MA GNUM COOLERS 1 0 -I AND 20-I OPERA TOR’S MANUAL IM438-B March, 1999 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ..
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv PRÉCA UTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instruc- tions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suivantes: Sûreté Pour Soudage A L’Arc 1.
v v EXPLANA TION OF SYMBOLS THA T APPEAR ON THIS EQUIPMENT OFF ON O Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company .
vi T ABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications .........................................................................
A-1 INST ALLA TION MAGNUM COOLER 10-I & 20-I A-1 TECHNICAL SPECIFICA TIONS – MA GNUM COOLERS 10-I AND 20-I Model Cooler 10-I Cooler 20-I Product No. K873-1 K879-1 Input 220V 50/60 Hz 1 Phase 220V 50/60 Hz 1 Phase Current Draw at Input .75 Amps 1.
A-2 INST ALLA TION MAGNUM COOLER 10-I & 20-I A-2 PRODUCT DESCRIPTION Magnum Coolers 10-I and 20-I are stand alone recir- culating cooling systems designed for use with water cooled TIG, MIG, PAC (Plasma Arc Cutting) and PAW (Plasma Arc Welding) guns and torches.
A-3 INST ALLA TION MAGNUM COOLER 10-I & 20-I A-3 INST ALLA TION PRODUCT OVERVIEW The LIGHTED POWER SWITCH is located at the left side of the control panel (A). Cooler will be “ON” when pressed to “ | “. Coolant INLET and OUTLET fittings are found at the rear of the unit (B).
A-4 INST ALLA TION MAGNUM COOLER 10-I & 20-I A-4 When using the Magnum Cooler with other products, consult the manufacturer’s recommendations for coolant. Do not use oil based coolants. The unit can be filled either vertically or horizontally. UNPLUG THE COOLER BEFORE FILLING THE RESERVOIR.
A-5 INST ALLA TION MAGNUM COOLER 10-I & 20-I A-5 Cooler and insert the nipple into the connector nut so that the threaded end of the connector nut points away from the barbed end of the nipple. Twist the barbed end of the nipple into the hose until the shoulder of the nipple is flush with the end of the hose.
A-6 INST ALLA TION MAGNUM COOLER 10-I & 20-I A-6 2. Route all water line connections onto connection block at back of Cooler as outlined in the IM manual provided with the Magnum Cooler. Self Tapping Screw (4 req'd) W ARNIN G ON COOLERS 20 & 20-I : Align holes A & B of mounting bracket with holes A & B of Magnum Cooler.
A-7 INST ALLA TION MAGNUM COOLER 10-I & 20-I A-7 A POWER SOURCE HEIGHT 16.44" (417.6mm) POWER SOURCE HEIGHT 21.50" (546.1mm) B E POWER SOURCE HEIGHT 27.50" (698.5mm) POWER SOURCE HEIGHT 21.50" (546.1mm) D POWER SOURCE HEIGHT 16.
A-8 INST ALLA TION MAGNUM COOLER 10-I & 20-I A-8 WATER COOLED EQUIPMENT INSTALLATION NOTE: Magnum Coolers operate at 45 psi (3.0 bar) (310 kPa) of pressure for Cooler 10-I and 60 psi (4.
A-9 INST ALLA TION MAGNUM COOLER 10-I & 20-I A-9 FIGURE 5 Water Cooled MIG Gun Connection FIGURE 6 Water Cooled Plasma System Connection COOLANT IN COOLANT OUT COOLANT COOLANT GUN CABLE COOLANT IN.
A-10 INST ALLA TION MAGNUM COOLER 10-I & 20-I A-10 K440-1 LN-7 GMA WIRE FEEDER WITH GAS AND WATER SOLENOID VALVE The K440-1 LN-7 GMA wire feeder is equipped with internal water lines and external connectors for attach- ment to a water cooled MIG gun and a Magnum Cooler.
A-11 INST ALLA TION MAGNUM COOLER 10-I & 20-I A-11 K529-10 POWER INPUT CABLE WITH WATER AND GAS LINES The K529 power input cable connects from the front of a Lincoln power source to the back of LN-7 and LN-7 GMA wire feeders equipped with a water solenoid control.
B-1 OPERA TION B-1 SAFETY PRECAUTIONS - Even when using the Magnum Cooler in an “on- demand” application, the power to the Cooler should be turned off when welding is not taking place for a long period of time.
B-2 OPERA TION B-2 You will be able to hear the fan running and feel air flow out of the back of the unit when the Cooler is operating. The Cooler will run continuously when operated without a water solenoid or valve.
B-3 OPERA TION B-3 - Abrasion failure due to particulate in coolant. - Corrosion failure due to deionized water and pure glycol mixtures. - Cavitation failure due to air bubbles introduced by an intake screen ( or any other source). - Dry operation failure due to the reservoir being emp- tied.
B-4 OPERA TION B-4 MAGNUM COOLER 10-I & 20-I FIGURE 9 Circulation of Magnum Cooler T ABLE 3 Approximate Cooling Rate and Recommended Use (1) ROOM AIR IN HEATED AIR OUT HEAT EXCHANGER FAN PUMP COOLANT RETURN COOLANT INTAKE COOLANT COOLANT NOTE: COOLANT OUT COOLANT IN = = BLUE HOSE RED HOSE Model Cooler 10-I Cooler 20-I Product No.
C-1 A CCESSORIES C-1 PARTS DESCRIPTION FOR MAGNUM COOLER ACCESSORIES S20095-1 Pump Replacement Kit (60 psi) (4.0 bar) (414 kPa) for Magnum Cooler 20-I Models Includes: * (1) Complete 40-60 psi (3.0-4.0 bar) (310-414) kPa) Pressure switch assembly. * (1) Complete 60 psi (4.
D-1 MAINTENANCE D-1 HEAT EXCHANGER MAINTENANCE To maintain maximum efficiency, the heat exchanger should be kept clean from dust and dirt buildup. Clean the heat exchanger periodically using a vacuum hose or low pressure air line. Avoid placing the unit near a flux hopper or a flux waste container.
E-1 TR OUBLESHOO TING E-1 MAGNUM COOLER 10-I & 20-I TR OUBLESHOO TING GUIDE This Troubleshooting Guide is designed to be used by the machine Owner/Operator. Unauthorized repairs per- formed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty.
a. Power cord unplugged. b. No power at outlet. c. Power cordset damaged. d. Unit too hot. Thermal protector tripped. e. Water lines blocked or crimped. f. Unit is used in a demand system and water valve or solenoid dam- aged. g. Leak in gun or water hoses.
E-3 TR OUBLESHOO TING E-3 MAGNUM COOLER 10-I & 20-I Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-4 TR OUBLESHOO TING E-4 MAGNUM COOLER 10-I & 20-I Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
F-1 DIA GRAMS F-1 MAGNUM COOLER 10-I & 20-I .
+ - + - FAN MOTOR MOTOR PUMP FAN MOTOR MOTOR PUMP M M L M M M L V 115 Hz 60 V Hz 220 50/60 COOLER 10 COOLER 10-I V 115 Hz 60 V Hz 220 50/60 COOLER 20 COOLER 20-I COOLER 10 & 10-I WIRING DIAGRAM CO.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS P AR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
デバイスLincoln Electric IM438-Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln Electric IM438-Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln Electric IM438-Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln Electric IM438-Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln Electric IM438-Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln Electric IM438-Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln Electric IM438-Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln Electric IM438-Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln Electric IM438-Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。