Miller ElectricメーカーBig Blue 600 Xの使用説明書/サービス説明書
ページ先へ移動 of 90
Processes Description TIG (GT A W) Welding Stick (SMAW ) Welding MIG (GMAW) Welding Engine Driven Welding Generator OM-4429 2216 138H 2007 − 05 Visit our website at www.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your near est distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T ABLE OF CONTENTS SECTION 7 − OPERA TING WELDING GENERA TOR − CC/CV MODELS 34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1. Front Panel Controls For CC/CV Models (See Section 7-2) 34 . . . . . . . . . . . . . . . . . . . . . . . .
OM-4429 Page 1 SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING rom_2007 − 04 Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage DANGER! − Indicates a hazardous situation which, if not avoided, will result in death or serious injury .
OM-4429 Page 2 W elding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. FUMES AND GASES can be hazardous. Keep your head out of the fumes. Do not breathe the fumes. If inside, ventilate the area and/or use local forced ventilation at the arc to remove welding fumes and gases.
OM-4429 Page 3 1-3. Engine Hazards BA TTER Y EXPLOSION can BLIND. Always wear a face shield, rubber gloves, and protective clothing when working on a battery . Stop engine before disconnecting or connect- ing battery cables or servicing battery .
OM-4429 Page 4 HOT MET AL from air arc cutting and gouging can cause fire or explosion. Do not cut or gouge near flammables. W atch for fire; keep extinguisher nearby . HOT P ARTS can cause burns and injury . Do not touch hot compressor or air system parts.
OM-4429 Page 5 H. F . RADIA TION can cause interference. High-frequency (H.F .) can interfere with radio navigation, safety services, computers, and communications equipment. Have only qualified persons familiar with electronic equipment perform this installation.
OM-4429 Page 6 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION rom_2007 − 04fre Se protéger , ainsi que toute autre personne travaillant sur les lieux, contre les étincelles et le métal chaud.
OM-4429 Page 7 DES PIÈCES CHAUDES peuvent provoquer des brûlures graves. Ne pas toucher à mains nues les parties chau - des. Prévoir une période de refroidissement avant d e travailler à l’équipement.
OM-4429 Page 8 LES CHAMPS MAGNETIQUES peuv- ent affecter des implants médicaux. Porteur de simulateur cardiaque ou autre im- plants médicaux, rester à distance.
OM-4429 Page 9 L ’utilisation d’un groupe autonome à l’intérieur PEUT VOUS TUER EN QUELQUES MINUTES. Le s fumées d’un groupe autonome contient du monoxyde de carbone. C’est un poison invisi- ble et inodore. JAMAIS utiliser dans une maison ou garage, même avec les portes et fenêtres ouvertes.
OM-4429 Page 10 LE SURCHAUFFEMENT peut endom- mager le moteur électrique. Arrêter ou déconnecter l’équipement avant d e démarrer ou d ’a rrêter le moteur . Ne pas laisser tourner le moteur trop lentement sous risque d’en - dommager l e moteur électrique à cause d’une tension et d’une fré - quence trop faibles.
OM-4429 Page 1 1 2-6. P r oposition californienne 65 A vertissem ents Les équipements de soudage et de coupage produisent des fumées et des gaz qui contiennent des produits chimiques dont l’État de Californie reconnaît qu’ils provoquent des mal- formations congénitales et, dans certains cas, des cancers.
OM-4429 Page 12 SECTION 3 − DEFINITIONS 3-1. W arning Label Definitions (For Wordless Labels) 3/96 1 Remove unit from shipping crate. Remove Owner’s Manual from unit. Follow instructions to install muf fler . 2 Read Owner ’s Manual. Read labels on unit.
OM-4429 Page 13 3-2. Manufacturer ’ s Rating Labels CC Models CC/CV Models.
OM-4429 Page 14 3-3. Symbols And Definitions Some symbols are found only on CE products. Stop Engine Fast (Run, W eld/ Power) Slow (Idle) Start Engine Starting Aid Battery (Engine) Engine Oil Pres.
OM-4429 Page 15 SECTION 4 − SPECIFICA TIONS 4-1. W eld, Power , And Engine Specifications W elding Mode W eld Output Range Rated W elding Output Maximum Open- Circuit V oltage Generator Power Rating.
OM-4429 Page 16 4-3. V olt-Ampere Curves For CC Models 203 412 The volt-ampere curve shows the minimum and maximum voltage an d amperage output capabilities of th e welding generator .
OM-4429 Page 17 4-4. V olt-Ampere Curves For CC/CV Models 217 81 1 / 203 415 / 217 810 The volt-ampere curves show the minimum and maximum voltage an d amperage output capabilities of th e welding generator . Curves of al l other settings fall between the curves shown.
OM-4429 Page 18 4-5. Fuel Consumption The curve shows typical fuel use under weld or power loads. 215 082 − A IDLE DC WELD AMPERES A T 100% DUTY CYCLE U.S. GAL./HR. 0 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 0 50 100 150 200 250 300 350 400 450 500 550 600 Continuous Welding 4-6.
OM-4429 Page 19 4-7. AC Generator Power Curve 193 018 Th e ac power curve shows the gen- erator power in amperes available at the 120 and 240 volt receptacles. 0 50 100 150 200 250 300 0 5 10 15 20 25 30 AC AMPERES IN 240V MODE AC VOL TS 0 25 50 75 100 150 125 0 1 02 03 0 4 05 0 6 0 AC AMPERES IN 120V MODE 4-8.
OM-4429 Page 20 SECTION 5 − INST ALLA TION install3 2007 − 04 − Ref. 800 652 / Ref. 800 477-A / 803 274 / 804 712 ! Always securely fasten weld- ing generator onto transport vehicle or trailer and comply with all DOT and other applica- ble codes.
OM-4429 Page 21 5-2. Using Lifting Eye Ref. 802 31 1 1 Lifting Eye 2 Nut 3 Carriage Bolt Raise lifting eye until it snaps in place. Lower lifting eye when not needed. T o lock the lifting eye in the upright position, insert a 3/8-16 x 1-1/2 in carriage bolt through slot in bracket a nd secure with nut (bolt and nut not supplied).
OM-4429 Page 22 5-3. Mounting Welding Generator T ools Needed: 9/16 in 2 2 4 W elding Unit In Place Bolting Unit In Place ! Do not weld on base. W eld- ing on base can cause fuel tank fire or explosion. Weld only on the four mounting brackets or bolt unit down.
OM-4429 Page 23 5-4. Installing Exhaust Pipe 1/2 in T ools Needed: Ref. 803 604 / Ref. 215 158 ! Stop engine and let cool. Point exhaust pipe in desired di- rection but always away from front panel and direction of travel. Notes W or k l i ke a P r o ! Pros wel d and cut safel y .
OM-4429 Page 24 5-5. Activating The Dry Charge Battery (If Applicable) ! Always wear a face shield, rubber gloves and protective clothing when working on a battery . Remove battery from unit. 5 V ent Caps 6 Sulfuric Acid Electrolyte (1.265 Specific Gravity) 7 W ell Fill each cell with electrolyte to bottom of well (maximum).
OM-4429 Page 25 5-7. Engine Prestart Checks Check all engine fluids daily . Engine must be cold and on a level surface. Unit is shipped with 20W break-in oil. Automatic shutdown system stops engine if oil pressure is too low , coolant temperature is too high, or engine overspeeds.
OM-4429 Page 26 5-8. Connecting T o W eld Output T erminals 803 602 / 803 778-A T ools Needed: 2 3/4 in 1 MIG and FC A W Welding For MIG and FCA W welding Direct Current Electrode Positive (DCEP) on CC/CV models, connect wire feeder cable to Positive (+) termi- nal on left and work cable to Negative ( − ) ter- minal on right.
OM-4429 Page 27 5-9. Selecting W eld Cable Sizes* W eld Cable Size** and T otal Cable (Copper) Length in W eld Circuit Not Exceeding*** 100 ft (30 m) or Less 150 ft (45 m) 200 ft (60 m) 250 ft (70 m) 300 ft (90 m) 350 ft (105 m) 400 ft (120 m) W eld Output T erminals ! Stop engine before connecting to weld output terminals.
OM-4429 Page 28 5-1 1. Connecting T o Remote 14 Receptacle RC14 On CC/CV Models Socket* Socket Information 24 VOL TS AC A 24 volts ac. Protected by sup- plementary protector CB5. 24 VOL TS AC B Contact closure to A completes 24 volt ac contactor control circuit.
OM-4429 Page 29 Notes.
OM-4429 Page 30 SECTION 6 − OPERA TING WELDING GENERA TOR − CC MODELS 6-1. Front Panel Controls For CC Models (See Section 6-2) 12 215 663 / 803 602 11 2 1 81 3 1 4 97 6 4 5 3 10.
OM-4429 Page 31 6-2. Description Of Front Panel Controls For CC Models (See Section 6-1 ) Engine Starting Controls 1 Starting Aid Switch Use switch to energize starting aid for cold weather starting (see starting instructions fol- lowing). 2 Engine Control Switch Use switch to start and stop engine.
OM-4429 Page 32 6-3. Remote Amperage Control On CC Models (Optional) 1 Remote Amperage Adjust Receptacle RC13 Connect optional remote control to RC13 (see Section 5-10 ). Example: Combination Remote Amperage Control (Stick) Adjust Optional Remote Control Set Switches Set Range Set Control Ref.
OM-4429 Page 33 Notes.
OM-4429 Page 34 SECTION 7 − OPERA TING WELDING GENERA TOR − CC/CV MODELS 7-1. Front Panel Controls For CC/CV Models (See Section 7-2) 215 664 / 802 602 13 OR 12 2 1 91 4 1 5 10 7 6 4 5 8 3 11.
OM-4429 Page 35 7-2. Description Of Front Panel Controls For CC/CV Models (See Section 7-1 ) Engine Starting Controls 1 Starting Aid Switch Use switch to energize starting aid for cold weather starting (see starting instructions fol- lowing).
OM-4429 Page 36 7-3. Process/Contactor Switch On CC/CV Models 1 Process/Contactor Switch ! W eld output terminals are ener- gized when Process/Contactor switch is in an Weld T erminals Always On position and the en- gine is running.
OM-4429 Page 37 7-4. Remote V oltage/Amperage Control On CC/CV Models (Optional) 1 Remote 14 Receptacle RC14 Connect optional remote control to RC14 (see Section 5-1 1).
OM-4429 Page 38 SECTION 8 − OPERA TING AUXILIAR Y EQUIPMENT 8-1. 120 V olt And 240 V olt Receptacles 191 624-A 2 1 120 V 20 A AC GFCI Receptacle GFCI1 2 240 V 30 A AC T wistlock Receptacle RC1 Receptacles supply 60 Hz single- phase power at weld/power speed.
OM-4429 Page 39 8-2. Connecting T o Optional Three-Phase Generator (CC/CV Models Only) Ref. 197 399 / 802 332-E / 803 655 Place Process/Contactor switch in W eld T erminals Always On - Stick position when using three- phase generator (see Section 7-3 ).
OM-4429 Page 40 8-3. Optional Generator Power Receptacles 2 1 120 V 20 A AC GFCI Receptacle GFCI1 2 240 V 16 A AC European Receptacle RC1 3 240 V 15 A AC Australian Receptacle RC1 4 240 V 15 A AC South African Receptacle RC1 Receptacles supply 60 Hz single- phase power at weld/power speed.
OM-4429 Page 41 SECTION 9 − MAINTENANCE & TROUBLESHOOTING 9-1. Maintenance Label.
OM-4429 Page 42 9-2. Routine Maintenance ! Stop engine before maintaining. S ee Engine Manual and Maintenance Label for important start-up, service, and storage information. Service engine more often if used in severe conditions. Recycle engine fluids.
OM-4429 Page 43 9-3. Servicing Air Cleaner ! Stop engine. NOTICE − Do not run engine without air cleaner or with dirty element. Engine damage caused by using a damaged ele- ment is not covered by the warranty . The air cleaner primary element can be cleaned but the dirt holding capac- ity of the filter is reduced with each cleaning.
OM-4429 Page 44 9-4. Inspecting And Cleaning Optional Spark Arrestor Muffler 803 656 / Ref. 215 158 ! Stop engine and let cool. 1 Spark Arrestor Muffler 2 Cleanout Plug Remove plug and remove any dirt covering cleanout hole. Start engine and run at idle speed to blow out cleanout hole.
OM-4429 Page 45 9-6. Servicing Fuel And Lubrication Systems 802 490 / Ref. 801 434 ! Stop engine and let cool. ! After servicing, start engine and check for fuel leaks.
OM-4429 Page 46 9-7. Overload Protection 803 605 21 9 8 7 4 ! Stop engine. When a supplementary protector , circuit breaker or fuse opens, it usu- ally indicates a more serious problem exists. Contact Factory Authorized Service Agent. 1 Fuse F1 2 Fuse F2 F1 and F2 protect the stator exciter wind- ing from overload.
OM-4429 Page 47 9-8. T roubleshooting A. Welding − CC Models T rouble Remedy No weld output; generator power output okay at ac receptacles. Check position of Ampere Range switch.
OM-4429 Page 48 B. Welding − CC/CV Models T rouble Remedy No weld output; generator power output okay at ac receptacles. Place Process/Contactor switch in a Weld T erminals Always On position, or pl.
OM-4429 Page 49 T rouble Remedy Check and secure connections to Remote 14 receptacle RC14 (see Section 5-1 1). Repair or replace wire feeder . Low CV weld output. Set Ampere Range switch to highest range. Increase V oltage/Amperage Adjust Control setting.
OM-4429 Page 50 T rouble Remedy Check engine wiring harness plug connections. Have Factory Authorized Service Agent check control relay CR1, diode/capacitor board D8/C8, and En- gine Control switch S1. Engine cranks but does not start. Check fuel level.
OM-4429 Page 51 Notes Over 80,000 trained since 1930! 400 T rade Square East, T roy , Ohio 45373 1-800-332-9448 www.welding.org Star t Y our Pr ofessional W elding Career Now!.
OM-4429 Page 52 SECTION 10 − ELECTRICAL DIAGRAMS Figure 10-1. Circuit Diagram For CC Welding Generator.
OM-4429 Page 53 223 525-B.
OM-4429 Page 54 Figure 10-2. Circuit Diagram For CC/CV Welding Generator.
OM-4429 Page 55 223 524-B.
OM-4429 Page 56 SECTION 1 1 − RUN-IN PROCEDURE run_in1 2007 − 04 1 1-1. Wetstacking 1 W elding Generator Ru n diesel engines near rated volt- ag e and current during run-in period to properly seat piston rings and prevent wetstacking. See name- plate, rating label, or specifications section in this manual to find rated voltage and current.
OM-4429 Page 57 1 1-2. Run-In Procedure Using Load Bank S-0683 1 Load Bank T urn all load bank switches Of f. If needed, connect load bank to 1 15 volts ac wall receptacle or genera- tor auxiliary power receptacle.
OM-4429 Page 58 1 1-3. Run-In Procedure Using Resistance Grid S-0684 1 Resistance Grid Use grid sized for generator rated output. Turn O f f grid. 2 Welding Generator Place A/V range switch in maxi- mum position, A/V control in mini- mum position, and Output Selector switch (if present) in either DC position.
OM-4429 Page 59 SECTION 12 − GENERA TOR POWER GUIDELINES The views in this section are intended to be representative of all engine-driven welding generators. Y our unit may differ from those shown. 12-1. Selecting Equipment gen_pwr 2007 − 04 − Ref.
OM-4429 Page 60 12-3. Grounding When Supplying Building Systems ST-800 576-B 1 Equipment Grounding T erminal 2 Grounding Cable Use #10 AWG or larger insulated copper wire. 3 Ground Device Us e ground device as stated in electrical codes. ! Ground generator to system earth ground if supplying power to a premises (home, shop, farm) wiring system.
OM-4429 Page 61 12-5. Approximate Power Requirements For Industrial Motors Industrial Motors Rating Star ting W atts Running W atts Split Phase 1/8 HP 800 300 1/6 HP 1225 500 1/4 HP 1600 600 1/3 HP 21.
OM-4429 Page 62 12-7. Approximate Power Requirements For Contractor Equipment Contractor Rating Starting W atts Running W atts Hand Drill 1/4 in 350 350 3/8 in 400 400 1/2 in 600 600 Circular Saw 6-1/.
OM-4429 Page 63 12-8. Power Required T o Start Motor Single-Phase Induction Motor Starting Requirements Motor Start Code G H J K L M N P KV A/HP 6.3 7.1 8.0 9.0 10.0 1 1.2 12.5 14.0 S-0624 1 Motor Start Code 2 Running Amperage 3 Motor HP 4 Motor V oltage T o find starting amperage: Step 1: Find code and use table to find kV A/HP .
OM-4429 Page 64 12-10. T ypical Connections T o Supply Standby Power T ransfer Switch Essential Loads Fused Disconnect Switch (If Required) Utility Electrical Service 12 3 4 5 W elding Generator Output ! Have only qualified persons perform these connections according to all applicable codes and safety practices.
OM-4429 Page 65 12-1 1. Selecting Extension Cord (Use Shortest Cord Possible) Cord Lengths for 120 V olt Loads If unit does not have GFCI receptacles, use GFCI-protected extension cord.
OM-4429 Page 66 SECTION 13 − P ARTS LIST Hardware is common and not available unless listed. 1 2 3 4 5 7 6 8 9 10 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 101 102 103 104 105 100 106 107 108 (CC) 109 (CC) 11 0 1 1 1 (Fig. 13 − 2 11 2 11 3 1 14 (Fig.
OM-4429 Page 67 803 844-B 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 88 (Fig.
OM-4429 Page 68 Description Part No. Dia. Mkgs. Item No. Figure 13-1. Main Assembly Quantity 1 189 824 Panel, Gen Lh 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-4429 Page 69 Description Part No. Dia. Mkgs. Item No. Figure 13-1. Main Assembly (Continued) Quantity 39 216 133 Engine, Perkins Dsl Elec 404C − 22T 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-4429 Page 70 Description Part No. Dia. Mkgs. Item No. Figure 13-1. Main Assembly (Continued) Quantity 77 190 190 T ank, Coolant Recovery 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-4429 Page 71 Description Part No. Dia. Mkgs. Item No. Figure 13-1. Main Assembly (Continued) Quantity 123 212 944 Label, Weld Control/Arc Condition Information Label 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 233 088 Label, Danger Using A Generator Indoors Can Kill Y ou In Minutes (Unit) 1 .
OM-4429 Page 72 803 845-D 2 1 23 5 4 3 6 20 18 21 16 15 17 8 11 7 12 19 13 9 10 14 22 Figure 13-2. Control Box Assembly − CC Models.
OM-4429 Page 73 Description Part No. Dia. Mkgs. Item No. Figure 13-2. Control Box Assembly − CC Models (Figure 13-1 Item 1 1 1) Quantity 1 F1, F2 *085 874 FUSE, mintr cer slo-blo 10A 250V 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-4429 Page 74 803 846-D 22 1 2 3 15 19 17 18 16 14 13 8 4 9 12 21 20 10 5 6 7 11 Figure 13-3. Control Box Assembly − CC/CV Models Description Part No. Dia. Mkgs. Item No. Figure 13-3. Control Box Assembly − CC/CV Models (Figure 13-1 Item 1 1 1) Quantity 1 F1, F2 *085 874 FUSE, mintr cer slo-blo 10A 250V 2 .
OM-4429 Page 75 Description Part No. Dia. Mkgs. Item No. Figure 13-3. Control Box Assembly − CC/CV Models (Continued) Quantity 17 134 201 ST AND-OFF , support pc card 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-4429 Page 76 Hardware is common and not available unless listed. 803 649 1 2 3 4 5 6 7 8 9 11 10 12 13 14 15 16 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 34 33 35 36 37 38 39 40 41 42 17 Figure 13-4. Panel, Front w/Components − CC Models Description Part No.
OM-4429 Page 77 Description Part No. Dia. Mkgs. Item No. Figure 13-4. Panel, Front w/Components − CC Models (Continued) Quantity 3 215 014 P ANEL, engine/weld control 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-4429 Page 78 Hardware is common and not available unless listed. 803 650 11 31 14 30 27 54 42 53 52 51 50 46 47 49 48 44 39 40 41 38 37 36 35 43 34 29 28 33 2 56 55 57 58 1 7 6 8 10 9 3 5 4 19 24 20 25 26 22 23 21 17 16 15 18 13 12 32 45 Figure 13-5.
OM-4429 Page 79 Description Part No. Dia. Mkgs. Item No. Figure 13-5. Panel, Front w/Components − CC/CV Models (Continued) Quantity 12 S2 021 467 SWITCH, tgl spst 3a 250v off − none − (on) spd term 1 . . . . . . . . . . . . . . . . . . . . . . .
OM-4429 Page 80 55 097 922 KNOB, pointer .875 dia x .250 ID w/set screws plstc 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 189 161 HANDLE, switch range 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-4429 Page 81 Description Part No. Dia. Mkgs. Item No. Figure 13-6. Generator (Continued) Quantity 12 210 446 ROTOR, Generator (Includes) 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-4429 Page 82 Hardware is common and not available unless listed. 802 279-A 1 2 3 4 6 5 7 8 9 Figure 13-7. Main Rectifier Assembly Description Part No. Dia. Mkgs. Item No. Figure 13-7. Main Rectifier Assembly (Figure 13-1 Item 1 14) Quantity SR3 215 910 RECTIFIER, environmental (consisting of) 1 .
OM-4429 Page 83 Some wiring harness components (switches, relays, circuit breakers) are also referenced elsewhere in this parts list. Purchase components sepa- rately or as part of the associated wiring harness. Description Part No. Dia. Mkgs. Item No.
OM-4429 Page 84 215207 Harness, Unit Weld Control CV (Includes) 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLG6 1 14063 Conn, Rect Univ 084 4p/S 1row Plug Cable Lkg 1 . . . . . . . . . . . . . . . . .
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2007 − 01 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours.
PRINTED IN USA © 2007 Miller Electric Mfg. Co. 2007 − 01 Miller Elect ric Mfg. Co. An Illinois T ool Wo rks Compa ny 1635 West S pencer S treet Applet on, WI 5 4914 US A International He adquarters.
デバイスMiller Electric Big Blue 600 Xの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Miller Electric Big Blue 600 Xをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMiller Electric Big Blue 600 Xの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Miller Electric Big Blue 600 Xの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Miller Electric Big Blue 600 Xで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Miller Electric Big Blue 600 Xを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMiller Electric Big Blue 600 Xの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Miller Electric Big Blue 600 Xに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMiller Electric Big Blue 600 Xデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。