FX 3U SERIES PROGRA MMABLE CONTROLLERS HARDWARE MANUAL This manual describes the part names, dimensions, mounting, cabling and specifica tions for the pro duct. This manual is extracted from FX 3U Series User's Manual - Hardware Edition. Refer to FX 3U Series User's Manual - Hardwa re Edition for more details.
Requirement for Compliance with LVD directive The following produ cts have shown compli ance through di rect testing (of t he identified standards bel ow) and desig n analysis (through the cr eation of a t echnical construct ion file) to the Europea n Directive for Low Voltage ( 2006/95/E C) when used as directed by the approp riate docume ntation.
With terminal cover open 1.2 External dimensions and we ight *1 FX 3U -32MR/UA1 uses 4- φ 4.5 mounting holes. *2 Except FX 3U -32MR/UA1 *3 FX 3U -32MR/UA1 is equivalen t to FX 3U -48M . *4 FX 3U -64MR/UA1 is equi valent to FX 3U -80M . Installation • 35 -m m -w id e DI N r a il o r D ir ec t (s cr e w) m ou nt i ng (M 4) 2.
2.2 Installation location Install the PLC in a n environmen t conformin g to the generic specific ations (s ection 2. 1), i nstallat ion preca utions a nd notes.
3.1 Wiring 3.1.1 Cable end treatment and tightening torque For the terminals of FX 3U serie s PLC, M3 screws ar e used. The electric wire ends shou ld be treated as shown below . Tighten the screws t o a torque of 0.5 to 0.8 N • m. Do not tighten term inal screws exceeding the specified torq ue.
*1 Each value inside ( ) indicates the n u mber of occupi ed points. 3.4.2 Examples of 24V DC input wiring[AC power type] 3.4.3 Examples of 24V DC input wiring[DC power type] Input connecting type Ref.
3.4.6 Examples of 100V AC input wiring 3.5 Relay output specifications and example of external wiring As for the details o f Instructions for conn ecting input devices, refer to the following manual. → Refer to FX 3U Series User's Manual - Hardware Edition.
*1 The total load current of resistance loads per common terminal should be the following valu e or less. - 1 output point/commo n terminal : 0.5A - 4 output point/commo n terminal : 0.
デバイスMitsubishi Electronics FX3uの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Mitsubishi Electronics FX3uをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMitsubishi Electronics FX3uの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Mitsubishi Electronics FX3uの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Mitsubishi Electronics FX3uで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Mitsubishi Electronics FX3uを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMitsubishi Electronics FX3uの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Mitsubishi Electronics FX3uに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMitsubishi Electronics FX3uデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。