MaytagメーカーHR650DJLSの使用説明書/サービス説明書
ページ先へ移動 of 36
FOR POT ABLE W A TER HEA TING ONL Y NOT SUIT ABLE FOR SP ACE HEA TING Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product.
2 W ARNING At the time of manufacture this water heater was provided with a combination temperature-pressures relief valve certified by a nationally recognized testing laboratory that maint ains perio.
CAUTION W A TER HEA TERS EVENTUALL Y LEAK: Installation of the water heater must be accomplished in such a manner that if the t ank or any connections should leak, the flow of water will not cause damage to the structure. For this reason, it is not advisable to inst all the water heater in an attic or upper floor .
4 Safety Instructions .....................................................................................................................2,3 T able of Content s ........................................................................................
5 Customer In formation Thank Y ou for purchasing a Maytag water heater . Properly installed and maint ained, it should give you years of trouble free service. It is strongly suggested that this new water heater be professionally installed, call Mayt ag Customer Service at1-800-788-8899 for recommended installers.
6 Product S pecifications *S tandard element wattages are shown. Other element watt ages (up to the maximum shown) are available when specified. *Wiring size based on standard 60°C copper wire. If dist ance from fuse box to water heater is more than 90 feet, refer to your local electrical code.
7 Product S pecifications *S tandard element wattages are shown. Other element watt ages (up to the maximum shown) are available when specified. *Wiring size based on standard 60°C copper wire. If dist ance from fuse box to water heater is more than 90 feet, refer to your local electrical code.
8 EXP ANSION T ANKS FOR THERMAL EXP ANSION CONDITIONS A V AILABLE IN 2 GALLON (P ART NUMBER 66001013) AND 5 GALLON (P ART NUMBER 66001014) CAP ACITY Accessories and T ools Needed Accessories T o simplify the installation Maytag has available the installation p arts shown below .
9 Inst allation Instructions Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors. Open the water heater drain valve. Open a nearby hot water faucet which will relieve pressure in the water heater and speed draining.
10 Locating The New W ater Heater Y ou should carefully choose an indoor location for the new water heater , because the placement is a very important consideration for the safety of the occup ants in the building and for the most economical use of the appliance.
11 TEMPERA TURE- PRESSURE RELIEF V AL VE COLD INLET W A TER LINE HOT OUTLET TO HOUSE THREADED TO SWEA T COUPLING 3/4” THREADED NIPPLE 3/4” THREADED NIPPLE FLOOR DRAIN DISCHARGE PIPE (Do not cap or.
COLD HOT 12 FLOOR DRAIN TEMPERA TURE- PRESSURE RELIEF V AL VE 6” AIR GAP DISCHARGE PIPE (Do not cap or plug) CONDUIT HOT COLD T emperature-Pressure Relief V alve Instructions for Inst allation (cont.
13 Instructions for Inst allation (cont’d) Filling the W ater Heater T o fill the water heater with water: 1. Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater .
Wiring 14 Instructions for Inst allation (cont’d) 1. Provide a way to easily shut off the electric power when working on the water heater . This could be with a circuit breaker or fuse block in the entrance box or a separate disconnect switch. 2. Install and connect a circuit directly from the main fuse or circuit breaker box.
MODEL RA TING PLA TE FLOOR DRAIN DISCHARGE PIPE (Do not cap or plug) 6” AIR GAP HOT 15 COLD TEMPERA TURE- PRESSURE RELIEF V AL VE CONDUIT HOT COLD Inst allation Checklist 1. Whether or not the element conversion is made, the model rating plate must be marked.
UPPER THERMOST A T ADJUST ABLE BEHIND UPPER ACCESS P ANEL LOWER THERMOST A T ADJUST ABLE BEHIND LOWER ACCESS P ANEL 16 Service and Maintenance The thermostat(s) of this water heater have been factory set at a position which approximates 120°F (HOT) to reduce the risk of scald injury .
2. T ake off the access panel, insulation block and p ad. 3. The slotted adjustment (using a screwdriver) can be turned clockwise ( ) to increase the temperature setting or counter clockwise ( ) to decrease the temperature setting. 4. Replace the insulation block, pad and access p anel.
18 Service and Maintenance (cont’d) Draining The water heater should be drained if being shut down during freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary . 1 . Before beginning turn “OFF” the electric power supply to the water heater .
19 Service and Maintenance (cont’d) 5. Remove the block of insulation and pad to expose the terminal cover . 3. Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors. Open the water heater drain valve. Open a nearby hot water faucet which will relieve pressure in the water heater and speed draining.
20 Service and Maintenance (cont’d) CAUTION Never use this water heater unless it is completely full of water . T o prevent damage to the tank and heating element, the t ank must be filled with water . Water must flow from the hot water faucet before turning “ON” power .
21 Drain V alve W asher Replacement NOTE: For replacement, use a 17/32”x 13/64”x 1/8” thick washer available at your nearest hardware store. For ordering a replacement washer , refer to the “Rep air Part s” section. 1 . Before beginning turn “OFF” the electrical power supply to the water heater .
22 S t art Up Conditions THERMAL EXP ANSION W ater supply systems may , because of such events as high line pressure, frequent cut-offs, the ef fects of water hammer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc.
23 5 . Replace the insulation block and pad so that it completely covers the thermostat and element. 6. Replace the access panel. 7. T urn “ON” electric power to the water heater .
T roubleshooting (cont’d) *NOTE: T o check where threaded portion enters t ank, insert cotton swab between jacket opening and fitting. If cotton is wet, follow “Draining” instructions in the “Service and Maintenance” section and then remove fitting.
Notes 25.
MA YT AG ELECTRIC W A TER HEA TERS MODEL NUMBERS HR630SJRT 30 GALLON HR630SJLS 30 GALLON HR640SJRT 40 GALLON HR640SJRS 40 GALLON HR640SJLS 40 GALLON 26 Rep air Part s List NOTE: LOWER ELEMENT : These water heaters have a 4500 watt lower element as st andard.
MODEL NUMBERS KEY P ART HR630SJRT HR630SJLS HR640SJRT HR640SJRS HR640SJLS NO. DESCRIPTION P ART NUMBERS 1 T emperature-Pressure Relief V alve 66001700 66001700 66001700 66001700 66001415 2 Dip T ube 6.
28 Rep air Part s List (cont’d) MA YT AG ELECTRIC W A TER HEA TERS MODEL NUMBERS HR652SJRT 50 GALLON HR650SJRS 50 GALLON HR650SJLS 50 GALLON HR666SJRT 66 GALLON HR682SJRT 80 GALLON HR6120SJRT 1 19 GALLON NOTE: LOWER ELEMENT : These water heaters have a 4500 watt lower element as st andard.
29 MODEL NUMBERS HR652SJRT HR650SJRS HR650SJLS HR666SJRT HR6120SJRT KEY P ART HR682SJRT NO. DESCRIPTION P ART NUMBERS 1 T emperature-Pressure Relief V alve 66001700 66001700 66001682 66001700 66001700.
2 3 4 5 6 6 7 9 10 8 12 11 14 21 20 20 22 13 1 30 Rep air Part s List (cont’d) MA YT AG ELECTRIC W A TER HEA TERS MODEL NUMBERS HR630DJRT 30 GALLON HR630DJLS 30 GALLON HR640DJRT 40 GALLON HR640DJRS 40 GALLON HR640DJLS 40 GALLON NOTE: LOWER ELEMENT and UPPER ELEMENT : These water heaters have 4500 watt lower and upper element s as standard.
MODEL NUMBERS HR630DJRT HR630DJLS HR640DJRT HR640DJRS HR640DJLS KEY P ART NO. DESCRIPTION P ART NUMBERS 1 T emperature-Pressure Relief V alve 66001700 66001700 66001700 66001700 66001682 2 Dip T ube 6.
32 Rep air Part s List (cont’d) MA YT AG ELECTRIC W A TER HEA TERS MODEL NUMBERS HR652DJRT 50 GALLON HR650DJRS 50 GALLON HR650DJLS 50 GALLON HR666DJRT 66 GALLON HR682DJRT 80 GALLON HR6120DJRT 1 19 GALLON NOTE: LOWER ELEMENT and UPPER ELEMENT : These water heaters have 4500 watt lower and upper element s as standard.
33 MODEL NUMBERS HR652DJRT HR650DJRS HR650DJLS HR666DJRT HR6120DJRT KEY P ART HR682DJRT NO. DESCRIPTION P ART NUMBERS 1 T emperature-Pressure Relief V alve 66001700 66001700 66001682 66001700 66001700.
34 Rep air Part s List (cont’d) MA YT AG/ST A TE P ART NUMBER CONVERSION KEY MA YT AG ST A TE 6600101 1 9001609 66001012 9001608 66001013 ETC2X 66001014 ETC5X 66001021 9001584 66001053 9000308 66001.
Notes 35.
W arranty FULL ONE YEAR W ARRANTY For One Y ear from the date of Original Retail Purchase, any part which fails in normal home use will be repaired or replaced free of charge. If a leak occurs in the T ank, a new water heater of the closest capacity and quality then available, will be replaced free of charge.
デバイスMaytag HR650DJLSの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Maytag HR650DJLSをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMaytag HR650DJLSの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Maytag HR650DJLSの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Maytag HR650DJLSで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Maytag HR650DJLSを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMaytag HR650DJLSの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Maytag HR650DJLSに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMaytag HR650DJLSデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。