Manual Humidifier Control Safety and Installation Instructions WARNING A TTENTION INST ALLER: This product must be installed by a qualified heating and air conditioning contractor . Failure to do so could result in serious injury from electrical shock.
2 WARNING 1. 120 volts may cause serious injury from electrical shock. Disconnect electrical power to the furnace before starting installation. 2. Sharp edges may cause serious injury from cuts. Use care when cutting plenum openings and handling ductwork.
3 LOCA TION For Wall Mount: • Locate on an inside wall of living area approximately 5’ above the floor . • Do not locate control in the direct path of drafts from open doors and windows. • Do not install where operation might be affected by lamps, sunlight, fireplace, registers, radiators, concealed air ducts and pipes, or room occupants.
4 INST ALLING AND WIRING Wall Installation: 1. Select location for the Humidifier Control on an inside wall. Mount the Humidifier Control in a location where low voltage wires from the furnace area are already in place, or can be easily run. 2. Drill a 1/2” hole into the wall at the selected Humidifier Control location.
5 ANCHOR F (x2) SCREW E (x2) BASE PLA TE D HUMIDIST A T SWITCH C COVER B KNOB A BASE PLA TE D Figure 1 – Wall Mount 90-1228.
6 Duct (sheet metal) Installation: 1. Select Humidifier Control location on furnace return air duct. 2. Use the attached template to mark the duct opening. 3. Carefully cut the opening in the duct. 4. (See Figure 2 ) Gently pull knob (A) from Humidifier Control cover (B).
7 SCREW H (x4) INSIDE OF RETURN DUCT GASKET G BASE PLATE D HUMIDISTAT SWITCH C COVER B KNOB A RETURN DUCT Figure 2 – Sheet Metal Duct Mount 90-1229.
8 Duct (fiber board) Installation: 1. Select Humidifier Control location on furnace return air duct. 2. Cut a rectangular hole in the duct board, no smaller than 5-3/4 inches long by 3-3/4 inches wide. 3. Cut a rectangular piece of sheet metal to fit behind the hole in duct board for mounting the Humidifier Control.
9 KNOB A SHEET MET AL PLA TE CUT OPENING IN RETURN DUCT RETURN DUCT SHEET MET AL PLA TE RETURN DUCT BASE PLA TE D COVER B HUMIDIST A T SWITCH C GASKET G SCREW H (x4) INSIDE OF RETURN DUCT Figure 3 –.
10 SPECIFICA TIONS RANGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15% to 50% OPERA TIONAL DIFFERENTIAL . . . . . . . . . . . 8% RH NOMINAL DIMENSIONS (Inches) Length . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11 INST ALLA TION TEMPLA TE TEMPLA TE SIZE: 4-5/32” x 2-7/16” 1. CUT OUT TEMPLA TE ALONG EDGES. 2. PLACE TEMPLA TE ON THE SHEET MET AL RETURN PLENUM UPSTREAM OF (BEFORE) THE HUMIDIFIER CONNECTION. 3. TRACE OUTSIDE EDGES OF TEMPLA TE. 4. REMOVE TEMPLA TE AND ACCURA TEL Y CUT OPENING.
RESEARCH PRODUCTS CORPORA TION P .O. BOX 1467 • MADISON,WI 53701-1467 Call 800/334-6011 • FAX 608/257-4357 10007235 8.07 B2204275A Printed in USA.
デバイスAprilaire 4655の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Aprilaire 4655をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAprilaire 4655の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Aprilaire 4655の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Aprilaire 4655で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Aprilaire 4655を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAprilaire 4655の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Aprilaire 4655に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAprilaire 4655デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。