990-3486A 01/2009 Smart-UPS ® RC External Battery Pack T ower/Rack-Mount 4U SRC96XLBP SRC96XLBP2S English.
SRC96XLBP / SRC96XLBP2S User Manual 3 Introduction Overview The American Power Conversion (APC ® ) SRC96XLBP external battery pack (XLBP) connects to an APC Smart-UPS ® RC. T ogether these units provide extended protect ion for electronic equipment (loa d) from utility power black outs, brownouts, sags and surges.
SRC96XLBP / SRC96XLBP2S User Manual 4 Specifications Environment al Specifications Physical Specifications T emperature Operating 0° to 40° C (32° to 104° F) This unit is intended for indoor use only . Select a location sturdy enough to handle the weight.
SRC96XLBP / SRC96XLBP2S User Manual 5 Inst allation Units may vary in appearance from those depicted in this manual. Always place UPS above XLBPs in rack-mount configuration. Connect all battery strings. Failur e to do so may cause equipment damage. Refer to Physical Specification s in this manual an d the Safety Guide befor e installing unit.
SRC96XLBP / SRC96XLBP2S User Manual 6 Inst all and connect b atteries This unit is equipped with batt ery modules. Install batteries into un it beginning with batteries at the bottom. Each string must be connect ed to battery connectors on chassis. 1.
SRC96XLBP / SRC96XLBP2S User Manual 7 Position unit for mounting in rack The unit is heavy . Use caution when positioning unit. NOTE: The holes for securing rack-mount brackets ar e plugged. Remove the appropriate plugs prior to installing bracke ts on the unit.
SRC96XLBP / SRC96XLBP2S User Manual 8 Inst all and connect b atteries This UPS is equipped with battery modules. Each module must be connect ed to battery connectors on chassis. 1. Install batt eries. 2. Connect internal batteries. 3. Replace battery compartmen t door and secure door with screws previously removed.
SRC96XLBP / SRC96XLBP2S User Manual 9 Connect XLBPs to UPS su22 1a UP S XLB P XLBP XLBP su222 a UP S XLBP XLBP XLBP su 26 4a T ower configuration Rack-mount configura tion There is small cover over each external battery pack connector on th e UPS and XLBP .
SRC96XLBP / SRC96XLBP2S User Manual 10 Configure UPS p arameters This configuration affects the a ccuracy of the pr edicted runtime calculations the UPS performs while running on battery power . Refer to the Battery S tring Configuration tables at the end of this s ection for detailed instructions.
SRC96XLBP / SRC96XLBP2S User Manual 11 Configure the number of battery strings using NMC terminal mod e 1. Once the blank terminal window is open : 2. Press ENTER to initiate term inal mode. Press ENTER multiple times, until the prompt User Name: is displayed.
SRC96XLBP / SRC96XLBP2S User Manual 12 Configure UPS connection sett ings using UPS terminal mo de Connect the serial cable to the seri al port on the back of the UPS. If using USB communication to the UPS, disconnect USB cable prior to conne cting serial cable.
SRC96XLBP / SRC96XLBP2S User Manual 13 Smart-UPS SRC XLI Models - Config ure Number of Battery Strings Each 96 V battery string consists of two 48 V battery modules.
SRC96XLBP / SRC96XLBP2S User Manual 14 Cont act Information APC Wo rldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: • Refer to th e APC W eb site to acc ess documents in the AP C Knowledge Base and to submit customer support requests.
SRC96XLBP / SRC96XLBP2S User Manual 15 Maintenance, T ransport, and Service Replace battery modules This UPS has easy-to-replace, hot-sw appable battery modules. Replacement is a safe procedure, isolated from electrical hazards. Y ou may leave the UPS and connected equipment on during the replacement procedure.
SRC96XLBP / SRC96XLBP2S User Manual 16 T wo-Y ear W arranty The limited warranty pr ovided by American Power Conversion (APC®) in th is statement of Limited Factory W arranty applies only to products you p urchase for your commercial or indus trial use in the ordinary co urse of your business.
デバイスAPC SRC96XLBPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
APC SRC96XLBPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAPC SRC96XLBPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。APC SRC96XLBPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。APC SRC96XLBPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
APC SRC96XLBPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAPC SRC96XLBPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、APC SRC96XLBPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAPC SRC96XLBPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。