Heater Size: 150,000 Btu/Hr Model: BR150CE IMPORTANT Read and understand this manual before assembling, starting or servicing heater. Improper use of heater can cause serious injury.
2 102384 Safety Information ................................................................................ 2 Product Identification ........................................................................... 4 Unpacking ............................
3 102384 SAFETY INFORMA TION Continued W ARNINGS (Continued) • Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.
4 102384 PRODUCT IDENTIFICA TION Side Cover Lower Shell Fuel Cap Hot Air Outlet Upper Shell Flame-Out Control Reset Button Power Cord Figure 1 - 150,000 Btu/Hr Fuel Tank Fan Guard Figure 2 - 150,000 B.
5 102384 UNP ACKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater. ASSEMBL Y These models are furnished with wheels and handles.
6 102384 THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber.
7 102384 VENTILA TION Provide a fresh air opening of at least 2800 square cm (three square feet) for each 100,000 Btu/Hr rating. Provide extra fresh air if more heaters are being used. Example: A 150,000 Btu/Hr heater will require at least 4,200 square cm (4.
8 102384 OPERA TION Continued To Stop Heater 1. Unplug power cord from outlet. To Restart Heater 1. Wait 2 minutes after stopping heater. 2. Repeat steps under To Start Heater , page 7. ST ORING, TRANSPORTING, OR SHIPPING Note: If shipping, transport companies require fuel tanks to be empty.
9 102384 TROUBLE- SHOOTING Wrong pump pressure Dirty air output, air intake, and lint filters Dirty fuel filter Dirt in nozzle Dirty photocell lens Bad flame-out control See Pump Pressure Adjustment , page 12. See Air Output, Air Intake and Lint Filters , page 12.
10 102384 SER VICE PROCEDURES Upper Shell Removal 1. Remove screws and lock washers along each side of heater using 5/16" nut- driver. These screws attach upper and lower shells together. 2. Lift upper shell off. 3. Remove fan guard. W ARNING Never service heater while it is plugged in, operating, or hot.
11 102384 Spark Plug 1. Remove upper shell (see page 10). 2. Remove fan (see page 15). 3. Remove spark plug wire from spark plug. 4. Remove spark plug from burner head using 13/16" open-end wrench. 5. Clean and regap spark plug electrodes as follows: 2.
12 102384 Air Output, Air Intake, and Lint Filters 1. Remove upper shell (see page 10). 2. Remove filter end cover screws using 5/16" nut- driver. 3. Remove filter end cover. 4. Replace air output and lint filters. 5. Wash or replace air intake filter (see Preventative Maintenance Schedule, page 8).
13 102384 Nozzle 1. Remove upper shell (see page 10). 2. Remove fan (see page 15). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench. 6.
14 102384 Pump Rotor (Procedure if rotor is binding) 1. Remove upper shell (see page 10). 2. Remove filter end cover screws using 5/16" nut- driver. 3. Remove filter end cover and air filters. 4. Remove pump plate screws using 5/16" nut- driver.
15 102384 Fan IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch. 1. Remove upper shell (see page 10). 2. Use 1/8" allen wrench to loosen setscrew which holds fan to motor shaft.
16 102384 ILLUSTRA TED P ARTS BREAKDOWN 150,000 Btu/Hr Model 13-1 13-2 13-3 13-4 13-5 13-6 13-7 13-8 13-13 13-15 13-16 13-17 13-18 13-14 Motor and Pump Assembly Burner Head Assembly 8-1 8-2 8-4 8-3 8-.
17 102384 P ARTS LIST 150,000 Btu/Hr Model This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part.
18 102384 WHEELS AND HANDLES 1 2 3 5 6 4 7 KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 HA2204 Handles 2 2 M12345-33 Screw, #10-24 x 1 3/4" 8 3 M12831-3 Wheel Support Frame 1 4 NTC-3C Hex Nut, #10.
19 102384 WIRING DIAGRAMS EC CONFORMITY DECLARA TION EC CONFORMITY DECLARA TION DESA Europe B.V . Industrieweg 167, 3044 AS Postbus 1 1 158 3004 ED Rotterdam Holland Manufacturer: DESA International, Inc. 2701 Industrial Drive Bowling Green, KY 42101 U.
20 102384 W ARRANTY AND REP AIR SER VICE POSE. IN ANY EVENT IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PAR- TICULAR PURPOSE ARE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. Any transportation charges, costs of installation, duty, taxes or any other charges whatsoever must be borne by the user.
デバイスMaster Lock BR150CEの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Master Lock BR150CEをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMaster Lock BR150CEの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Master Lock BR150CEの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Master Lock BR150CEで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Master Lock BR150CEを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMaster Lock BR150CEの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Master Lock BR150CEに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMaster Lock BR150CEデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。