Part #MAN128 Rev. 1.0 K56Plus-L/CPI-SVD High Performance K56Plus/V .34+/V .42bis 56K BPS Plug & Play Internal V oice/F AX/Data/SVD Modem With Advanced Speakerphone functions User's Manual Contents Section One - Introduction ..................
The information contained in this manual has been validated at the time of this manual's production. The manufacturer reserves the right to make any changes and improvements in the product de- scribed in this manual at any time and without notice.
1 Section One - Introduction This 56 Kbps* Plug and Play FAX/Voice/Data/ SVD Speakerphone Modem connects your computer to all popular high speed modems available today. The modem incorporates “K56Plus” (56Kbps) technology to provide increased download speeds using regular telephone lines.
2 (e.g., Windows 95), or B) A Plug and Play Revision 1.0a compliant PC. Proceed to Section 2.3 now if you have every- thing required. If you have neither 2A or 2B above, youneed to install Windows 95 to provide Plug and Play function- ality to your PC.
3 7. Connect the telephone cable from the modem's LINE connector to the telephone wall jack. 8. Optionally, connect your telephone to the modem's PHONE connector.
4 2.4.1.1 Windows 95 Release 4.00.950 When Windows 95 starts for the first time after card installation, it detects the modem and displays the New Hardware Found dialog box. Under New Hardware Found , when asked to “Select which driver you want to install for your new hardware,” click on “Driver from disk provided by hardware manufacturer.
5 2.4.2 Configuring in a Plug and Play System with- out Windows 95 When this modem is installed in a Plug and Play system without Windows 95, the computer's BIOS will assign a COM port and IRQ line to the modem. Proceed to Section 2.5, Software Installation/ Configuration.
6 RJ-11 jack marked “PHONE” or by attaching a micro- phone to the MIC jack and a speaker to the SPK jack of your sound card. Follow instructions in the FAX/ Voice/Speakerphone software on recording and play- back of voice prompts.
7 are interested in accessing the modem manually, and not through the included software. Section 4 and 5 contain reference material, and can be skipped. If you have difficulties getting your modem to work, read Section 6 - Troubleshooting to find answers to com- monly asked questions and problems.
8 B1 Bell mode B2 V.23 originate mode @ 75 bps transmit/ 1200 bps receive B 3 V.23 originate mode @ 1200 bps transmit/75 bps receive B15 Selects V.21 at 300 bps B16 Selects Bell 103 at 300 bps D _ 0 -.
9 O _ O0 Return to Data Mode O1 Return to Data Mode and initiate an equalizer retrain P Set Pulse dial as default Q_ Q0 Modem sends responses Q1 Modem does not send responses Sr? Read and display value in register r. Sr=n Set register r to value n (n = 0-255).
10 DTR toggle &D 2 Modem hangs up, returns to the Command Mode after DTR toggle &D3 Resets modem after DTR toggle &F_ &F Recall factory default configuration &G_ &G0 Guard tone.
11 compression %C1 Enable MNP Class 5 data compression only &Q_ &Q0 Direct data link only (same as N1) &Q5 V.42 data link with fallback options &Q6 Normal data link only (same as N0) A.
12 pass XON/XOFF to remote modem or local DTE -C_ -C0 Data calling tone disabled -C1 Data calling tone enabled 3.6 Fax Class 1 Commands +FCLASS? Service class indication +FCLASS=? Service class capabi.
13 +FDTC: Report the polled station capabilities +FET: Post Page Message Response +FET=n Transmit Page Punctuation +FHNG Call Terminations with Status +FK Session Termination +FLID= Local ID String +F.
14 -SRM Retrieve message -SSE=n n=0 Disable DSVD n=1 Enable DSVD -SSP Set transmission speeds -SSR Start sequence response control -SSV Data mode event message -STM Time -STT Telephone handset transaction tone control -SVV Start Voice View data mode Section Four - S Registers Your modem has 28 registers, designated S0 through S92.
15 S37 Connection speed 0-19 0 S38 56K dial line rate 0-16 1 S42-43 Reserved S48 LAPM negotiation 7, 128 7 S89 Sleep mode timer 0, 5-255 seconds 10 S90 Local phone status 0=on hook, 1=off hook S92 Tra.
16 t o “ t a l k ” t o t h e m o d e m o n t h e c o r r e c t C O M p o r t a n d I R Q s e t t i n g ( s a m e C O M p o r t a n d I R Q s e t t i n g a s t h e m o d e m ) .
17 C O M p o r t s :1 , 2 , 3 , 4 IRQ lines: 3, 4, 5, 7, 9, 10, 11, 12, 15 FAX Group: Group III Send/Receive Standard FAX Command set: EIA/TIA-578 Service Class 1, EIA/TIA-SP2388 Service Class 2 Transmit level: -11 dBm +/- 1 dB Receiver Sensitivity: -39 dBm (V.
18 T h e F C C a l s o r e q u i r e s t h e t r a n s m i t t e r o f a F A X t r a n s m i s s i o n b e p r o p e r l y i d e n t i f i e d ( p e r F C C R u l e s P a r t 6 8 , S e c .
19 N O T I C E : T h e L o a d N u m b e r ( L N ) a s s i g n e d t o e a c h t e r m i n a l d e v i c e d e n o t e s t h e p e r c e n t a g e o f t h e t o t a l l o a d t o b e c o n n e c t e d t o a t e l e p h o n e l o o p w h i c h i s u s e d b y t h e d e v i c e , t o p r e v e n t o v e r l o a d i n g .
20.
21.
デバイスMaxTech Plug & Play Internal Voice/FAX/Data/SVD Modemの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
MaxTech Plug & Play Internal Voice/FAX/Data/SVD Modemをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMaxTech Plug & Play Internal Voice/FAX/Data/SVD Modemの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。MaxTech Plug & Play Internal Voice/FAX/Data/SVD Modemの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。MaxTech Plug & Play Internal Voice/FAX/Data/SVD Modemで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
MaxTech Plug & Play Internal Voice/FAX/Data/SVD Modemを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMaxTech Plug & Play Internal Voice/FAX/Data/SVD Modemの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、MaxTech Plug & Play Internal Voice/FAX/Data/SVD Modemに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMaxTech Plug & Play Internal Voice/FAX/Data/SVD Modemデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。