Lincoln ElectricメーカーImpinger Advantage Digital Series 1154-000-EAの使用説明書/サービス説明書
ページ先へ移動 of 32
1100ExAdDig REV: 11/4/08 SERVICE MANUAL (INTERNATIONAL) IMPINGER ADVANTAGE DIGITAL SERIES MODEL 1154-000-EA, 1155-000-EA, 1164-000-EA WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Phone : (800) 374-3004 U.
Impinger II – Advantage Digital Service Manual - International 2 SEQUENCE OF OPERATIONS IMPINGER II ADVANTAGE SERIAL NUMBER 2038616 AND ABOVE (OVENS WITH PUSH BUTTON CONTROLS) MODEL 1154-000-EA NAT. GAS 230VAC 50 HZ. 1 PHASE MODEL 1155-000-EA LP GAS 230VAC 50 HZ.
Impinger II – Advantage Digital Service Manual - International 3 SEQUENCE OF OPERATIONS IMPINGER II ADVANTAGE SERIAL NUMBER 2038616 AND ABOVE (OVENS WITH PUSH BUTTON CONTROLS) MODEL 1164-000-E A 400/230VAC 50HZ. 3 PHASE POWER SUPPLY Electrical power to be supplied to the ov en by a four con ductor service.
Impinger II – Advantage Digital Service Manual - International 4 SCHEMATIC DIAGRAM MODEL 1154-000-EA, 1155-000-EA SERIAL NUMBER 2038616 TO 2045407.
Impinger II – Advantage Digital Service Manual - International 5 SCHEMATIC DIAGRAM MODEL 1154-000-EA, 1155-000-EA SERIAL NUMBER 2045408 AND ABOVE.
Impinger II – Advantage Digital Service Manual - International 6 SCHEMATIC DIAGRAM MODEL 1164-000-EA SERIAL NUMBER 2038616 AND ABOVE.
Impinger II – Advantage Digital Service Manual - International 7 SCHEMATIC DIAGRAM MODEL 1164-000-EA SERIAL NUMBER 2053336 AND ABOVE (RoHS Compliant).
Impinger II – Advantage Digital Service Manual - International 8 TROUBLESHOOTING GUIDE IMPINGER II ADVANTAGE SERIAL NUMBER 2038616 AND ABOVE (OVENS WITH PUSH BUTTON CONTROLS) MODEL 1154-000-EA NAT. GAS 230VAC 50 HZ. 1 PHASE MODEL 1155-000-EA LP GAS 230VAC 50 HZ.
Impinger II – Advantage Digital Service Manual - International 9 blockage or damage. If above checks are okay, but pressure switch is still not closed, replace gas valve. Air pressure switch Check air switch terminals for sup ply voltage to terminals NO2 and COM.
Impinger II – Advantage Digital Service Manual - International 10 Power supply Set the temperature to the lowest temperature setting. If there is sufficient microamp current, but the flame will not stay lit, check for pr oper polarity of the power supply.
Impinger II – Advantage Digital Service Manual - International 11 shorts. Readings should b e as follo ws, V1 – 2.9K ohms approx., V2 – 1.3K ohms appr ox. If these readings are not achieved, replace gas valve. If these readings are achieved, replace ignition control.
Impinger II – Advantage Digital Service Manual - International 12 should be approx. 25-100 Hz. If these readin gs a re n ot achieved, replace conveyor motor.
Impinger II – Advantage Digital Service Manual - International 13 terminals. Replace as needed. Cooling fan Line voltage should now be at the cooli ng fan. If voltage is present, check motor for opens, sh orts or grounds. With power off, check for locked roto r.
Impinger II – Advantage Digital Service Manual - International 14 connected to the oven control, and the display indi cate s “PROBE FAIL”, disconnect the thermocouple from the oven control and measure the resi stance of the thermocouple. The thermocou ple should read approx.
Impinger II – Advantage Digital Service Manual - International 15 Control transformer Chec k for supply voltage to the primary of control transformer. If no voltage is present, trace wiring b ack to oven fan switch. If voltage is present, check for 24VAC at transformer secondary.
Impinger II – Advantage Digital Service Manual - International 16 REMOVAL, INSTALLATION AND ADJUSTM ENTS IMPINGER II ADVANTAGE SERIES CAUTION BEFORE REMOVING OR INSTALLING ANY COMPONENT IN THE IMPINGER OVEN BE SURE TO DISCONNECT EL ECTRICAL POWER AND GAS SUPPLY.
Impinger II – Advantage Digital Service Manual - International 17 FUSE HOLDER – REPLACEMENT A. Shut off power at main breaker. B. Remove control box cover and front pa nel. C. Remove wires from fuse h o lder and ma rk for reassembly. D. Remove mounting screws or mounting n ut on fuse hol der and remove fuse holde r.
Impinger II – Advantage Digital Service Manual - International 18 TRANSFORMER, CONT ROL – REPLACEMENT A. Shut off power at main breaker. B. Remove control panel top and front cover. C. Remove all wires from transformer and mark for re assembly. D.
Impinger II – Advantage Digital Service Manual - International 19 A. Shut off power at main breaker. B. Remove control panel top and front cover. C. Remove wires from control and mark for reassembly. D. Remove one mounting screw and rem ove burner control from the gas valve.
Impinger II – Advantage Digital Service Manual - International 20 TEMPERATURE REGULATION VALVE – REPLACEMENT A. Shut off power at main bre ake r. B. Shut off gas supply to the oven and di sconnect the flexible gas line to oven. C. Remove control panel top and front cover.
Impinger II – Advantage Digital Service Manual - International 21 A. Shut off power at oven switch. B. Set conveyor reversing switch in the other position. C. Turn oven “on” and chec k for pro per operation. CAPACITOR, CONVEYOR DRIVE MOTOR – REPLACEMENT A.
Impinger II – Advantage Digital Service Manual - International 22 IMPINGER II ADVANTAGE GENERAL VIEW LETTER PART NUMBER DESCRIPTION A 369390 Caster 4” w/mounting plate B 369502 Bottom finger cover.
Impinger II – Advantage Digital Service Manual - International 23.
Impinger II – Advantage Digital Service Manual - International 24 IMPINGER II ADVANTAGE CONTROL BOX 1154-000-EA, 1155-000-EA LETTER PART NUMBER DESCRIPTION A 370108 Control box top B 370355 Control,.
Impinger II – Advantage Digital Service Manual - International 25.
Impinger II – Advantage Digital Service Manual - International 26 IMPINGER II ADVANTAGE CONTROL BOX 1164-000-EA LETTER PART NUMBER DESCRIPTION A 370108 Control box top B 370355 Control, oven C 36943.
Impinger II – Advantage Digital Service Manual - International 27.
Impinger II – Advantage Digital Service Manual - International 28 OVEN BACK ASSEMBLY LETTER PART NUMBER DESCRIPTION A 369182 Fan B 369899 Fan shroud C 369655 Stand off D 3701 64 Heating element 230 .
Impinger II – Advantage Digital Service Manual - International 29.
Impinger II – Advantage Digital Service Manual - International 30 CONVEYOR / DOOR LETTER PART NUMBER DESCRIPTION A 369611 Coupler (S/N 2052462 & Below) B 369664 Coupling center (S/N 2052 462 &am.
Impinger II – Advantage Digital Service Manual - International 31.
Impinger II – Advantage Digital Service Manual - International 32.
デバイスLincoln Electric Impinger Advantage Digital Series 1154-000-EAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln Electric Impinger Advantage Digital Series 1154-000-EAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln Electric Impinger Advantage Digital Series 1154-000-EAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln Electric Impinger Advantage Digital Series 1154-000-EAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln Electric Impinger Advantage Digital Series 1154-000-EAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln Electric Impinger Advantage Digital Series 1154-000-EAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln Electric Impinger Advantage Digital Series 1154-000-EAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln Electric Impinger Advantage Digital Series 1154-000-EAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln Electric Impinger Advantage Digital Series 1154-000-EAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。