Visit our website at w ww .Mi llerWelds.co m Spectrum 2050 Processes Descrip tio n Air Plasma Cutting and Gouging Air Plasma Cutter OM -2220 190 444H November 1999 R.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
OM-2220 Page 1 SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING pom _nd_9/98 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message.
OM-2220 Page 2 D On inverter power sources, failed parts can ex- plode or cause other parts to explode when power is applied. Always wear a face shield and long sleeves when servicing inverters. EXPLODING P ARTS can injure. Sparks and hot metal blow out from the cutting arc.
OM-2220 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance HOT P ARTS can cause severe burns. D Do not touch hot parts bare handed. D Allow cooling period before working on torch. MOVING P ARTS can cause injury . D Keep away from moving parts such as fans.
OM-2220 Page 4 1-4. Principal Safety Standards Safety in Welding and Cutting , ANSI Standard Z49.1, from American W elding Society , 550 N.W . LeJeune Rd, Miami FL 33126 Safety and Health Standards , OSHA 29 CFR 1910, from Superinten- dent o f Documents, U.
OM-2220 Page 5 SECTION 1 – CONSIGNES DE S É CURIT É – LIRE A V ANT UTILISA TION pom_nd_fre_5/97 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette proc é dure pr é sente des risques de danger ! Ceux-ci sont identifi é s par des symboles adjacents aux directives.
OM-2220 Page 6 D N ’ approchez pas le tube du chalumeau et l ’ arc pilote lorsque la g â chette est enfonc é e. D Le c â ble de masse doit ê tre pinc é correctement sur la pi è ce à couper .
OM-2220 Page 7 1-3. Dangers suppl é mentaires en relation avec l ’ installation, le fonctionnement et la maintenance DES PIECES CHAUDES peuvent pro- voquer des br û lures graves. D Ne pas toucher des parties chaudes à mains nues. D Laisser refroidir avant d ’ intervenir sur la torche.
OM-2220 Page 8 1-5. Information sur les champs é lectromagn é tiques Donn é es sur le soudage é lectrique et sur les ef fets, pour l ’ organisme, des champs magn é tiques basse fr é quence Le courant de soudage ou de coupage passant dans les c â bles de puis- sance c r é e des causera des champs é lectromagn é tiques.
OM-2220 Page 9 SECTION 2 – INST ALLA TION 2-1. Specifications For any single or three phase voltage from 208 V to 575 V , the Amperes Input at Rated Load Output is the same for 50 Hertz or 60 Hertz input power . For example, the amperes input for 230 V , 50 Hz, single-phase input power is 33 amperes.
OM-2220 Page 10 6 Minutes Cutting 4 Minutes Resting 2-2. Duty Cycle and Overheating Duty Cycle is percentage of 10 m i n- utes that unit can cut at rated load without overheating. If unit overheats, thermostat(s) opens, output stops, and cooling fan runs.
OM-2220 Page 1 1 2-4. Selecting a Location loc_2 3/96 - Ref. ST-151 556 / ST -802 183 1 Lifting Handles Use handles to lift unit. 2 Hand Cart Use cart or similar device to move unit. 3 Rating Data on Rear Nameplate Use rating data to determine input power needs.
OM-2220 Page 12 2-5. Connecting W ork Clamp and Gas/Air Supply 1 Work Clamp 2 W orkpiece Connect work clamp to a clean, paint-free location on workpiece, as close to cutting area as possible. . Use only clean, dry air with 90 to 150 psi (620 to 1035 kPa) pressure.
OM-2220 Page 13 50 Hz Models Single Phase Three Phase Input V oltage 230 230 380 400 415 Input Amperes At Rated Output 33 20 10 10 10 Max Recommended Standard Fuse Rating In Amperes 1 Time-Delay 2 40 .
OM-2220 Page 14 2-8. Connecting Input Power L1 input_2 3/96 - Ref. ST-144 221 / Ref. ST -070 399-C / ST-802 183 Check input voltage available at site. . Th e Auto-Line E circuitry in this unit automatically adapts the power source to the primary voltage being applied, from 2 0 8 to 575 volts, single- or three- phase, 50 or 60 H z .
OM-2220 Page 15 SECTION 3 – OPERA TION 3-1. Controls 1 Gas/Air Pressure Gauge 2 Gas/Air Pressure Control 3 Output Control Use control to select cutting output in am- peres. Gas/air automatically flows at the set pressure. Us e Gas/Air Set area of control range for set- ting gas/air pressure (see Section 3-2).
OM-2220 Page 16 1 Output Control 2 Power Switch Place controls as indicated above. Only gas/ air circuit is activated when the Power switch is turned On with Output Control in Gas/Air Set position. 3 Gas/Air Pressure Adjustment Knob Pull knob and turn to adjust pressure.
OM-2220 Page 17 3-3. Sequence of Operation Put On Personal Safety Equipment After cutting arc starts, slowly start moving torch across metal. Adjust torch speed so sparks go thru metal and out bottom of cut. Pause briefly at end of cut before releasing trigger .
OM-2220 Page 18 SECTION 4 – MAINTENANCE & TROUBLESHOOTING 4-1. Routine Maintenance Y Disconnect power before maintaining. . Maintain more often during severe conditions.
OM-2220 Page 19 4-2. T rouble Lights 1 Pressure Light Lights if gas/air pressure is below 40 PSI (276 kPa). Tur n power Of f, and check for prop- er gas/air pressure (see Section 3-2). 2 Cup Light Lights if shield cup is loose. T urn power Off, and check shield cup connection (see torch Owner ’ s Manual).
OM-2220 Page 20 4-4. T roubleshooting T rouble Remedy No pilot arc; dif ficulty in establishing an arc. Clean or replace worn consumables as necessary (see torch Owner ’ s Manual). Check for damaged torch or torch cable (see torch Owner ’ s Manual).
OM-2220 Page 21 Notes.
OM-2220 Page 22 SECTION 5 – ELECTRICAL DIAGRAM Figure 5-1. Circuit Diagram For Power Source.
OM-2220 Page 23 197 286-A.
OM-2220 Page 24 SECTION 6 – P ARTS LIST ST-802 184-E . Hardware is common and not available unless listed. 4 5 6 10 11 16 22 23 37 39 43 52 53 19 12 13 15 49 50 27 28 51 28 25 Figure 6-1.
OM-2220 Page 25 Description Part No. Dia. Mkgs. Item No. Figure 6-1. Main Assembly Quantity 1 187 782 WRAPPER 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Notes.
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 7/00 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor .
PRINTED IN USA 2000 Miller Electric Mfg. Co. 6/00 Miller Elect ric Mfg. Co. An I l li noi s T ool Works Company 1635 West Spenc er St reet Applet on, W I 54914 US A International He adquarte rs .
デバイスMiller Electric Spectrum 2050の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Miller Electric Spectrum 2050をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMiller Electric Spectrum 2050の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Miller Electric Spectrum 2050の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Miller Electric Spectrum 2050で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Miller Electric Spectrum 2050を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMiller Electric Spectrum 2050の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Miller Electric Spectrum 2050に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMiller Electric Spectrum 2050デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。