MaxTechメーカー28の使用説明書/サービス説明書
ページ先へ移動 of 20
User's Manual Contents Section One Introduction ............................ 1 Section Two Installation .............................. 1 Section Three AT Command Set ................... 6 Section Four S Register Summary ............ 11 Section Five Result Codes .
1 Section One - Introduction The 28.8 Kbps Series FAX/Data Modem products connect your computer to all popular high speed modems available today. The modem supports the V.34 protocol to supply the highest speed connections possible. It also uses V.42 or MNP 2-4 error correction for flawless connections and V.
2 set to COM1 on IRQ4. Reconfigure the modem to either COM3/IRQ5 or COM4/IRQ2 (refer to Table 2-1 in Sec- tion 2.4). 4. Remove your computer's cover (refer to your computer's owner manual). 5. Select any available half-card slot, and then remove the slot cover (refer to Figure 2-2).
3 Panel, double-click on Ports . Click once on the icon for the Com port you have set your modem to. Click the Settings button. Click the Advanced button. The Base I/O Port Address should already be set by Windows to the COM port address used by the modem (refer to Table 2-1).
4 An IRQ (interrupt request) is a signal generated by an I/O device that notifies the computer of incoming data. Your internal modem is capable of accessing IRQs 2, 3, 4, and 5. I/O devices in your computer cannot share an IRQ with another device at the same time.
5 2. 5 Using the Fax Capabilities of the Modem Your modem has built-in advanced FAX functions. The commands to control these functions are software driven and are not normally accessible to the user. Consult your FAX software manual about procedures on using FAX features.
6 commonly asked questions and problems. Section Three - AT Command Set 3. 1 Executing Commands Commands are accepted by the modem while it is in Command Mode. Your modem is automatically in Com- mand Mode until you dial a number and establish a connec- tion.
7 B6 2400 bps connection only B7 4800 bps connection only B8 9600 bps connection only B9 14400 bps connection only B10 16800 bps connection only B11 19200 bps connection only B12 21600 bps connection .
8 O1 Return to Data Mode and initiate an equalizer retrain O2 Same as O1 with speed fall forward O3 Same as O1 with speed fall backward P Set Pulse dial as default Q0 Modem sends responses Q1 Modem does not send responses Sr? Read and display value in register r.
9 with &D0) &F 4 Same as &F2 except for Macintosh computers (&F2 with &D0) &F 5 Same as &F except V.42bis and flow control are disabled &G 0 Guard tone disabled &G1.
10 %L n Set transmit level to - n dBm Default = 12. (n =0-15) %M 0 Autodetect V.34 and V.FC negotiation signals %M1 Autodetect V.34 negotiation signals only %M2 Autodetect V.
11 Kn Set break control (n= 0-5). Default is 5 N0 Normal data-link only N1 Direct data-link only N2 MNP data link only N3 MNP or Normal data link N4 V.
12 Table 4-1 S - Registers Register Function Range/units Default S0 Auto-answer Ring 0-255/rings 0 S1 Ring counter 0-255/rings 0 S2 Escape code character 0-127/ASCII 43 S3 Carriage return character 0-.
13 CONNECT 9600 13 CONNECT 12000 14 CONNECT 14400 15 CONNECT 16800 60 CONNECT 19200 61 CONNECT 21600 62 CONNECT 24000 63 CONNECT 26400 64 CONNECT 28800 65 CONNECT 38400 66 CONNECT 57600 67 CONNECT 115.
14 CONNECT 300/V42 32 CONNECT 1200/V42 33 CONNECT 2400/V42 34 CONNECT 4800/V42 35 CONNECT 7200/V42 36 CONNECT 9600/V42 37 CONNECT 12000/V42 38 CONNECT 14400/V42 39 CONNECT 16800/V42 90 CONNECT 19200/V.
15 Section Six - Troubleshooting This section describes some of the common problems you may encounter while using your modem. If you can not resolve your difficulty after reading this chapter, contact your dealer or vendor for assistance. Modem does not respond to commands.
16 sounds noisy, you may have difficulty connecting to the remote device. Modem makes a connection but no data appears on your screen. 1. The remote system may be waiting to receive your data before it begins. Try pressing the ENTER key a few times. 2.
17 Section Seven - Specifications Communication Std. V.34, V.FC, V.32bis, V.32, V.29, V.27ter, V.22bis, V.23, V.22, V.21, V.17, Bell212/ 103 Data Compression: V.
18 operation of your equipment. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service. The FCC prohibits this equipment to be connected to party lines or coin-telephone service.
19 Before installing this equipment, users ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an accept- able method of connection.
デバイスMaxTech 28の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
MaxTech 28をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMaxTech 28の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。MaxTech 28の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。MaxTech 28で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
MaxTech 28を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMaxTech 28の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、MaxTech 28に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMaxTech 28デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。