1100AdvDigSvc REV: 3/20/08 SERVICE MANUAL (DOMESTIC) IMPINGER ADVANTAGE DIGITAL SERIES MODEL 1116-000-A, 1117-000-A, 1130-000-A, 1131-000-A, 1132-000-A, 1133-000-A WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Phone : (800) 374-3004 U.
Impinger II – Advantage Digital Service Manual - Domestic 2 SEQUENCE OF OPERATION IMPINGER II ADVANTAGE SERIAL NUMBER 2038616 AND ABOVE (OVENS WITH PUSH BUTTON CONTROLS) MODEL 1116-000-A NAT. GAS 120VAC 60 HZ. 1 PHASE MODEL 1117-000-A LP GAS 120VAC 60 HZ.
Impinger II – Advantage Digital Service Manual - Domestic 3 SEQUENCE OF OPERATION IMPINGER II ADVANTAGE SERIAL NUMBER 2038616 AND ABOVE (OVENS WITH PUSH BUTTON CONTROLS) 1130-000-A 208VAC 60 HZ. 1 PHASE 1131-000-A 240VAC 60 HZ. 1 PHASE 1132-000-A 208VAC 60 HZ.
Impinger II – Advantage Digital Service Manual - Domestic 4 SCHEMATIC DIAGRAM MODEL 1116-000-A, 1117-000-A SERIAL NUMBER 2038616 AND ABOVE.
Impinger II – Advantage Digital Service Manual - Domestic 5 SCHEMATIC DIAGRAM MODEL 1130-000-A, 1131-000-A SERIAL NUMBER 2038616 AND ABOVE.
Impinger II – Advantage Digital Service Manual - Domestic 6 SCHEMATIC DIAGRAM MODEL 1132-000-A, 1133-000-A SERIAL NUMBER 2038616 AND ABOVE.
Impinger II – Advantage Digital Service Manual - Domestic 7 TROUBLESHOOTING GUIDE GAS OVENS SERIAL NUMBER 2038616 AND ABOVE (OVENS WITH PUSH BUTTON CONTROLS) MODEL 1116-000-A NAT.
Impinger II – Advantage Digital Service Manual - Domestic 8 Main fan If not operating, refer to “Oven fan will not run”. Centrifugal switch of main fan motor Check for 120VAC at wire #5 (inp ut to centrifugal switch, located at 6-pin connecto r in ra ceway near the main fan motor) to neutral.
Impinger II – Advantage Digital Service Manual - Domestic 9 valves, the valve should open. Check for gas pressure at the manifold tap located just before the burner. If there is no pressure, check the incoming gas supply to be sure all manu al valves are open and flexible gas hose i s properly connected.
Impinger II – Advantage Digital Service Manual - Domestic 10 voltage output at the oven control, check the read- out on the control. If the control reads “P ROBE FAIL”, this indicates that the thermocouple has failed or become disconnected from the oven control.
Impinger II – Advantage Digital Service Manual - Domestic 11 wiring back to the oven power relay. If voltage is present, check for 24 VAC at the transformer secondary. If there is primary voltage but no secondary voltage, replace control tran sformer.
Impinger II – Advantage Digital Service Manual - Domestic 12 TROUBLESHOOTING GUIDE ELECTRIC OVENS 1130-000-A 208VAC 60 HZ. 1 PHASE 1131-000-A 240VAC 60 HZ. 1 PHASE 1132-000-A 208VAC 60 HZ. 3 PHASE 1133-000-A 240VAC 60 HZ. 3 PHASE SYMPTOM POSSIBLE CAUSE EVALUATION Oven fan will not run Incoming power supply Check circuit breakers.
Impinger II – Advantage Digital Service Manual - Domestic 13 oven cavity thermostat and rete st. If thermostat will not hold for maximum oven temperature, and oven is not exceeding temperature setting, check for prope r location of capillary bulb in its spring holder.
Impinger II – Advantage Digital Service Manual - Domestic 14 activate, replace the mercury contactor. Also check each contactor for hi gh voltage in put and output. Heating element(s) Check the Amp draw on each p ower le g for proper load. Check the sp ecification pla te for rating information.
Impinger II – Advantage Digital Service Manual - Domestic 15 discharge before testing. Switch, conveyor reversing Check co ntinuity between swit ch terminals. Replace switch as needed. Oven control If there is supply voltage to the motor, and the motor, capacitor, and reversing switch check good, replace the oven control.
Impinger II – Advantage Digital Service Manual - Domestic 16 REMOVAL, INSTALLATION AND ADJUSTM ENTS IMPINGER II ADVANTAGE SERIES CAUTION BEFORE REMOVING OR INSTALLING ANY COMPONENT IN THE IMPINGER OVEN BE SURE TO DISCONNECT EL ECTRICAL POWER AND GAS SUPPLY.
Impinger II – Advantage Digital Service Manual - Domestic 17 FUSE HOLDER – REPLACEMENT A. Shut off power at main breaker. B. Remove control box cover and front pa nel. C. Remove wires from fuse h o lder and ma rk for reassembly. D. Remove mounting screws or mounting n ut on fuse hol der and remove fuse holde r.
Impinger II – Advantage Digital Service Manual - Domestic 18 TRANSFORMER, BURNER – REPLACEMENT A. Shut off power at main breaker. B. Remove control panel top and front cover. C. Remove all wires from transformer and mark for re assembly. D. Remove two mounting screws from tr ansformer base and re move transformer.
Impinger II – Advantage Digital Service Manual - Domestic 19 BURNER CONTROL – REPLACEMENT A. Shut off power at main breaker. B. Remove control panel top and front cover. C. Remove wires from control and mark for reassembly. D. Remove mounting screws from control and rem ove burner control.
Impinger II – Advantage Digital Service Manual - Domestic 20 BYPASS ORIFICE – REPLACEMENT A. Shut off power at main breaker. B. Shut off gas supply to the oven and di sconnect the flexible gas line to oven. C. Remove control panel top and front cover.
Impinger II – Advantage Digital Service Manual - Domestic 21 AIR PRESSURE SWITCH – REPLACEMENT A. Shut off power at main breaker. B. Remove control panel top and front cover. C. Disconnect wiring from air pre ssure switch and mark for reassembly. D.
Impinger II – Advantage Digital Service Manual - Domestic 22 IMPINGER II ADVANTAGE GENERAL VIEW LETTER PART NUMBER DESCRIPTION A 369390 Caster 4” w/ mounting pl ate B 369502 Bottom finger cover C .
Impinger II – Advantage Digital Service Manual - Domestic 23.
Impinger II – Advantage Digital Service Manual - Domestic 24 CONTROL BOX MODEL 1116-000-A, 1117-000-A SERIAL NUMBER 2038616 AND ABOVE (OVENS WITH PUSH BUTTON CONTROLS) LETTER PART NUMBER DESCRIPTION.
Impinger II – Advantage Digital Service Manual - Domestic 25.
Impinger II – Advantage Digital Service Manual - Domestic 26 CONTROL BOX MODEL 1130-000-A, 1131-000-A, 1132-000-A, 1132-000-A SERIAL NUMBER 2038616 AND ABOVE (OVENS WITH PUSH BUTTON CONTROLS) LETTER.
Impinger II – Advantage Digital Service Manual - Domestic 27.
Impinger II – Advantage Digital Service Manual - Domestic 28 OVEN BACK ASSEMBLY LETTER PART NUMBER DESCRIPTION A 369182 Fan B 369899 Fan shroud C 369655 Stand off D Heating element 369183 208 Volt 3.
Impinger II – Advantage Digital Service Manual - Domestic 29.
Impinger II – Advantage Digital Service Manual - Domestic 30 CONVEYOR / DOOR LETTER PART NUMBER DESCRIPTION A 369611 Cou pler (S/N 2052462 & Below) B 369664 Cou pling center (S/N 2052 462 & .
Impinger II – Advantage Digital Service Manual - Domestic 31.
Impinger II – Advantage Digital Service Manual - Domestic 32.
デバイスLincoln 1117-000-Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln 1117-000-Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln 1117-000-Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln 1117-000-Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln 1117-000-Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln 1117-000-Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln 1117-000-Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln 1117-000-Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln 1117-000-Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。