MaxtorメーカーELX16-240の使用説明書/サービス説明書
ページ先へ移動 of 72
ELX16 - 240 Installation Guide (v 1.0).
FCC Compliance Statement Caution : Any changes or modifications in construction of this device which are not expr essly approved the party responsible for compliance could void the user's authority to operate the equipment.
Important Notice 1. D o not p lace heavy objects on the top of the ELX16 - 240 . 2. ELX16 - 240 is for indoor use. It is not weatherproof. Use ELX16 - 240 with referring to its environmental specifications (Temp erature & Humidity). To clean the ELX16 - 240 , gently wipe the outside with a clean dry cloth.
ELX16 - 240 Contents 4 Error! Unknown document property name. (v 1.0) Rugged CCTV Contents OVERVIEW .......................................................................................................................................................
Contents ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 5 8.2.7. Apply Date/Time ................................................................................................ ....................... 22 8.3. Setting Recording Condition .
ELX16 - 240 Contents 6 Error! Unknown document property name. (v 1.0) Rugged CCTV 11. Network Monitoring & Managing ................................................................................................ ...... 42 11.1. Connecting Ethernet .
OVERVIEW ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 7 OVERVIEW 1. What i s ELX16 - 240 ? The ELX16 - 240 is an 16 - a nalog channel s network digital video recorder. Video, Audio, and Text Event - Logs are digitized and stored on two internal hard - drives.
ELX16 - 240 OVERVIEW 8 Error! Unknown document property name. (v 1.0) Rugged CCTV 2. Supplied Accessories Unpack and check all the items as below. 1. ELX16 - 240 (1EA) 2. AC Power Cord (1EA) 3. CD - ROM (Including DVR manager) (1EA) 4. Remote Controller (1EA) 5.
OVERVIEW ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 9 9. HDD DATA CABLE (1EA) 3. Description & Function ELX16 - 240 Front (1) Power switch (2) Function buttons (3) LED .
ELX16 - 240 OVERVIEW 10 Error! Unknown document property name. (v 1.0) Rugged CCTV ELX16 - 240 Rear (8) BNC connector for video input (9) AC power connector (10) BNC connector for video output (11) BN.
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 11 INSTALLATION AND CONNECTION 4. Connecting & Running 4.1. Connecting camera (1) Connect CCTV camera to ELX16 - 240 with BNC cable as shown below .
ELX16 - 240 INSTALLATION AND CONNECTION 12 Error! Unknown document property name. (v 1.0) Rugged CCTV 4.2. Connecting Monitor (1) Connec t CCTV monitor to ELX16 - 240 with BNC cable as shown below . ELX16 - 240 has two monitor output ports ; for A(Normal) and B(Spot) .
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 13 4.4. Supplying Power (1) Connect power cable . 1. When supplying power, ELX16 - 240 starts booting automatically. 2. When pressing the power switch during 5 seconds, a dialogue for entering admin password occurs.
ELX16 - 240 INSTALLATION AND CONNECTION 14 Error! Unknown document property name. (v 1.0) Rugged CCTV 5. Running OSD menu 5.1. Using menu P ress the [MENU] button to open the OSD Configuration Menu. (1) Main Menu T abs : The select ed tab is shown in blue and the related sub - menu s will be shown below the tab.
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 15 5.2. Dialogue Box t o Edit a Word There are two methods to set word. (1) Using number button Enter the related numbers in order of horizontal/vertical .
ELX16 - 240 INSTALL ATION AND CONNECTION 16 Error! Unknown document property name. (v 1.0) Rugged CCTV 6. Setting remote controller 6.1. Setting ID of ELX16 - 240 When controlling several DVR s with one remote controller, set Remote Control ID as follow s .
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 17 6.2. Selecting ELX16 - 240 If several DVR s are set with unique ID numbers, they can be controlled with one remote controller.
ELX16 - 240 INSTALLATION AND CONNECTION 18 Error! Unknown document property name. (v 1.0) Rugged CCTV 7. ELX16 - 240 Configuration 7.1. Basic Configuration 7.
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 19 7.3. External Storage & Backup Configuration 7.
ELX16 - 240 INSTALLATION AND CONNECTION 20 Error! Unknown document property name. (v 1.0) Rugged CCTV 8. ELX16 - 240 Basic Setting 8.1. Viewi ng Image After initial start - up, images are disp l ayed in multi - split screen according to the connected channels.
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 21 8.2. Setting Date & Time (1) Press [MENU] button, and select “ Quick Setup ” tab . (2) Select “ Date/Time ” and enter the Settings Page by pressing [ENTER].
ELX16 - 240 INSTALLATION AND CONNECTION 22 Error! Unknown document property name. (v 1.0) Rugged CCTV 8.2.4. Time Format (1) Select “ Time Format ” using the [ / ] or the [ / ] button s and press [EN TE R]. (2) Two Time Format s are available ; ‘ MM/DD/YYYY ’ and ‘ YYYY/MM/DD ’ .
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 23 8.3. Setting Recording Condition Recording condition s under the “ Quick Setup ” menu tab apply the same values to all analog channels 1~16.
ELX16 - 240 INSTALLATION AND CONNECTION 24 Error! Unknown document property name. (v 1.0) Rugged CCTV 8.3.2. Channel Status (1) Select “ Channel Status ” using [ / ] button s and press the [ENTER] button. (2) Select a value using the [ / ] button .
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 25 9. Connecting and Configuring DIO Ports Trimming Wire When connect ing a wire to a terminal block, follow the instructions below . Note the different types of wire that can be used.
ELX16 - 240 INSTALLATION AND CONNECTION 26 Error! Unknown document property name. (v 1.0) Rugged CCTV 9.1. Connecting and Configuring Sensor 9.1.1. Specification In order to run sensor input of ELX16 - 240 series normally, the following conditions are required.
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 27 9.1.3. Configuring Sensor at OSD menu (1) Press the [Menu] button, and select the “ Alar m Source ” among OSD menus. (2) Select “ Sensor ” menu and press the [ Enter] button for moving to the sub - menu.
ELX16 - 240 INSTALLATION AND CONNECTION 28 Error! Unknown document property name. (v 1.0) Rugged CCTV 1. This menu is to set sensor using and sensor type. However recording by sensor input and relay output should be set in another menu. 2. For recording setting by sensor input, refer to the “ Alarm Rec.
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 29 9.2. Connecting & Configuring Relay Out 9.2.1. Specification s In order to run relay output of ELX16 - 240 series normally, the following conditions are required .
ELX16 - 240 INSTALLATION AND CONNECTION 30 Error! Unknown document property name. (v 1.0) Rugged CCTV 9.2.3. Configuring Relay Out at OSD menu Relay can run by sensor or MD, and its condition can be set differently according to schedule.
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 31 9.3. Connecting Serial Port 9.3.1. Configuring Serial Ports for Pan/Tilt/Zoom The ELX16 - 240 series ha ve most major PTZ protocols a l re ady pre - programmed .
ELX16 - 240 INSTALLATION AND CONNECTION 32 Error! Unknown document property name. (v 1.0) Rugged CCTV 9.3.2. Diagrams of serial ports 9.3.2.1. Diagram of COM1 9.
INSTALLATION AND CO NNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 33 9.3.2.3. Diagram of COM3 9.3.2.4. Diagram of CO M4 9.
ELX16 - 240 INSTALLATION AND CONNECTION 34 Error! Unknown document property name. (v 1.0) Rugged CCTV 9.3.4. Configuring COM Port at OSD menu Configure PTZ COM ports and available modes at “ System / Serial Setup ” . After completing serial setup, configure base address and port for each channel under the “ Camera ” menu tab .
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 35 9.4. Connecting External Device with Serial Port 9.4.1. Connecting Text Input Device (ATM / POS / Access Control) In addition to images, the ELX16 - 240 can record text data received from POS/ATM through the COM1/RS232 serial port.
ELX16 - 240 INSTALLATION AND CONNECTION 36 Error! Unknown document property name. (v 1.0) Rugged CCTV 9.4.3. Configuring Text (1) Select the “ Alarm Source ” menu among OSD menus. (2) Select the “ Text ” , and set each value. Before installing any external device , consult with the local distributor.
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 37 9.5. Connecting USB Device USB port can be used to copy up to 1 minute of images to a USB F lash memory disk. When connecting USB device, do not exceed the rated values of USB device.
ELX16 - 240 INSTALLATION AND CONNECTION 38 Error! Unknown document property name. (v 1.0) Rugged CCTV 1. USB Flash product s that require a Windows program to operate may not be recognized by the DVR . 2. For more information about copy function, refer to the “ ELX16 - 240 User ’ s Guide ” .
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 39 10. Connecting External Storage 10.1. IEEE1394 Port ELX16 - 240 series have two IEEE1394 ports for external storage device interface. With them, ELX16 - 240 series can expand storage capacity up to 4TB.
ELX16 - 240 INSTALLATION AND CONNECTION 40 Error! Unknown document property name. (v 1.0) Rugged CCTV 10.3. Available HDD It is recommended to use the following HDD models with the ELX16 - 240 . If a non - recommended HDD is used , Rugged CCTV . will not guarantee the warranty.
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 41 (1) Press [ENTER] button at “ Select Disk ” . (2) Select new added HDD (indicated as “ [F] ” ) using [ / ] button and press [EXIT] button (3) Select “ Action ” using [ / ] button and press [EXIT] button.
ELX16 - 240 INSTALLAT ION AND CONNECTION 42 Error! Unknown document property name. (v 1.0) Rugged CCTV 11. Network Monitoring & Managing ELX16 - 240 can be accessed, controlled, and managed from remote site via Internet/Intranet. 11.1. Connecting Ethernet (1) Turn off ELX16 - 240 ’ s power switch.
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 43 11.2. Configuring ELX16 - 240 ’ s Network Information The following description is on based on Ethernet connection . For more detailed i nformation on the Network Settings Page , please refer to “ ELX16 - 240 OSD User ’ s Guide ” .
ELX16 - 240 INSTALLATION AND CONNECTION 44 Error! Unknown document property name. (v 1.0) Rugged CCTV 12. Using DVR manager 12.1. PC System Requirements for running DVR manager Minimal Requirements Re.
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 45 (4) Select which component s to install and press the “ Next ” button. (5) Browse and choose a directory if the default directory is no t preferred.
ELX16 - 240 INSTALLATION AND CONNECTION 46 Error! Unknown document property name. (v 1.0) Rugged CCTV 12.3. Uninstalling DVR manager (1) Click Windows “ Start ” Button. (2) Select and Click ‘ Uninstall ’ icon to run Uninstall Shield . (3) DVR manager p rogram w ill be automatically deleted.
INSTALLATION AND CONNECTION ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 47 12.5. Monitor Click the related icon and run the “ DVR ma nager Monitor ” program. 12.6. Playback Click the related icon and run the “ DVR manager Playback ” program.
ELX16 - 240 APPENDIX 48 Error! Unknown document property name. (v 1.0) Rugged CCTV APPENDIX APPENDIX.
APPENDIX ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 49 #1. HDD #1.1. Fundamental Notions & Terms DVR Storing Constructure (VFS2) DVR series has a peculiar storing constructu re, and its features are as follows.
ELX16 - 240 APPENDIX 50 Error! Unknown document property name. (v 1.0) Rugged CCTV Backup (1) Backup is possible only through IEEE1394 port, and HDD for backup should be formatted as FAT32 type. (Its type is indicated as [F] in Disk Manager.) Disk Manager (1) When HDD is added or deleted physically, Disk Manager runs automatically after rebooting.
APPENDIX ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 51 (3) HDD Managing Command Format Format as ELX16 - 240 ’ s file system. Not available to PC file system. Add Add HDD for recording. Need to format. Add Used Add a HDD that has been used and formatted.
ELX16 - 240 APPENDIX 52 Error! Unknown document property name. (v 1.0) Rugged CCTV Installing & Expanding Internal HDD Adding or replacing HDD should follow below process. (1) Turn off the power of ELX16 - 240 . (2) Check whether the dip switches are set as illustrated below.
APPENDIX ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 53 (4) Take out power and data cable of HDD from Main PCB ASS ’ Y. Remove 4 HDD Bracket screws and take out HDD ASS ’ Y. (5) Fix the HDD into HDD Bracket with provide d screws.
ELX16 - 240 APPENDIX 54 Error! Unknown document property name. (v 1.0) Rugged CCTV (6) Assemble cables according to the following numbers. The supplied HDD cables have two kinds of colors. When connecting to PCB Ass’ y, use blue cab le. (7) Fix the assembled HDD and earth cable into case with screws.
APPENDIX ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 55 When installing one primary disk (1) When power is supplied to ELX16 - 240 , “ Disk Manager ” runs automatically after rebooting. If not, run it manually in “ Menu à Utility à Disk Manager ” .
ELX16 - 240 APPENDIX 56 Error! Unknown document property name. (v 1.0) Rugged CCTV When installing one primary disk and auxiliary disk (1) When power is supplied to ELX16 - 240 , “ Disk Manager ” runs automatically after rebooting. If not, run it manually in “ Menu à Utility à Disk Manager ” .
APPENDIX ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 57 Expending External HDD (When using internal HDD as primary disk) ELX16 - 240 use IEEE1394 as external storage device interface, and has two ports of IEEE1394. ELX16 - 240 supports upto 4TB storage.
ELX16 - 240 APPENDIX 58 Error! Unknown document property name. (v 1.0) Rugged CCTV When using Disk Farm The following description is when ELX16 - 240 has internal primary disk and 3 sets of IEEE1394 HDD. (1) When external HDD farm is connected to IEEE1394 port, “ Disk Manager ” runs automat ically.
APPENDIX ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 59 When using RAID The following description is when ELX16 - 240 has internal primary disk and 1 set of IEEE1394 HDD. Even though several HDDs are connected to RAID, ELX16 - 240 will recognize them as only one HDD.
ELX16 - 240 APPENDIX 60 Error! Unknown document property name. (v 1.0) Rugged CCTV Installing & Expending External HDD (When using external HDD as primary disk) When using Disk Farm The following description is when ELX16 - 240 does ’ t have internal primary disk and 4 sets of IEEE1394 HDD.
APPENDIX ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 61 (8) Select a third HDD of [*] Ext . Press the “ Apply ” button after selecting action as “ Format ” . Then [*] is changed to [R]. (9) Select a fourth HDD of [*] Ext .
ELX16 - 240 APPENDIX 62 Error! Unknown document property name. (v 1.0) Rugged CCTV #1.3. Replacing HDD Checking HDD ELX16 - 240 file system (VFS2) sensors bad sector automatically, and the sensored bad sector is not used. The following means when HDD is broken or has some problem in connection.
APPENDIX ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 63 #1.4. Keeping Data To keep the stored data, you should back up or reserve as HDD itself. Backup (1) Connect backup HDD to IEEE1394 port. (2) Go to playback mode with pressing the [Playback] button.
ELX16 - 240 APPENDIX 64 Error! Unknown document property name. (v 1.0) Rugged CCTV How to preserve as HDD itself To keep HDD itself, it is possible only when HDD is installed and used in ELX16 - 240 (including primary disk and RAID ). And it is recommended to use external HDD instead of internal HDD.
APPENDIX ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 65 #2. How to Change Video Type In order to change video type of EL X16 - 240 series, jumper setting should be changed inside the case.
ELX16 - 240 APPENDIX 66 Error! Unknown document property name. (v 1.0) Rugged CCTV #3. Using CD - ROM Components of CD - ROM disc Installation Guide : ELX16 - 240 Installation Guide User ’ s Guide : ELX16 - 240 User ’ s Guide DVR manager : DVR manager User ’ s Guide ( ELX16 - 240 R emote Management Program) Acrobat Reader : Version 5.
APPENDIX ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 67 #4. Specification General CPU 32bit RISC Processor (200MIPS) Flash Memory 8MB Main Mem ory 64MB OS Embedded LINUX Video Channel 16 Analog Channel Storage Device Internal 3.
ELX16 - 240 APPENDIX 68 Error! Unknown document property name. (v 1.0) Rugged CCTV Display Monitoring Max. 120ips (60 for Monitor A, 60 for Monitor B) Viewer 1ch, 4ch, 9ch, 13ch, 16ch, Auto & Custum Sequence for Monitor A 1ch, Auto & Custume Sequce for Monitor B Playback Performance Max.
APPENDIX ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 69 PTZ Control Serial Port RS232(2),RS422/485(2) Control Method (Local) Front panel button & IR remote controller (c.
ELX16 - 240 APPEND IX 70 Error! Unknown document property name. (v 1.0) Rugged CCTV.
APPENDIX ELX16 - 240 Rugged CCTV Error! Unknown document property name. (v 1.0) 71.
Rugged CCTV . 5327 Cedar Creek Dr. Kemp, TX 75143 Tel : ( 866 ) 301 - 22 88 Fax : ( 903 ) 498 - 8 989 Technical Support: 1 - 866 - 301 - 2288 URL: www.
デバイスMaxtor ELX16-240の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Maxtor ELX16-240をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMaxtor ELX16-240の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Maxtor ELX16-240の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Maxtor ELX16-240で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Maxtor ELX16-240を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMaxtor ELX16-240の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Maxtor ELX16-240に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMaxtor ELX16-240デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。