Argosy ResearchメーカーH200 Seriesの使用説明書/サービス説明書
ページ先へ移動 of 13
H200 & H200HF SERIES W A TER CONDITIONERS Apartment Buildings Boiler W ater T reatment Car W ashes Commercial Buildings Condominiums Factories Hospitals Laundries Mobile Home Parks Motels and Hote.
Hellenbrand Means Quality and Reliability Since 1967, Hellenbrand, Inc. has provided water solutions to the water tr eatment industry in the U.S. and around the world.
• Solid state micropr ocessor can control fr om one to four units allowing you system add on capabilities as your needs grow . • Regeneration may be initiated with a time clock, meter delayed or meter immediate.
H200/H200HF Diagnostic and Histor y Screens provide the water treatment operator with a wealth of information. Diagnostic Screens • Days since last regeneration • T otal volume treated since last .
H200/H200HF Diagnostic and Histor y Screens provide the water treatment operator with a wealth of information. DIAGNOSTIC 5 DIAGNOSTIC 6 DIAGNOSTIC 7 DIAGNOSTIC 7-B WS2H Control V alve Manual Page 21 Diagnostic Screens (continued) DIAGNOSTICS 5 Maximum fl ow rate for the last 28 days.
H200/H200HF Diagnostic and Histor y Screens provide the water treatment operator with a wealth of information. HISTOR Y 1 HISTOR Y 2 HISTOR Y 3 Page 22 WS2H Control V alve Manual V alve History Returns to normal operation after 5 minutes.
Modes of Regeneration Time Clock - 7 or 28 day calendar clock shall initiate regeneration at a pr e-set time of day . Parallel Individual Meters - All units are in service at the same time with either delayed or immediate r e- generation. A lockout feature or of fsetting time of regeneration pr events more than one unit to r egenerate at a time.
A . MINERAL T ANK: Fiberglass tank with Polyethylene Inner Shell and Fiberglass Roving Manufactured to Operate at 150 psi. NSF Approved. B. DISTRIBUTOR SYSTEM: T wo-Inch Hub & Lateral Dis - tributor for Maximum Service Flow and Minimal Pressure Loss.
Brine T ank(s) Inlet Bypass V alve Brine T ank(s) Outlet Isolation V alves Flex Connectors MA V V alve H200 T win/T riple x/Fourple x Installation T op-Mount - First-in, Last-Out Piping Arrangement.
H200 T win Alternating - Side Mount H200 T win/T riple x/Fourple x Installation - Side Mount First-in, Last-Out Piping Arrangement. Brine T ank See NOTE Figure 7 Figure 6 Brine T ank(s) Figure 7 NOTE:.
H200 HF Single T ank Installation H200 HF T win Alternating Installation H200 HF T riple x/Fourple x Installation Brine T ank See NOTE Figure 7 Figure 8 See NOTE Figure 7 Figure 9 See NOTE Figure 7 Fi.
RECOMMENDED BRINE T ANK APPROXIMA TE PIPE SIZE MINERAL T ANK SIZE SAL T STORAGE SHIPPING WEIGHT -TOP MOUNT MODEL (INCHES) (INCHES) (INCHES) ( LBS) SINGLE TWIN H200-240 2 24 X 72 24 X 50 715 674 1325 H.
RA TED CAP ACITY FLOW RA TES (gpm) RESIN LOW SAL T MEDIUM SAL T HIGH SAL T BKW MODEL CU.FT . GRAINS/LBS GRAINS/LBS GRAINS/LBS 15 PSI 25 PSI GPM H200HF-300-24-3 10 190,000/60 280,000/100 320,000/150 12.
デバイスArgosy Research H200 Seriesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Argosy Research H200 Seriesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはArgosy Research H200 Seriesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Argosy Research H200 Seriesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Argosy Research H200 Seriesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Argosy Research H200 Seriesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はArgosy Research H200 Seriesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Argosy Research H200 Seriesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちArgosy Research H200 Seriesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。