User ’ s Manual (Hardware) AJ65BT -D75P2-S3 Thank you fo r purchasing the Mitsubishi general- purpose programmable logic contro ller MELSEC- A series. © 201 1 MITSUBISHI ELECTRIC CORP ORA TION AJ65BT -D75P2-S3 Positioning Module Prior to use, pleas e read t his and r elevant manuals t horougly t o fully understand the product.
A-1 SAFETY PRECAUTIONS (Read these precautions before using.) When using Mitsubishi equipment , thoroughly read thi s manual and the associated manuals introduced in the manual. Also pay careful atten tion to safety and handle the module properly . These precautions apply only to Mitsubish i equipment.
A-2 [Design Precautions] [Design Precaution] [Installation Precautions] W ARNING ● When data lin k becomes faulty , the operation of communication f aulty station vary depending on its dat a link type.
A-3 [Wiring/Connection Precautions] CAUTION ● Be sure to shut o ff all phases of t he external power supply used by the system before in stallation or wiring. Not doing so can cause the product to be damaged or malf unction. ● Be sure to ground the FG terminal to the class-D (class-3) or higher grounding.
A-4 [Wiring/Connection Precautions] [St artu p and Maintenance Precautions] [Disposal Precautions] CAUTION ● When disconnecting the co mmunication and power supply cables from the module, do not hold and pull the cable p art. Disconnect the cab les after loosening the screws in the portions connected to the module.
A-5.
A-6.
A-7.
A-8 CONDITIONS OF USE FOR THE PRODUCT (1) Mitsubishi progr ammable controller ("th e PRODUCT") shall be u sed in conditions; i) where any proble m, fault or failure occurring i n the PRODUCT.
A-9 Notwithstandi ng the above, restrictions Mitsubish i may in its so le discretion, authorize use of the PRODUCT in one or more of the Prohibite d Applications, provided t hat the usage of the PRODU.
A-10 ABOUT THE MANUALS The following product are available fo r this equipment. Refer to the tab le given below to choose suit able manuals. COMPLIANCE WITH THE EMC AND LOW VOL T AGE DIRECTIVES 1) Met.
A-11 CONTENTS 1. OVERVIE W ........... ........... .......... .......... ........... .......... ........... ............. ........... .. 1 2. PERFORM ANCE SPE CIFICATIONS ...................... .......... ........... ............. ..... 1 3. NAME O F EACH PART .
1 1. OVERVIEW This manual describes how to insta ll AJ65BT -D75P2-S3 Positioning Module (hereaft er abbreviated as D75P2) and how to wire them with external devices. After u npacking D75P2, please con firm that the f ollowing product s are contained. 2.
2 3. NAME OF EACH P A RT No. Name Description 1) Corresponding ax is LED display Indicates the axis for t he "8)17 segm ent LED" message. 2) CC-Link st atus LED displ ay Shows the powe r supply and d ata communication conditions. 3) Transmission speed setting switch Sets the data co mmunication sp eed.
3 *1 For modules of the hardware version L o r later , the display pa rt is changed to a LED module. (The display content s remain the same as the 17-segment LED.
4 4. LOADING AND INST ALLA TION The following is explanations of the handling precautions and installation en vironment which is common to modules when handling D75P2 from unpacki ng to installation. For the details of loading and installation of the module, refer to User's Manual of programmable controll er CPU module to be used.
5 5. WIRING DA T A-LINK CA BLES This section describes the method for wiring a twisted cable between the D75P2 and master module. 5.1 Precautionary items when handling twisted cables Do not handle t he twisted cables in t he following manner . These extreme activities will damage the cables.
6 6. EXTERNAL WIRING Precautionary notes when wiring as well as the I/ O interface are described below . 6.1 Precautionary notes when wiring This section d escribes the pr ecauti onary notes for the wiring process between the D75P2 and out side (drive unit).
7 6.2 I/O Interface : Wiring re quired, : Wiring performed as required I/O classification External wiring Pin number Internal circuit Signal name Wiring requirement Input 11 Near-point signal DOG 12 H.
8 *1 Select open collector output or different ial output, according to the drive unit used. Remarks The following shows the rela tionship between the pulse output mode selected via the parameter and the pulse output according to "positive logic/negative logic selecti on.
9 * T o construct an absolute position detection syst em, perform wiring as shown below: Remarks *2 Signals in the ABS transfer mode are shown. *3 Signals in the normal state (not in the ABS transfer mode ) are shown. For details, refer to t he specification/instruction manual for the servo amplifier used.
10 7. EXTERNAL DIMENSIONS Unit:mm (inch) 170 71 80 161 2- 4.5 installation hole 9.5 63.5.
11 MEMO.
Country/Region Sales office/Tel Specifications subject to change without notice. Country/Region Sales office/Tel U.S.A Mitsubishi Electric Automation Inc. 500 Corporate Woods Parkway V ernon Hills, IL 60061, U.S.A. T el : +1-847-478-2100 Brazil MELCO-TEC Rep.
デバイスMitsubishi Electronics AJ65BT-D75P2-U-HEの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Mitsubishi Electronics AJ65BT-D75P2-U-HEをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMitsubishi Electronics AJ65BT-D75P2-U-HEの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Mitsubishi Electronics AJ65BT-D75P2-U-HEの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Mitsubishi Electronics AJ65BT-D75P2-U-HEで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Mitsubishi Electronics AJ65BT-D75P2-U-HEを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMitsubishi Electronics AJ65BT-D75P2-U-HEの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Mitsubishi Electronics AJ65BT-D75P2-U-HEに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMitsubishi Electronics AJ65BT-D75P2-U-HEデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。