MotionメーカーActuatorの使用説明書/サービス説明書
ページ先へ移動 of 32
ServoTube 38 INSTALLATION GUIDE Publication Ref: UM03013/A Copley Motion Systems LLC Luckyn Lane, Pipps Hill, Basildon, Essex SS14 3BW England Tel: +44 (0)1268 287070 Fax +44 ( 0)1268 293344 Copley Controls Corp.
WARRANTY Copley Motion Systems guarantees it s equipment against faulty component s for a period of twelve months from delivery . Replacement components will be free of charge. Copley M otion Systems shall not in any event be li able for consequential damage or loss.
ServoTube 38 INSTALLATIO N GUIDE Contents Preliminary p ages T itle page ............................................. (i) Copyright notice / disclaimer .................................. (ii) Contents list (this p age) ...............................
WARNINGS W arning symbols and meanings In this User Manual warning symbols are used. These are intended to alert you to the potent ial hazards to personnel which are associated with the equipment described, in all aspects of use, including handling, installation, operation and maintenance.
READER’S NOTE S GENERAL This manual describes the Installation, Maintenance and S p ares of the ServoT ube 38 linear motor . ASSOCIATED PUBLICATIONS The following publications are associated with the ServoT ube 38 User Manual.
Page ( vi) Prelims ServoTube 38 Installation Guide.
SERVOTUBE 38 ACTUATOR The ServoT ube 38 Actuator is an optimal solution for industrial position control. Faster than a ballscrew with the clean reliability of a linear motor , the ServoT ube 38 is a cost-effective alternative to air cylinders in applications requiring greater flexibility and control.
The tubular motor has superior thermal ef ficiency , radiating heat uniformly . High duty cycles are possible without the need for forced-air or water cooling. Amplifiers ServoT ube 38 is complemented by a range of matched, self-tuning servo-amplifiers and indexers complete with plug-and-play cabling.
Chapter 2 Installation UNPACKING • Check packaging for signs of damage. • Metal surfaces may be hot or below 0 o C following prolonged storage. • Remove packaging. Do not discard. In the event of items requiring return, it is recommended that the original packaging be used.
Mechanical - XT A The outline drawing of the XT A is shown in Figure 2.1. It comprises the forcer with an integrated plastic sleeve bearing and the thrust rod. The integrated bearing act s as a guide for the moving thrust rod. It is not intended to wit hstand side loading.
Page 5 ServoTube 38 Installation Guide ` Chapter 2 Installation XT A3804 XT A3806 XT A3808 XT A3810 ALL DIMENSIONS IN MM THRUST ROD Note: 1. Actuator is double acting T olerance +/- 2mm 33.0 70.0 42.0 40.3 38.2 84.0 38.0 43.0 43.0 4 MTG HOLES M6 X 10 DEEP 141 12.
Mechanical - XTB The XTB is shown in Figure 2.2. It comprises the forcer and the thrust rod. Wit h the addition of thrust rod supports and a linear bearing a moving forcer solution can be implemented.
Page 7 ServoTube 38 Installation Guide ` Chapter 2 Installation THRUST ROD XTB3804 XTB3806 XTB3808 XTB3810 ALL DIMENSIONS IN MM 40.0 33.0 70.0 42.0 40.3 38.0 84.0 218.0 12.0 70.0 174.0 29.0 PITCH TYP 60.0 8 MTG HOLES M4 X 8 DEEP 5.5 59.0 = 58.0 = = 37.
Electrical All electrical connections to the XT A and XTB are made via two cables, see Figure 2.3. One carries power to the forcer and the other carries signals from the position sensor . These cables are supplied either pre-terminated for a specific drive or with flying leads.
Chapter 3 Maintenance XT A The XT A is low maintenance and as such requires only minimal periodic inspection. The integral bearing is dry running, requiring no lubrication. Periodically: • Check that the thrust rod can move freely over the entire stroke.
• Loosen the two fixings on the cable clamp. • Pull the cable out through the cable gland. Replacement Re-fitting is the reverse of the removal procedure. • Feed the new cable(s) through the cable gland. • Connect the cable(s) including the earth lead.
Chapter 4 Service SERVICE Should you need to return any items to Copley Mot ion Systems, before doing so, please call our Sales co-ordinator on +44 (0)1268 287070 or send a fax to +44 (0)1268 293344 in order to obtain an RMA (Returned Materials Authorisation) number .
Page 12 Chapter 4 ServoTube 38 Installation GuideService.
Appendices CONTENTS APPENDIX A - GLOSSARY OF TERMS & ABBREVIATIONS APPENDIX B - TROUBLE SHOOTING APPENDIX C - TECHNICAL SPECIFICATION Page 13 ServoTube 38 Installation Guide Appendices.
Page 14 Appendices ServoTube 38 Installation Guide.
Appendix A Glossary of Terms & Abbreviations GLOSSARY OF TERMS TERM DESCRIPTION O F TERM Peak force Peak force is the force produc ed when the peak current is applied to the motor. It is the product of Force constant (N/A pk ) and Peak current (A pk ).
TERM DESCRIPTION O F TERM Electrical time constant Electrical time constant is the time taken f or a step current input to t he motor to reach 63.2% of its value. Continuous working voltage Continuous working voltage is the maximum allowable continuous voltage between any two motor phases or between any motor phase and the motor safety earth.
Appendix B Troubleshooting TROUBLESHOOTING CHART Check to see if the problem you are experiencing is listed in the chart below . If the problem cannot be solved with reference to this chart, contact the customer services dep artment. Fault Possible cause A ction Forcer/thrust rod f ails to move and produces no force.
Page 18 Appendices ServoTube 38 Installation Guide.
Appendix C Technical Datasheet ELECTRICAL SPECIFICATIONS MOTOR TYPE 3804 3806 3808 3810 units S (1) P (1) S (1) P (1) S (1) P (1) S (1) P (1) Peak force @ 25 o C ambient for 1 sec 744 372 1116 558 1488 744 1860 930 N Peak current @ 25 o C ambient for 1 sec 20 20 20 20 20 20 20 20 A pk With 25 x 25 x 2.
THERMAL SPECIFICATIONS MOTOR TYPE 3804 3806 3808 3810 units Maximum phase temperature 100 100 100 100 o C Thermal resistance R thphase-housing 0.23 0.16 0.13 0.11 o C/W With 25 x 25 x 2.5 cm heatsink plate Power dissipation @ 25 o C ambient 89.3 110.3 127.
POSITION SENSOR The position sensor outputs analogue, dif ferential sine and cosine signals for providing position feedback. Figure C. 1 shows the relationships between motor phase back EMF and position sensor output s for one direction of motion (as shown by arrows in Figures C.
MOTOR OVER TEMPERATURE SENSOR It is strongly recommended that the motor over-temperat ure sensor is connected to the drive amplifier or servo controller at all times in order to reduce the risk of damage to the motor due to ex cessive temperatures.
CONNECTIONS Connections within the forcer termination box are as follows: TB1 FUNCTION CONDUCTOR DESIGNATION 1 Motor phase U Black 1 2 Motor phase V Black 2 3 Motor phase W Black 3 Chassis Protective .
XTA FORCE / VELOCITY PROFILES (WITH AN OPERATING VOLTAGE OF 325 VD.C.) S=series motor phases P=parallel motor phases Page 24 Appendices ServoTube 38 Installation Guide XT A3804S force/velocity PEAK CO.
XTB FORCE / VELOCITY PROFILES (WITH AN OPERATING VOLTAGE OF 325 VD. C.) S=series motor phases P=parallel motor phases Page 25 ServoTube 38 Installation Guide Appendices XTB3804S force/velocity PEAK CO.
Ref: UM03013/A Luckyn Lane, Pipps Hill, Basildon, Essex SS14 3BW England Tel: +44 (0)1268 287070 Fax +44 ( 0)1268 293344 Copley Controls Corp. Copley Motion Systems LLC.
デバイスMotion Actuatorの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Motion Actuatorをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMotion Actuatorの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Motion Actuatorの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Motion Actuatorで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Motion Actuatorを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMotion Actuatorの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Motion Actuatorに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMotion Actuatorデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。