.
Page 18 T ABLE 3 Capacity of T ype B Double-W all V ents with T ype B Double-Wall Connectors Serving a Single Category I Appliance Height H (feet) Lateral L (feet) V ent and Connector Diameter - D (in.
Page 19 T ABLE 4 V ent Connector Capacity T ype B Double-W all V ents with T ype B Double-Wall Connectors Serving T wo or More Category I Appliances V ent Height H (feet) Connector Rise R (feet) V ent.
Page 20 Removal of the Furnace from Common V ent In the event that an existing furnace is removed from a venting system commonly run with separate gas ap pliances, the venting system is likely to be too large to properly vent the remaining attached appliances.
Page 21 T ABLE 6 Gas Pipe Capacity - ft 3 /hr (m 3 /hr) Nominal Iron Pipe Size inches (mm) Internal Diameter inches (mm) Length of Pipe - feet (m) 10 (3.048) 20 (6.096) 30 (9.144) 40 (12.192) 50 (15.240) 60 (18.288) 70 (21.336) 80 (24.384) 90 (27.432) 100 (30.
Page 22 GROUND JOINT UNION DRIP LEG MANUAL MAIN SHUT-OFF VA LV E GROUND JOINT UNION DRIP LEG MANUAL MAIN SHUT-OFF VA LV E GROUND JOINT UNION DRIP LEG MANUAL MAIN SHUT-OFF VA LV E Horizontal Applicatio.
Page 23 INTERIOR MAKE-UP BOX INST ALLA TION FIGURE 28 BOX Right Side Refer to figure 2 9 for schematic wiring diagram, field wiring and trouble shooting. The power supply wiring must meet Class I restrictions. Protected by either a fuse or circuit breaker , select circuit protection and wire size according to unit nameplate.
Page 24 FIGURE 2 9 EL180UHE Schematic Wiring Diagram.
Page 25 Integrated Control RED LED Flash Code Diagnostic Codes / Status of Furnace Off No power to control or board fault detected On Board fault detected, Heartbeat 1 Control powered - displayed duri.
Page 26 Unit Start-Up FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING Do not use this furnace if any part has been under water . A flood-damaged furnace is extremely dan gerous.
Page 27 1 1 - Are flame rollout switches tripped? If flame rollout switches are tripped, call the service technician for in spection. Heating Sequence Of Operation (follow steps below or see Figure 29 for more detail) 1 - Whe n thermostat calls for heat, combustion air blower starts.
Page 28 T ABLE 10 Manifold Pressure Settings at all Altitudes Model Input Size Gas 0-2000 ft 2001-4500 ft. 4501-7500 ft 7501 - 10,000 ft Line Pressure in.wg. Min Max 045 Nat 3.5 3.2 3.0 3.5 4.5 13.0 LP/propane 10.0 10.0 10.0 10.0 1 1.0 13.0 070 Nat 3.
Page 29 HEA T F AN‐OFF TIME IN SECONDS T o adjust fan-off timing, reposition jumper across pins to achieve desired setting. NO JUMPER FIGURE 32 60 90 120 180 60 90 120 180 60 90 120 180 60 90 120 18.
Page 30 2 - Label the wires from gas valve, rollout switches, prima ry limit switch and make-up box then disconnect them. 3 - Disconnect gas supply piping.
Page 31 Start-Up & Performance Check List Unit Model Number_______________ Serial Number___________________ UNIT SET UP (typical) Gas Supply Pressure 1 2 2 1 SUPPL Y AIR Line V oltage 3 4 5 Filter RETURN AIR RETURN AIR GAS SUPPL Y Natural Gas LP/Propane Gas Piping Connections Tight Leak T ested Supply Line Pressure “ W .
Page 32 Contractor's: Name_________________________T elephone_____________Checklist Completed____________________ Job Address_____-________________________________T echnician's Name___________________________________ UNIT OPERA TION (typical) 1 HEA TING MODE GAS MANIFOLD PRESSURE “W .
デバイスLennox International Inc. EL180UHEの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lennox International Inc. EL180UHEをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLennox International Inc. EL180UHEの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lennox International Inc. EL180UHEの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lennox International Inc. EL180UHEで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lennox International Inc. EL180UHEを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLennox International Inc. EL180UHEの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lennox International Inc. EL180UHEに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLennox International Inc. EL180UHEデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。