1. BEFORE INST ALLA TION 1-1. THE FOLLOWING SHOULD AL W A YS BE OBSERVED FOR SAFETY • Be sure to read these safety precautions and instructions. %HVXUHWRREVHUYHWKHZDUQLQJVDQGFDXWLRQVVSHFL¿HGKHUH • After reading this manual, be sure to store it with the OPERATING INSTRUCTIONS for future reference.
(OHFWULFDOVSHFL¿FDWLRQV MODEL MSZ-FD09/12NA INDOOR UNIT Power supply (V , PHASE, Hz) 208/230, 1, 60 Min. Circuit Ampacity (A) 1.0 Fan motor (F .L.A.) (A) 0.76 OUTDOOR UNIT Power supply (V , PHASE, Hz) 208/230, 1, 60 Max. Fuse size (time delay) (A) 15 Min.
1-4. INST ALLA TION DIAGRAM ACCESSORIES Check the following parts before installation. <Indoor unit> (1) Installation plate 1 (2) Attachment screws for the installa- tion plate 4×2 5m m 5 (3) Remote controller holder 1 (4) Screws for the remote controller holder 3.
• Connect wires to the appropriate terminals • For future servicing, leave some slack in the connecting wires. • Make ground wire a little longer than others. (More than 1-9/16 in. [40 mm]) 2-1. A TT ACHING THE INST ALLA TION PLA TE • Find a stud in the wall to attach installation plate (1) horizontally on the wall with screws (2).
2-4-2. DRAIN PIPING • If the extension drain hose has to pass through a room, be sure to wrap it with insu- ODWLRQ¿HOGVXSSOLHG • The drain hose should point downward for easy drain.
3-1. CONNECTING WIRES FOR OUTDOOR UNIT 1) Remove the service panel. 2) Remove the conduit cover. 3) Attach the conduit connector to conduit plate with lock nut then secure it against unit with screws. 4) Connect ground wires of indoor/outdoor unit connecting wire (A) and power supply cord (K) to the TB support.
3-3. PIPE CONNECTION )DVWHQÀDUHQXWZLWKDWRUTXHZUHQFKDVVSHFL¿HGLQWKHWDEOHUHIHUWR :KHQIDVWHQHGWRRWLJKWÀDUHQXWPDHYHQWXDOOEUHDNDQGFDXVHUHIULJHUDQWOHDNDJH Indoor unit connection Connect both liquid and gas pipings to indoor unit.
5-3. PUMPING DOWN When relocating or disposing of the air conditioner , pump down the system following the procedure below so that refrigerant is not released into the atmosphere. 1) Connect the gauge manifold valve to the service port of the stop valve on the gas pipe side of the outdoor unit.
デバイスMitsubishi Electronics MSZ-FD09/12NAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Mitsubishi Electronics MSZ-FD09/12NAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMitsubishi Electronics MSZ-FD09/12NAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Mitsubishi Electronics MSZ-FD09/12NAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Mitsubishi Electronics MSZ-FD09/12NAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Mitsubishi Electronics MSZ-FD09/12NAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMitsubishi Electronics MSZ-FD09/12NAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Mitsubishi Electronics MSZ-FD09/12NAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMitsubishi Electronics MSZ-FD09/12NAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。