Solar Pump Station Installation and Operation Manual SPS0250, SPS0500 & SPS1000 This manual must only be used by a qualified heating installer/ service technician. Read all instructions, before installing. Perform steps in the order given. Failure to comply could result in severe personal injury, death, or substantial property damage.
2 Hazard definitions The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels or to important information concerning the life of the product.
3 1 General Information Before starting work, the Installer must read, understand and note these installation and operating instructions. WARNING The solar pump station may only be installed and maintained by trained professionals. Trainees may only work on the product under the supervision of an experienced person.
4 Included Components Solar Station: ■ Grundfos solar circulation pump ■ VFS sensor (flow sensor) ■ 145 psi relief valve, with pressure gauge ■ Multi-function instruments (Flow Check, Thermome.
5 2 Installing the solar station Installing the solar station on a wall ■ Remove front insulation shell. ■ The solar pump station forms a single unit with the wall bracket and rear insulation shell.
6 3 Technology, installation and commissioning Clamp ring screw connections ■ Cut the copper pipe to length and deburr. ■ First, slide the clamp ring nut over the pipe, then slide the clamp ring. ■ Insert the prepared pipe into the screw connection until its stop is reached.
7 4 Commissioning the solar system General ■ Before commissioning, all piping, connections and saftey equipment should be checked to ensure that they are correctly installed. ■ All pre-fitted solar station screw connections are firmly tightened in the factory so that they do not usually need retightening.
Solar group with Grundfos UPS 25-58U pump (and GF sensor 0.5-3 GPM) residual delivery height 0 5 10 15 20 25 0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 V olumetric flow rate [GPM] Residual delivery height [Ft] Max. residual delivery height pressure drop of components Solar group with Grundfos UPS 25-99U pump (and GF-Sensor 0.
9 6 VFS flow sensor Figure 6-1 VFS 1-12 flow ouput signal VFS 1-12 output signal ow Assignment of m easurement range: 0.26-3.17 gpm i s eq ual to 0.5-3.5V Flow rate calculation: Q = 0.26gpm + [(U-0.5)V/3V]*2 .91gpm Figure 6-3 VFS 2-40 flow output signal VFS 2-40 output signal ow Assignment of m easurement range: 0.
10 7 Technical data for solar station Designation SPS0250 / SPS0500 SPS1000 PUMP SPS0250: Grundfos UPS 25 - 58 U SPS1000: Grundfos U P 2 5 - 120 U SPS0500: Grundfos UPS 25 - 99 U SOLAR AND TANK CONNEC.
11 7 Technical data for solar station (continued) Designation SPS0250 / SPS0500 SPS1000 GRAVITY BRAKES Installation location: forward flow and return ball valves Material: Brass Seal: O-ring 70 EPDM 2.
8 Component breakdown 20 3 2 4+5 12+15 25 8+9 22 14 11 23 16 13 26 30 27 24 4 6 17 19 1 10 18 7+9 21 SPS0250/ SPS0500 Item Name – SPS0250 - Pumpstation 250 sq-ft w/ flow sensor and CU – SPS0500 - Pumpstation 500 sq-ft w/ flow sensor and CU 1 Solar return ball valve USA 1 1/2" x M28 x 1.
2 27 4+5 3 19 30 31 11 6+7 9 13 21 4 12 29 17 20+22 10 24 1 18 23 32 8 25 16 26 28 33 34 35 Figure 9-2 SPS1000 8 Component breakdown (continued) 13 SPS1000 Item Name – Pumpstation 1000 sq-ft w/ flow sensor and CU 1 Solar return ball valve 1 1/2" Fl.
14 9 Service De-energize and lock the solar control and pump to prevent them from accidentally being switched back on again by mistake before any maintenance or repair work. Service is not permitted until components and solar liquid have cooled. WARNING ■ The solar station features an air separator.
15 10 Faults, causes and rectification Pump doesn’t run when power is switched on : ■ Check solar control unit for correct settings and tight wire connections. ■ Check fuses. ■ Check pump voltage, refer to the pump rating plate for requirements.
Revision Notes: Revision A (ECO C06520) initial release. Revision B (ECO C07610) reflects formatting adjustments. SL-PS-I-O Rev B 3/11.
デバイスLochinvar TISUN PS1000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lochinvar TISUN PS1000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLochinvar TISUN PS1000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lochinvar TISUN PS1000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lochinvar TISUN PS1000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lochinvar TISUN PS1000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLochinvar TISUN PS1000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lochinvar TISUN PS1000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLochinvar TISUN PS1000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。