Operation Manual Smart-UPS ® Uninterruptible Power Supply 750/1000/1500/2200/3000 V A T ower 100/120/230 V ac 500 V A T ower 100 V ac.
.
1 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Overview Product Description The APC ® by Schneider Electric Smart-UPS ® 500 V A to 3000 V A T ower is a high perform ance uninterruptible power supply (UPS).
Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 2 Product Overview Front p anel features Rear p a nel features 500 V A to 15 00 V A models Display interface 500/750/1000.
3 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Rear p a nel features 2200 V A and 30 00 V A models Inst allation For UPS installation information, refer to the Smart-UPS Installation Guide 750/1000/1500/2200/3000 V A 100/120/230 V ac, 500 V A 100 V ac T ower, that is included with the UPS.
Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 4 Operation Connect Equipment Note: The UPS will char ge to 90% capacity in th e first four and a half hours of normal operation for the 2200/3000 V A 100 V ac model or the first three hours of normal operation for all other models .
5 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Display Panel Using the display interface Use the U P and D OWN keys to scroll through th e main menu options. Press E NTER to view the sub-menus under each main menu option.
Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 6 Advanced menus The Advanced menus provid e additional options for the UPS and are available only if the display interface is configured to use the Advanced menus.
7 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Configuration UPS Settings St art-up Settings Configure these settings at initial start-up, using the di splay interface. As an a lternative, configuration can be performed using APC PowerChute ® software.
Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 8 Low T ransfer Point 100 V ac: 92 V ac 86 V ac - 92 V ac Set the transfer point lower if the utility voltage is chronically low and the connected equipment can tolerate this cond ition.
9 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Main Outlet Group and Switched Outlet Group Overview The Main Outlet Group and the Switched Outlet Grou p can be configured to independently turn of f, turn on, shut down, and reboot connecte d equipment.
Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 10 Customize the Main and Switched Outlet Groups Use the Configuration menus to change the Main Outlet Gro up and the Switched Ou tlet Group settings.
11 Smart-UPS 750/1000/1 500/2200/3000 VA 1 00/120/2 30 Vac 500 VA 100 Vac Tower Emergency Power Off Overview The Emergency Power Off (EPO) optio n, is a safety feature that will immediately disconnect all connected equipment from utility po wer . The UPS will immediately shut down and will not switch to battery powe r .
Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 12 T r oubleshooting Prob lem and Possible Cause Solution The UPS will not turn on or there is no output. The unit has not been turned on. Press the ON key once to turn on the UPS.
13 Smart-UPS 750/1000/1 500/2200/3000 VA 1 00/120/2 30 Vac 500 VA 100 Vac Tower Service If the unit requires service, do not retu rn it to the dealer . Follow these steps: 1. Review the T r ou bleshooting section of the manual to eliminate common problems.
Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 14 Smart-UPS Factory W arranty LIMITED W ARRAN TY American Power Conversion (APC ) warrants its Smart-UPS (Produc ts) to be f.
.
2/2012 990-3534C APC W orldwide Customer Support Customer support for this or any other APC product is available at no char ge in any of the follow ing ways: • V isit the APC W e b site to acce ss documents in the APC Knowledg e Base and to submit customer support requests.
デバイスAPC Smart 1000VA LCD 230Vの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
APC Smart 1000VA LCD 230Vをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAPC Smart 1000VA LCD 230Vの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。APC Smart 1000VA LCD 230Vの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。APC Smart 1000VA LCD 230Vで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
APC Smart 1000VA LCD 230Vを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAPC Smart 1000VA LCD 230Vの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、APC Smart 1000VA LCD 230Vに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAPC Smart 1000VA LCD 230Vデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。