SWR - SWC - SWD Swing Gate Oper ator Installation Guide USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - T oll Free FAX (800) 468-1340 www .
SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 Revision X13 3-28-2008 T able of Contents Pre-installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Before Y ou Begin... . . . . . . . . . . . .
SWR • SWC • SWD Swing Gate Operator Installation Guide - 1 - 227965 Revision X13 3-28-2008 Pre-installation Information Before Y ou Begin... Bef ore unpacking, inspect the car ton f or exterior damage. If you fi nd damage, advise the deliv er y carrier of a potential claim.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 2 - 227965 Revision X13 3-28-2008 Wiring Specifi cations Ref er to the follo wing steps for details on po wer and accessor y wiring for the operator . AC P ower Wiring 1. Find the listing on this page corresponding to the model, voltage and horsepower r ating of your operator .
SWR • SWC • SWD Swing Gate Operator Installation Guide - 3 - 227965 Revision X13 3-28-2008 Mounting P ad Installation The gate operator mounts bolted to a custom poured concrete mounting pad. The pad suppor ts the operator and pre vents it from twisting during operation.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 4 - 227965 Revision X13 3-28-2008 Operator Prepar ation Vent Plug Installation In order to keep gear oil from spilling out during shipping, gear reducers used in gate operators ha ve either a solid plug, or a sealed v ent plug, installed at the factory .
SWR • SWC • SWD Swing Gate Operator Installation Guide - 5 - 227965 Revision X13 3-28-2008 Gate Arm Installation (Cont.) Choosing Good Harmonics Good har monics are necessar y to minimize wear and tear on the operator . The gate will hav e smoother star ts and stops when the ar m is installed with good har monics.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 6 - 227965 Revision X13 3-28-2008 Operator Setup Controller Access The Controller in models SWR, SWC and SWD is hinged f or access and can be remov ed without taking off the operator’ s cov er .
SWR • SWC • SWD Swing Gate Operator Installation Guide - 7 - 227965 Revision X13 3-28-2008 Operator Setup (Continued) Limit Cam Rough Adjustment The limit cams are not preset at the f actor y and must be adjusted f or each installation. The limit switches are activ ated by two rotating limit cams attached to the drive shaft (see Figure 10).
SWR • SWC • SWD Swing Gate Operator Installation Guide - 8 - 227965 Revision X13 3-28-2008 Controller Features S HADOW/ R E S ET P R O GR AMMIN G B UTTON S POWE R INDICATO RS DI S PLAY WHIP ANTENN.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 9 - 227965 Revision X13 3-28-2008 Indicator Descriptions INDICA TOR DEFINITION INDICA TION WHEN LIT DURING NORMAL OPERA TION INDICA TION WH.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 10 - 227965 Revision X13 3-28-2008 T erminal Descriptions TERMINAL GROUP FUNCTION AC N 24 V OL T INPUT F ACT OR Y CONNECTED T O 24 V A C FROM TRANSFORMER OR 24 VDC FROM CONTINUOUS DUTY DC SUPPL Y .
SWR • SWC • SWD Swing Gate Operator Installation Guide - 11 - 227965 Revision X13 3-28-2008 Operator Accessory Connections 3-BUTTON STATION KEYSWITCH FIRE ACCESS SWITCH SINGLE-CHANNEL RADIO RECEIV.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 12 - 227965 Revision X13 3-28-2008 Basic Controller Programming Progr amming Overview The Controller can be programmed with v arious options for the operator . The programming fi elds are defi ned as “functions” that ha ve “options”.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 13 - 227965 Revision X13 3-28-2008 Basic Controller Programming (Cont.) Run Alarm and Pre-start Alarm The factory default is Run Alarm on and a 3-second Pre-star t Alar m. The operator’ s beeper will sound 3 seconds before the operator star ts.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 14 - 227965 Revision X13 3-28-2008 Advanced Controller Progr amming Entering Advanced Progr amming Mode T o access and program the Adv anced Programming functions, f or each programming session, Adv anced Programming must be enab led.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 15 - 227965 Revision X13 3-28-2008 Advanced Controller Progr amming (Cont.) Auxiliary Relay Mode The Auxiliary Relay has normally open and normally closed contacts. The factory setting disables the A uxiliar y Relay .
SWR • SWC • SWD Swing Gate Operator Installation Guide - 16 - 227965 Revision X13 3-28-2008 Advanced Controller Progr amming (Cont.) Soft Start/Stop Duration This function is only used with DC swing gate Model SWD .
SWR • SWC • SWD Swing Gate Operator Installation Guide - 17 - 227965 Revision X13 3-28-2008 Advanced Controller Progr amming (Cont.) Radio Enable The Controller contains a built-in MegaCode ® radio receiv er to allow activation from up to 40 access control tr ansmitters and two Model MGT (gate edge) transmitters.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 18 - 227965 Revision X13 3-28-2008 Loop Lay out Illustration 2" 3 / 8 " U S E R ELIEF CUT S AT CO R NE RS TWI S T WI R E F R OM END OF LOOP S B ACK TO OPE R ATO R AT LEA S T S IX TIME S PE R FOOT 2" MAX.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 19 - 227965 Revision X13 3-28-2008 Safety Edge Lay out Illustration R ECEIVE R IN S IDE G ATE OPE R ATO R G ATE ED G E T R AN S MITTE R S EPA R ATE PEDE S T R IAN G ATE R EQUI R ED 7FT.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 20 - 227965 Revision X13 3-28-2008 Photoey e Installation Illustration S EPA R ATE PEDE S T R IAN G ATE R EQUI R ED 7 FT.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 21 - 227965 Revision X13 3-28-2008 Dual Gate Installations T w o operators can be used in dual gate installations. The operators communicate with each other through the 3-wire COMM LINK ter minals.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 22 - 227965 Revision X13 3-28-2008 Operation Indications During nor mal operation, the Controller’ s displa ys will indicate current operating conditions and status .
SWR • SWC • SWD Swing Gate Operator Installation Guide - 23 - 227965 Revision X13 3-28-2008 T roubleshooting Contacting T echnical Support For technical questions regarding Linear gate oper ators, contact the T echnical Ser vices Depar tment at: 1-800-421-1587 fr om 6:30 AM to 4:30 PM P acifi c time Operator fails to start A.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 24 - 227965 Revision X13 3-28-2008 Model SWR Exploded View 3 A 3B 2 6 25 4 20 22 17 2 3 15 1 3 A 1 3 C 1 3B 12 3 8 9 7 5 11 7A 7 B 10 14 1 3 2 1 6 1 19 1 8 MODEL SWR MECHANICAL P ARTS LIST REF .
SWR • SWC • SWD Swing Gate Operator Installation Guide - 25 - 227965 Revision X13 3-28-2008 Model SWC Exploded View 3 1 3 C 1 3 A 1 3B 15 12 1 6 2 10 14 1 3 19 2 6 22 17 1 8 20 2 3 4 25 1 3B 3 A 9 8 7 11 5 MODEL SWC MECHANICAL P ARTS LIST REF .
SWR • SWC • SWD Swing Gate Operator Installation Guide - 26 - 227965 Revision X13 3-28-2008 MODEL SWD MECHANICAL P ARTS LIST REF . # P ART # DESCRIPTION 1 2300-925-BEIGE Operator Cov er, T an 2300.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 27 - 227965 Revision X13 3-28-2008 GA TE ARM ASSEMBL Y MECHANICAL P ARTS LIST REF . # P ART # DESCRIPTION 2120-493 Complete Ar m Assembly 1.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 28 - 227965 Revision X13 3-28-2008 1 R EMOVE BR U S H R ETAININ G CAP WITH FLAT B LADE S C R EWD R IVE R 4 5 2 3 PULL ON CONTACT TO R EMOVE.
SWR • SWC • SWD Swing Gate Operator Installation Guide - 29 - 227965 Revision X13 3-28-2008 Prev entative Maintenance General Linear gate operators are designed f or many y ears of trouble-free oper ation and, under recommended operating conditions, will require only minimal maintenance .
SWR • SWC • SWD Swing Gate Operator Installation Guide - 30 - 227965 Revision X13 3-28-2008 INST ALLER CUSTOMER Customer’ s Signature Installer’ s Signature Date Date Gate Operator Installation Checklist ❑ ❑ 1. The gate has been chec ked to make sure it is le vel and mov es freely in both directions.
デバイスLinear SWCの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Linear SWCをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLinear SWCの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Linear SWCの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Linear SWCで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Linear SWCを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLinear SWCの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Linear SWCに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLinear SWCデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。