Manitowoc Iceメーカー11Mの使用説明書/サービス説明書
ページ先へ移動 of 42
Installation, Use & Care Manual This manual is updated as new information and models are released. Visit our website for the latest manual. www.manitowocfsg.
We reserve the right to make product improvements at any time. Specifications and design are subject to change without notice. Safety Notices As you work on Manitowoc equipment, be sure to pay close attention to the safety notices in this manual. Disregarding the notices may lead to serious injury and/ or damage to the equipment.
Table of Contents (continued) Part Number 020001552 5/11 i Section 1 General Information Read This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Unit Inspection . . . . . . . . . . . . . .
Table of Contents (continued) ii Part Number 020001552 5/11 Refrigeration Unit Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12 Positioning of Refrigeration Unit . . . . . . . . . . . . . . . . . . . . . .
Table of Contents (continued) Part Number 020001552 5/11 iii Section 4 Maintenance Sanitizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Beverage System Cleaning . . . . . . . . .
Table of Contents (continued) iv Part Number 020001552 5/11 THIS PAGE INTENTIONALLY LEFT BLANK.
Section 1 General Information Part Number 020001552 5/11 1-1 Section 1 General Information Read This Manual Manitowoc Food Service developed this manual as a reference guide for the owner/operator and installer of this equipment. Please read this manual before installation or operation of the machine.
General Information Section 1 1-2 Part Number 020001552 5/11 Accessories Depending on store type and location, various optional equipment (such as CO 2 Panel, water filter kit, water booster kit, etc.
Section 1 General Information Part Number 020001552 5/11 1-3 Serial Plate Location Warranty Information Consult your local MBE Distributor for terms and conditions of your warranty. Your warranty specifically excludes all beverage valve brixing, general adjustments, cleaning, accessories and related servicing.
General Information Section 1 1-4 Part Number 020001552 5/11 THIS PAGE INTENTIONALLY LEFT BLANK.
Part Number 020001552 5/11 2-1 Section 2 Installation General UNPACKING AND INSPECTING Carefully inspect the refrigeration unit immediately upon unpacking. Verify the equipment and parts received against the Bill of Lading. Locate all items according to packing list and inspect for possible damage caused by shipping.
Installation Section 2 2-2 Part Number 020001552 5/11 Dimensions and Clearances • Refrigeration units require stand or 6" (15.2 cm) legs. Refrigeration unit cannot be placed directly on floor. • Conduit can be run through floor or ceiling chase.
Section 2 Installation Part Number 020001552 5/11 2-3 REMOTE CONDENSER BLADE TOWER OPTIONAL 38.00" (96.52 cm) 34.00" (86.36 cm) 30.00" (76.20 cm) 29.50" (74.93 cm) 29.16" (74.06 cm) 6.00" (15.24 cm) 3.50" (8.89 cm) 4.
Installation Section 2 2-4 Part Number 020001552 5/11 Safe Installation Dos and Don’ts • DO adhere to all National and Local Plumbing and Electrical Safety Codes. • DO turn OFF incoming electrical service switches when servicing, installing, or repairing equipment.
Section 2 Installation Part Number 020001552 5/11 2-5 Location Requirements CLEARANCES RATINGS Select a location for the refrigeration unit that meets the requirements of the building plans, local codes, and personnel. The unit must be positioned for free airflow as well as for future service.
Installation Section 2 2-6 Part Number 020001552 5/11 Installer Instructions These equipment instructions are intended to assist qualified personnel in the unpacking, locating and the initial operation of the Multiplex Beverage Equipment Post Mix Refrigeration Unit.
Section 2 Installation Part Number 020001552 5/11 2-7 GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock.
Installation Section 2 2-8 Part Number 020001552 5/11 Plumbing/Water Supply PLUMBING POTABLE WATER A 1" (2.54 cm) ID copper inlet water line equipped with a 3/4" (1.905 cm) FPT sweat adapter with shut-off must be supplied by plumber at rear of equipment.
Section 2 Installation Part Number 020001552 5/11 2-9 PLUMBING CIRCUIT DIAGRAMS — MODEL 11M ROOT BEER Single Tower Plumbing Installation Kit (020001441) 020001403 00861302 Pressurized Filtered Water.
Installation Section 2 2-10 Part Number 020001552 5/11 Model 11M Root Beer Dual Tower Plumbing Installation Kit (020001441) 020001403 00861302 Pressurized Filtered Water Supply Primary Carb Pump Circ .
Section 2 Installation Part Number 020001552 5/11 2-11 Model 11M Root Beer Three Tower Plumbing Installation Kit (020001441) 020001403 00861302 Pressurized Filtered Water Supply Primary Carb Pump Circ.
Installation Section 2 2-12 Part Number 020001552 5/11 Refrigeration Unit Installation POSITIONING OF REFRIGERATION UNIT Before proceeding with installation, verify that all requirements for roof mounted Remote Condenser Units have been satisfied (if applicable).
Section 2 Installation Part Number 020001552 5/11 2-13 2. Connect the circulating water by connecting one line to the circulating pump outlet line (3/8” barb) and clamp in place. Connect the other line to the bulkhead return fitting located by the agitator motor (3/8” barb) and clamp in place.
Installation Section 2 2-14 Part Number 020001552 5/11 Connect the drain Locate the drain hose, bracket and the two (2) screws provided in the installation kit. Attach the drain hose to the water bath overflow tube located on the bottom of the refrigeration unit.
Section 2 Installation Part Number 020001552 5/11 2-15 Model 11M Connections John Guest Fittings Drain Hose Control Switches Opening for Conduit Supply Lines.
Installation Section 2 2-16 Part Number 020001552 5/11 INSULATING CONNECTIONS 1. Make sure all exposed carbonated water and syrup lines are well insulated on towers to conduit, conduit junctions, refrigeration unit to conduits, and drivethrough junction.
Section 2 Installation Part Number 020001552 5/11 2-17 PRE-CHARGED REFRIGERATION LINE REQUIREMENTS 1. Both the discharge and liquid remote condensing lines must be kept to a minimum distance for maximum performance. All Multiplex systems are capacity rated to 100 ft (30.
Installation Section 2 2-18 Part Number 020001552 5/11 CONNECTING THE PRE-CHARGED REFRIGERATION LINES NOTE: Before connecting the pre-charged refrigeration lines, the refrigeration unit must be properly located, leveled, and the water bath filled 1" (2.
Section 2 Installation Part Number 020001552 5/11 2-19 Start-Up 1. Turn on main water supply, set incoming regulator to 25 PSI (must be lower than CO 2 supply pressure). Once water is supplied to the unit air needs to be purged from the carbonator tank.
Installation Section 2 2-20 Part Number 020001552 5/11 Installation Checklist Check all fittings and conduit attachments for leaks. Check all insulated connections to make sure that they are sealed. Observe the pump operations for leaks. Check the water bath for full ice bank.
Section 3 Operation Part Number 020001552 5/11 3-1 Section 3 Operation Typical System Multiplex Pre-mix Beverage System Operation and Layout Conduit (In Wall) 6 Valve Soda Tower 8 Valve Soda Tower Wat.
Operation Section 3 3-2 Part Number 020001552 5/11 How the Multiplex Works The Model 11M is a 1/2 HP refrigeration unit that will provide premix carbonated beverages and chilled carbonated water for up to 12 gal (45 L) of syrup/day or 560 drinks/day (4,000 gal/year) with a 100 ft (30 m) maximum conduit length.
Section 3 Operation Part Number 020001552 5/11 3-3 Start-up PLACING EQUIPMENT IN OPERATION Before placing equipment in operation, verify that all requirements for roof mounted Remote Condenser Units (if applicable) have been satisfied. Refer to the instructions on installing the Remote Condenser.
Operation Section 3 3-4 Part Number 020001552 5/11 THIS PAGE INTENTIONALLY LEFT BLANK.
Section 4 Maintenance Part Number 020001552 5/11 4-1 Section 4 Maintenance Sanitizing BEVERAGE SYSTEM CLEANING Sanitize the beverage system at initial start-up as well as regularly scheduled cleaning. The drain pan must be in place under soda valves, to carry away detergent and sanitizing agents that will be flushed through valves.
Maintenance Section 4 4-2 Part Number 020001552 5/11 5. Draw rinse water through system until clean water is dispensed. Most beverage valves allow the syrup side to be manually activated by depressing the syrup pallet. 6. Connect Bucket 2 to system. 7.
Section 4 Maintenance Part Number 020001552 5/11 4-3 Back-flow Preventer Maintenance The integral carbonator in this unit is equipped with a back-flow preventer designed to protect the potable water supply from CO 2 contamination. 1. Shut OFF power to unit.
Maintenance Section 4 4-4 Part Number 020001552 5/11 THIS PAGE INTENTIONALLY LEFT BLANK.
Section 5 Before Calling for Service Part Number 020001552 5/11 5-1 Section 5 Before Calling for Service Checklist If a problem arises during operation of your post mix soda refrigeration unit, follow the checklist below before calling service. Routine adjustments and maintenance procedures are not covered by the warranty.
Before Calling for Service Section 5 5-2 Part Number 020001552 5/11 THIS PAGE INTENTIONALLY LEFT BLANK.
.
Manitowoc Beverage Systems 2100 Future Drive Sellersburg, IN 47172, USA Ph: 812-246-7000 Fax: 812-246-7024 Visit us online at: www.manitowocfsg.com © 2011 Manitowoc Continuing product improvements may necessitate change of specifications without notice.
デバイスManitowoc Ice 11Mの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Manitowoc Ice 11Mをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはManitowoc Ice 11Mの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Manitowoc Ice 11Mの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Manitowoc Ice 11Mで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Manitowoc Ice 11Mを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はManitowoc Ice 11Mの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Manitowoc Ice 11Mに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちManitowoc Ice 11Mデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。