These quick start instruc tions allow you to begin detecting straight away and fi nd important reference information for setting up your X - T erra 70. Minelab encourages all users to read the entire manual to ensure a complete understanding of all the features and functions that your X- T err a 70 off ers.
The W orld L eader in Metal Sensing T echnology From our origins in 1985, Minelab have specialised in adv anced electronics technologies. Our competitive adv antage was created almost immediately with a highly competent and innovativ e Research and Development team, inspired by the genius of Mr .
Menu Operation 28 Adjusting Menu Settings 29 Sensitivity 30 Adjusting Sensitivity 3 1 Vo l u m e 32 Adjus tin g Volume 33 Noise Canc el 34 Choosing a Noise Cancel Channel 3 5 Thre shold 3 6 Adjusting .
2 Metal detec tors create an elec tro - magnetic field, which p enetrates the ground. Because metal is c o nductive it causes a change in this f ield. T he detector senses this change and sends a signal back to the control box, aler ting the o perator .
5 ASS EMBLING Y OUR X- TERR A 70 Connecting the Coil Plug the two rubber washer s int o the holes on either side of the lower shaft yoke. Slide the yoke int o the yoke bracket on top of the coil. En sure that the spring loaded pin in the lower shaf t is underneath the c oil shaf t, pointing downwards.
ASS EMBLING Y OUR X- TERR A 70 6 Coil C able Assembly Wind the coil cable around the lower and middle shaf t enough times to take up the slack. Use the velcro tabs to keep the coil cable in place against the shaf t.
8 9 PATTERNS Scrolls through the dif ferent Discrimi nation Patterns (Coin & T reasure Mode only). KE Y P A D L A YO U T POW ER T urns the detec tor on/ of f. Adjusts set tings, reduces Iron Mask and scrolls to the lef t through the discrimination segments.
10 11 Ground Balance c an only be accessed via the GROUND BALANCE button) Pat ter ns Preset Disc rimination Patterns are used to suit dif ferent sear ch preferences (C oin & T reasure M ode only). The X- T erra 70 has three pat terns . (Preset Discrimination Patterns , pg.
12 13 It is best to only turn the detector on, when outdoors, away from sourc es of elec tromagnetic disturbance. There are many metallic objec ts inside a house (e.g. nails in the f loor , reinforcing in the walls) that migh t overload the electronic s of the detector .
14 15 T o hold the detec tor , thread your arm through the armrest and strap. Grasp the handle of the detector and rest your forearm in the armrest. Y o ur elbow should sit just above the top of the armrest. Lightly tighten the velcro strap and secure it around your arm.
17 Ta r g e t R e s p o n s e (Metal Object Response) This is the sound given by the detector when a target is located and not discriminated (rejec ted). In Coin & T reasure Mode, a target that is highly conductive (e.g. a large silver coin) generally causes a high tone beep and ferrous targets generally cause a low tone beep.
18 19 19 18 PR OSPECTING MODE Coin & T reasure Mode is used for detec ting valuable objec ts, including old and mo dern coins, jeweller y and ar tifac ts . Undesired objec ts such as pull-t abs and bottle c aps may be rejected . This mode can be used in a variet y of environments, such as park s and salt water beaches.
21 Buried metal objec ts are re ferred to as targets . T arget signals contain ferrous and conductivit y information. As the coil is passed over a target, the detector digitally processes the target signal and displays this as a number . T arget Identif ication ( ID) is used to distinguish one t ype of metal t arget from anothe r .
22 The X- T erra 70 has an All Metal Pattern, three preset Discrimination Patterns and Iron Mask. The combinations of ac cepted and rejec ted segments are referred to as Discrimination Patterns. The X - T erra 7 0 has preset Discrimination Patterns that hav e been cus tomised to detect general desired target s, such as coins and jeweller y .
25 24 The Preset Discriminatio n Patterns may be edited to create custom patterns. Method 1 - to reject a specific T arget ID using an actual target When detecting a target, a discrimination segment will f lash, indicating its position on the discrimination scale and the target ’ s ID number will appear on the LCD.
The X- T erra 70 updates the T arget ID and Depth whilst Pinpointing in Coin & T reasure Mode. PINP OI NTI NG 26 When a signal is heard, it is an advantage to identif y the e xac t position of the t arget.
28 29 Dete ct ion (d isplay st ate) In Coin & T reasure Mode, the T arget ID, discrimination segments and depth automatically translat e target signals.
30 31 The X- T erra 70 is highly sensitiv e and has a wide Sensitivity adjustment range. It is impor tant to set the correct Sensitivit y level for your detecting conditions. Sensitivity is the detec tor’ s level of response to a target and its environmen t.
32 33 V o lume is the level of sound emitted by the detector when a target is detec ted. The Volume c ontrol limits the ma ximum volume of target signals. The sound produced by a distant target star ts sof tly . As you get closer , the volume level increases rapidly until it reaches the maximum level that has been set .
34 35 The detec tor ma y become noisy or erratic due to electrical inter ference from powerlines, ele ctrical e quipment or other detectors operating close by . Thi s inte r fer ence is inte rpr ete d as a crackling or popping noise. Noise Cancel allows you to change the noise cancel channel so that you experience less interference.
36 37 ADJUSTING THR ESHOLD Threshold is the constant ba ckground sound produced by the detector to help distinguish bet ween desirabl e and undesirable targets. When a rejec ted target is detected, the Threshold sound ‘blank s’ (b ecomes silent) t o indic ate tha t a rejec ted target is underneath th e coil.
38 39 TONES ADJUSTING TONES Ta r g e t To n e s The number of T arget T ones may be selec ted from the T ones menu. There are f ive dif ferent options listed in the table b elow . Threshold T one In Prospec ting Mode, the pitch of the Threshold T one can b e adjusted using the T o nes menu.
40 41 The X-t erra 70 is capable of operating in two dif ferent t yp es of grounds, magnetic (ie. inland park s) and conductive (wet areas of salt water beaches).
When Pinpoint is activated , T racking Ground Balance is automatically disabled . When Pinpoint is deactivated , T racking Ground Balance is automatically re-enabled. Tr a c k T r acking Ground Balanc e follows the changes in gro und conditio ns and consta ntly adjust s the Grou nd Balan ce while dete ctin g.
44 45 FAC T O RY P R E S E T S Erasin g Pa tterns Cu stom patterns are saved when the X - T erra 70 is switched off. T o erase cus tom patterns and return to preset patterns: T urn the detec tor of f . While pressing and holding PATTERNS , turn the detector back on by pressing POW ER once.
46 47 SOUNDS Threshold This is the background ‘buz z ’ given by the detector , to help distinguish between ac cep ted a nd reject ed targ ets. Blanking When a rejec ted target is detected, the Threshold sound ‘blank s’ (b ecomes silent) t o indic ate tha t a rejec ted target is underneath th e coil.
C OIL IDENTIFIC A TION 48 49 The X- T erra 70 is capable of operating at three dif ferent transmission frequencies set by VFLEX compatible coils. Stan dar d (7 . 5k H z) This frequenc y is most suitab le for general detecting for most ground conditions.
50 51 When not using headphones, keep the rubber cover closed to pr otect the control box electronics from moisture and dust. A CC ESSORIES Skid Plate A skid plate comes as standard with the detec tor . If it wears out from excessiv e sweeping along the ground, acce ssor y skidplates are available for purchase.
52 53 X - TERRA 70 SPECIFICA TIONS Tr a n s m i s s i o n Singl e Freque nc y Sin e Wave Te c h n o l o g y VFLEX Coi l 9” Concentr ic 7 . 5 kHz Visu al Displ ay Positive Ref lec tive LCD Audio Inte.
54 55 US ER PR EFERENC ES USER NOTES.
To d a y ’s D a t e Detec tor / Mode l Serial Number Purc hase d From Purc hase D ate Fa u l t y P a r t ( s ) Owner’ s Name Addr ess T e lephone ( ) Day Home F a x ( ) Email SERV IC E REP AIR FOR.
デバイスMinelab 4901 - 0059の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Minelab 4901 - 0059をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMinelab 4901 - 0059の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Minelab 4901 - 0059の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Minelab 4901 - 0059で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Minelab 4901 - 0059を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMinelab 4901 - 0059の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Minelab 4901 - 0059に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMinelab 4901 - 0059デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。