LN-35 C V/CC SEMIA UTOMA TIC WIRE FEEDER OPERA TOR’S MANUAL IM812-A January, 2005 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation .
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv Mar. ‘93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi vi T ABLE OF CONTENTS Page INSTALLATION SECTION ......................................................................................................................A Technical Specifications .......................................................
A-1 INST ALLA TION LN-35 A-1 TEMPERA TURE RANGE OPERA TION: - 40 o C to +40 o C (- 40 o F to +104 o F) STORAGE: - 40 o C to +85 o C (- 40 o F to +185 o F) OPERA TING ARC VOL T AGE Constant Voltage (CV.
A-2 INST ALLA TION LN-35 A-2 ELECTRIC SHOCK can kill. • Do not operate with covers removed. • Turn off power source before installing or servicing. • Do not touch electrically hot parts. • Turn the input power to the welding power source off at the fuse box before working in the terminal strip.
A-3 INST ALLA TION LN-35 A-3 c. Set ELECTRODE POLARITY switch to constant voltage polarity required by electrode. d. Set toggle switch to “Constant Voltage” and set the Constant Voltage Control on welder and the portable field control on #5 for initial start.
A-4 INST ALLA TION LN-35 A-4 WELD CABLE CONNECTION The size of the electrode cable and work cable must be sufficient for the maximum weld current and total cable length to be used.
B-1 OPERA TION LN-35 B-1 ELECTRIC SHOCK can kill. • Do not touch electrically live part or electrode with skin or wet clothing. • Insulate yourself from work and ground. • Always wear dry insulat- ing gloves. ARC RAYS can burn. • Wear eye, ear and body protection.
B-2 OPERA TION B-2 LN-35 TO MOUNT A 50 OR 60 LB COIL: 1. To remove the wire reel from its shaft. 2. Lay the reel flat on the floor. Loosen the spinner nut and remove the cover plate. See Figure B.1. 3 . Place the coil of electrode on the reel so it unwinds as the reel rotates clockwise.
B-3 OPERA TION B-3 e. Press the gun trigger and push the electrode until it just enters the drive roll. When inching with gun trigger, the electrode and drive mechanism are always “hot” to work and ground. --------------------------------------------------------------------- f.
B-4 OPERA TION B-4 LN-35 PRESETTING WIRE FEED SPEED The LN-35 permits accurate presetting of the desired wire feed speed, before welding, in both CV and CC wire feed modes. SETTING CONSTANT WIRE FEED SPEED ( C V MODE) a. Set Wire Feed Mode switch to CV position.
B-5 OPERA TION B-5 MAKING A WELD SETUP a. Connect work cable to metal to be welded. Work cable must make good electrical contact to the work. The work must also be grounded as stated in “Arc Welding Safety Precautions.
B-6 OPERA TION B-6 a . Cut the electrode within approximately 3/8”(9.5mm) of the end of the contact tip for solid wire and within approximately 3/4”(19.1mm) of the extension guide for cored wire. b. Position electrode over joint. End of electrode should be slightly off the work.
B-7 OPERA TION B-7 CC (formerly VV) power sources, on the other hand, permit the arc voltage to decrease with increases in welding current. The output characteristics of these power sources can range .
D-1 MAINTENANCE D-1 LN-35 SAFETY PRECAUTIONS Have qualified personnel do the maintenance work. Turn the engine off before working inside the machine. In some cases, it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete.
D-2 MAINTENANCE D-2 ADJUSTING SPEED SENSOR MODULE The LN-35 Speed Sensor Module is a three lead Hall Effect switch device encased in an externally threaded housing which is screwed into a mounting plate on the motor side of the wire drive gearbox.
E-1 TROUBLESHOOTING E-1 LN-35 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TROUBLESHOOTING E-2 LN-35 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-3 TROUBLESHOOTING E-3 LN-35 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
F-1 DIAGRAMS F-1 LN-35 632 633 631 10KW R1 WIRE SPEED CONTROL RHEOSTAT S3 S1 TO WORK CABL E BLACK POS 667 621 NEG A B C D E 622A 500A J5 TRIGGER CONNECTOR 7 * * J3 J14 3 2 1 4 2 1 3 4 621 500A 667 622.
NOTES LN-35.
W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS PAR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
デバイスLincoln Electric IM812-Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln Electric IM812-Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln Electric IM812-Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln Electric IM812-Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln Electric IM812-Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln Electric IM812-Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln Electric IM812-Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln Electric IM812-Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln Electric IM812-Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。