MANLEY LABORA TORIES, INC. OWNER'S MANUAL LANGEVIN DUAL V OCAL COMBO MANUFACTURED BY: MANLEY LABORATORIES, INC. 13880 MAGNOLIA AVE. CHINO, CA. 91710 USA TEL: (909) 627-4256 FAX: (909) 628-2482 email:emanley@manleylabs.
CONTENTS INTRODUCTION 3 FRONT PANEL 4, 5 BACK PANEL 6 MIC PRE BASICS 7 CONNECTING YOUR PREAMPLIFIER 8, 9 OPERATION NOTES 10, 11 SPECIFICATIONS 12 TROUBLESHOOTING 13, 14 INTERNAL ADJUSTMENTS 15 REPLACI.
INTRODUCTION THANK YOU!... for choosing the Langevin Dual Vocal Combo. Manley Labs bought all the rights to the Langevin name and circuits in 1992. Manley uses the Langevin name for its solid state products including versions of an all discrete Pultec and Electro-Optical Limiter, and Mic Preamp.
4 OFF OFF POWER POWER ON ON IN IN BYPASS BYPASS INPUT INPUT H.F. H.F. L.F. L.F. 12 KHz 12 KHz EQ IN EQ IN 80 80 Hz Hz 80 80 Hz Hz EQ IN EQ IN 12 KHz 12 KHz L.
J) DIRECT INPUT. This is for plugging in an electric guitar, bass, synth, etc into the Dual Vocal Combo. The input impedance is high (150 kOhms) appropriate for these instruments and there should be plenty of gain available. Electric guitars and basses may need a fair amount of H.
LINE OUT LINE OUT BALANCED BALANCED email: emanley@manleylabs.com email: emanley@manleylabs.com PHONE (909) 627-4256 PHONE (909) 627-4256 FAX FAX (909) 628-2482 (909) 628-2482 13880 MAGNOLIA AVE.
MIC PRE BASICS 7 This Microphone Preamp, like most mic preamps, is pretty easy to use. First we can discuss why outboard mic pre's have become "a must have item" in almost every studio .
CONNECTING YOUR PREAMPLIFIER 8 Easy - Connect the mic to the Microphone Input XLR, then connect the Line Output to your tape machine or console. Read on, there are some things to consider. On the back panel are female XLR's labelled MIC INPUT A and MIC INPUT B.
9 Reversing the polarity or phase is often needed when two or more mics are picking up the same source. For example it would be needed when one mics the top and bottom of a snare - one skin is going towards one mic and the other skin is going away from the other mic.
OPERA TION NOTES The Langevin Electo-Optical Limiter follows certain traits and traditions established by the UREI LA-3A and similar levelling amplifiers. These traits can be divided into two aspects - electronic and operation. The electronic concept is simple and rather clean.
The slope or ratio is also difficult to simulate. The initial ratio is low and becomes higher with more gain reduction until the leds light up fully and further reduction is not easy.
SPECIFICA TIONS 12 Frequency Response 20 Hz to 20 KHz (+/- 1 dB) Mic Pre 20 Hz to 50 KHz (+/- .5 dB) Limiter THD & Noise .075% (1Khz @ +4 dBm) Mic Pre .
TROUBLE-SHOOTING There are a number of possible symptoms of something not quite right, some may be interfacing, others we will touch on as well. The Dual Vocal Combo has a variety of balanced and unbalanced inputs and outputs optimised for typical standards and most problems are due to the right cable in the wrong jack.
HUM - Let's assume it knows the words. Once again - several possibilities - several cures. Most likely it is a ground loop. The two most common procedures are: try a 3 pin to 2 pin AC adapter (about a dollar at the hardware store) which is better than messing up the power cable by bending the ground pin until it breaks off.
INTERNAL ADJUSTMENTS 1 7 4 5 9 10 6 8 3 1) +36 Volt DC adjust with meter from ground to resistor marked by arrow. Check this first and adjust if needed. It is the power supply regulator adjustment. Now for the audio .... You will have to start out by setting front panel controls to these settings.
REPLACING FUSES & METER LAMPS Changing the fuse is easy and can be done without any tools and while the DVC is still in a rack. 1) Disconnect the IEC AC mains for safety 2) Rotate the fuse cap ant.
MAINS CONNECTIONS Your unit has been factory set to the correct mains voltage for your country. The voltage setting is marked on the serial badge, located on the rear panel. Check that this complies with your local supply. The voltage changeover switch is located inside the unit in the middle of the PCB near the power transformer.
W ARRANTY All Manley Laboratories equipment is covered by a limited warranty against defects in materials and workmanship for a period of 90 days from date of purchase to the original purchaser only.
W ARRANTY REGISTRA TION We ask that you please fill out this registration form and mail the bottom half to: MANLEY LABORATORIES REGISTRATION DEPARTMENT 13880 MAGNOLIA AVE. CHINO CA, 91710 or FAX to: (909) 628-2482 or email service@manleylabs.com with the info from below and a note that this is for warranty registration.
OFF OFF POWER POWER ON ON IN IN BYPASS BYPASS INPUT INPUT H.F. H.F. L.F. L.F. 12 KHz 12 KHz EQ IN EQ IN 80 80 Hz Hz 80 80 Hz Hz EQ IN EQ IN 12 KHz 12 KHz L.
デバイスManley Labs Langevin Dual Vocal Comboの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Manley Labs Langevin Dual Vocal Comboをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはManley Labs Langevin Dual Vocal Comboの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Manley Labs Langevin Dual Vocal Comboの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Manley Labs Langevin Dual Vocal Comboで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Manley Labs Langevin Dual Vocal Comboを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はManley Labs Langevin Dual Vocal Comboの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Manley Labs Langevin Dual Vocal Comboに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちManley Labs Langevin Dual Vocal Comboデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。