Micro Technic A -S • Den mark • Tel. +45 66 15 3000 • Fax +45 6615 3077 E-mail: suppo rt@micro-technic.co m Website: www. micro-technic.co m M ICRONIX PC/104 P OWER S UPPLY PV-1800 SERIES 20W Power Supply including GSM/ GPRS modem, analogue and digital I/O channels V ER .
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 2 / 19 Table of contents GENERAL INFORMATION ...................................................................................................................
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 3 / 19 General informati on Ordering codes Model number Ordering code Description PV-1800-S-1 016.104.088 PV-1800-S-2 016.104.115 PV-1800-S-3 016.104.116 PV-1800-S-4 016.
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 4 / 19 Description The PV-1800, the fully equipped model, offers the following features: • a PC/104 20W power suppl y +5V, 4A.
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 5 / 19 The digital inputs are bipolar isolated with a max. input voltage of +/- 30V. There are 7 isolated digital P-channel outputs each capable of drivin g up to 0.
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 6 / 19 Power Supply The on-board power supply consists of a synchronous step-down switching regulator with an efficiency of 85-95%, depending on input voltage and load current.
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 7 / 19 This table is also printed on the board. The IRQ used for the modem is set in section I RQ_A. Pl ace one jumper in this section to select an IRQ number in the interval IRQ3 to IRQ15.
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 8 / 19 AT commands All functions of the modem are carried out by AT commands from a computer application. For documentation of the AT command set please see “Integrators Manual” for GM47 from Son y Ericsson, at http://www.
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 9 / 19 Analogue inputs (CN5) The PV-1800 has 8 isolated analogue inputs accessible in a 10pin box header (CN5). Beside these inputs, there is also a +3.3V isolated voltage with common ground reference as the analogue inputs.
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 10 / 19 Digital inputs (CN 1) The PV1800 has 8 isolated digital inputs connected to a 10-pin box header (CN1). All the inputs have ac-couplers with a common ground reference.
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 11 / 19 Digital outputs (CN2) The PV1800 has 7 isolated digital outputs connected to a 10pin box header (CN2). The outputs are configured as PNP outputs with their transistors connected to an ext ernal supply voltage (+V_EXT).
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 12 / 19 UPS signals (CN7) The PV-1800 has signals that, combined with external circuitr y, can be used to implement a UPS function.
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 13 / 19 Internal registers Address Access Name Function Base+0 Read onl y REG_SIGN Signature (8Ch) Base+1 Rea.
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 14 / 19 REG_CNTMODE (base+6): Counter configuration (read/write) The counter starts at 0000h after system reset.
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 15 / 19 REG_ADCLO (base+0Ah): ADC command, status, and result low b y te (read/write) Writing to this register starts a new A/D conversion. You should onl y do this when the ADC is idle.
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 16 / 19 Technical data Power supply Input voltage (nominal) 8 – 27 Vdc. Input voltage (MAX) 35Vdc. Output voltage 5Vdc External load Up to 4A, depending on configuration and thermal conditions.
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 17 / 19 Input high voltage: 10 – 24V Max input voltage 30V, current limiti ng resistor = 3.
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 18 / 19 Mechanical Lay o ut This schematic shows the dimensions for PV-1800.
Users Manual & Installation Guide P V- 1800: Pow er supp ly module with GSM MODEM Page 19 / 19 Installation guide Precautions to ESD Please note that the Micronix PV modules must be handled with respect to ESD (Electrostatic Discharge). Electrostatic Discharge to the PV modules must be avoided.
デバイスMicro Technic PV-1800の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Micro Technic PV-1800をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMicro Technic PV-1800の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Micro Technic PV-1800の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Micro Technic PV-1800で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Micro Technic PV-1800を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMicro Technic PV-1800の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Micro Technic PV-1800に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMicro Technic PV-1800デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。