1 NPort 6110 Modbus/TCP to Serial Communication Gateway User ’ s Manual Second Edition, November 2004 Moxa Technolog ies Co., Ltd. Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 Web: www.moxa.com MOXA Technical Support Worldwide: support@moxa.com.tw The Americas: support@moxa.
.
2 NPort 6110 Modbus/TCP to Serial Communication Gateway The software described in this manual is furnished under a licen se agreement and may be used only in acco rdance with the terms of that agreement. Copyright Notice Copyright 2004 Moxa T echnologies Co.
.
MOXA Internet Services Customer satisfaction is our number on e concern. T o ensure that customers receive the full benefit of our products, Moxa Internet Services has been set up to provide technical support, dri ver updates, product information, and user’ s ma nual updates.
.
Table of Contents 1. Introduc tion....................................................................................... 1-1 Overview ....................................................................................... 1-1 Features ...............
1-2 Unlock ................................................................................. 4-15 Upgrade Firm ware .............................................................. 4-15 Remote Monitoring and Managem ent................................. 4-17 5.
1-1 1 1 1. Introduction Welcome to M oxa NPort 6110 Modbus/TCP to Serial Commun ication Gateway , an easy-to-use Ethernet to RS-232/42 2/485 Modbus Gateway.
1-2 port that can c o nnect to m any types of Mod bus device. By t r anslating Modbus/TCP (Et h ernet) and Modb us/ASCII/RT U (Serial) protoc ols, a PLC with Ethernet can use the RS-232/485 inte rface to seam lessly c ommunicate with instruments.
1-3 Product Specifications LAN Ethernet 10/10 0 Mbps, R J45 Protection Built-in 1.5 KV magnetic isolation Serial Interface RJ-232/422/485 x 1, DB9 (M), so ftware selectable RS-232 Signals TxD, RxD, RT.
1-4 Environmental Operating Tem perature 0 to 55°C (32 t o 131°F), 5 to 95% RH Storage Temperat ure -20 to 85°C (-4 to 185° F), 95% RH Regulatory Approv als EMC FCC Class B, CE Class B Safety CUL,.
1-5 Front/Top/Rear/Bottom Panel Views 21.3 42.3 67 (2.64") unit = mm (inch) (0.8") 100.4 (3.95") (1.67") 22.0 (0.87") 4 90.2 (3.
.
2-1 2 2 2. Getting Started This chapter includes: ❑ Power Connect ion ❑ Serial Installation ❑ Ethernet Installation ❑ Software Installation ❑ Housing " DIN-Rail " Wall Mount Power Connection Take the following step s to connect NPort 6110’s pow er adapter.
2-2 Ethernet Installation There a re two ways to u se the 10/10 0Bas eT Ethernet jack located on NPort 6110’s front pane l: 1. For most applications using NPort 6110, you will simply plu g one end of an Ethernet cable in to NPort 6110’s 100BaseT jack, and p lug the other en d into an Ethernet hub/switch connected to your network.
2-3 2. You will be greeted by the Welcome window. Click on Next to continu e. 3. Enter your Name and Co mpany name in the spaces provided, a nd then click on Next to continue. 4. When the Choose Destination Locati on window appea rs, click on Next to continue.
2-4 5. If desire d, modify the highlig hted name i n the Program Folders text box (thi s is the name that will appear under Start # Program s ) and then click on Next to conti nue.
2-5 6. Click on Next to start copying the software files. 7. Wait patiently while the files are bein g copied. The pro cedure should on ly take a few seconds. 8. The NPort Modbus Gateway Utility folder will open showing the Modbus Gateway Configurator icon.
2-6 9. You m ay also view t his program short cut by cli cking on Start # Progra ms # NPort Modbus Gateway Utility # Modbus Gateway Configurator , as shown below.
2-7 Housing DIN-Rail For many industrial applications, you w ill find it convenient to use the DIN-Rail attachments, as shown below. STEP 1: Use 2 screws per ear to att ach DIN-Rail mounts to each of NPort 6110’s two ears. ⇒ STEP 2: Insert the top o f the DIN-Rail into the top slot of the DIN-Rail mount.
2-8 Wall Mount For many industrial applications, you will find it convenient to mount NPo rt 6110 on the wall, using t wo screws, as indicated bel o w. STEP 1: Scre w two screws , separated by 7.8 cm, into the wall. The heads of the screws should be no greater than 6.
3-1 3 3 3. Typical Modbus Applications In this chapter, we introduce three typical Mo dbus applications. Serial master device talks to serial slave devices over the Internet Let traditional Modbu s se.
3-2 Ethernet master devices talk to multiple serial slave devices Connect all Modbus d evices over the Ethernet network… Most host computers and newly develope d PLCs support the Ethernet interface and run Modbus/TCP. NPort 6110 Modbu s Gateway is needed to link discr ete Serial Modbus Devices for data collect ion and c ontrol.
3-3 Serial master devices talk to multiple Ethernet slave devices Link the Serial Master device with Ethernet Slave devices… Many HMI (Human Machine Interface) sy stems use a seria l interface and are required to access a discrete DCS (Dat a Control System).
.
4-1 4 4 4. Configuring Modbus Gateway We discuss the following topics in this chapter: ❑ Starting Modbus Gateway Conf igurator ❑ Searching fo r NPort 6110 " Broadcast Search " Specify by.
4-2 Starting Modbus Gateway Configurator To start Modb us Gateway Configurato r, click on Start # Programs # NPort Modbus Gateway Utility # Modbus Gateway C onfigurator .
4-3 Searching for NPort 6110 There are two methods available to searc h the network for NPort 6110s. Broadcast Search is u sed to locate all NPort 61 10s connected to the same LAN as the host, and Se .
4-4 When the Sear ch by IP Address wi ndow opens, input the I P address of th e NPort 611 0 you want t o search for, and t hen click OK . If the search is successful, informati on related to the NPort 6110 will be displayed in the Modbus Gatew ay Configurator window.
4-5 The Configurati o n window ope ns to the Network Settings pa ge. Refer to the following subsection s to learn more about how to configur e NPort 6110’s various settings. Network Settings The Network Settings page is use d to configu re Modbus Gateway Name , IP Address , Net mask , Default Gat eway , and IP Configuration .
4-6 Network Setti ngs Setting V alue Notes Modbus Gateway N ame Alp hanumeric Choose a name that easily identifies the Gateway’ s location, function, etc. IP Address 32-bit number , default = 192.168.127.25 4 The IP (Internet Pr otocol) address identifies the serv er on the TCP/IP network.
4-7.
4-8 Modbus Settings Setting V alue No tes Modbus R TU Slave 1 Modbus ASCII Slav e 2 Modbus R TU Master 3 Attached Serial Device type Modbus ASCII Master 4 Set the Modbus type of the serial device attached to NPort 61 10’ s serial port.
4-9 4. Modbus ASCII Master mode works th e same as Modbus/RTU Master mode, except that the data fo rmat is Modb us/ASCII. 5. When the NPort Modbus Gat eway recei ves a command from the serial port, the ID No. range table is used identify wh ich IP address to connect to (e.
4-10 Advanced Mo dbus Settings Setting V alue No tes Enable (Defau lt) Auto Slave Unit ID Disable Select En able wh en multiple Modbus devices are accessible at the sam e IP address. 1 Character T imeout 10 to 3000 ms (default = 100 ms) This parameter is active when the attached serial device is set to Modbus/R TU.
4-11 when Auto Slave Unit ID is “Disabled.” 2. When the Modbus serial prot ocol is set to Modbus/RTU, each message packet is determined by a character tim eout.
4-12 Modbus Serial Settings The Modbus Serial Settings page is used to configure NPor t 6110’s DB9 Male port. You can configure Interface Mode , Baud Rate , Parit y , Data Bits , Stop Bit , Flow Control , and UART FIFO .
4-13 Modbus Serial Settings Setting V alue No tes RS-232 RS-422 Interface Mode RS-485 NPort 6110 supports 2-wire RS- 485 mode. Baud Rate 1200 bps to 230400 bps Parity None, Odd, Even, Space, Mark Data.
4-14 Password Use the Password page to set a passwo rd, change the password, or erase the password. NOTE To modify the settings on this page, you must first checkmark the Change Passw ord box at the top of the Password page.
4-15 Other Functions The Unlock , Start L og Monitor , and Upgrade Firmw are functions a r e described in th is section. Unlock The Unlock fu nction is used f or NPort 6110 units that are password protected.
4-16 When the Open window a ppears, navigate to the fol der that cont ains the NPort 6110 firmware file, a nd then click on the file name. M ake sure the co rrect filename appea rs in the File name box, a nd then click on the Open bu tton to start downloading t he firmware.
4-17 Remote Monitoring and Management To troublesh oot and manage Modbus-based device connect ivity, information such as TCP/IP , Modbus pro tocol type, and Master/Sla ve type are im portant. NPort Modbus Gateway provides a powerful function that allows you to monitor the operation of each Modbus Gateway on the In ternet.
4-18 To start capturing the operation log, press the Start Log Moni tor button . The operation log appears with time stamp stating conn ection status for connected Modbus devices. To keep a reco rd of this monitor session, save the log to a text file.
5-1 5 5 5. Troubleshooting In this chapter, we give answers to some comm on troubleshooting q uestions related to Modbus Gateway applications. 1. ID No.
.
6-1 6 6 6. Pin Assignments NPort 6110 supports three serial interfaces: RS-232, RS -422, and 2-wire RS-485. In this chapter, we give the DB9 Male pinouts for each of these three interfaces.
.
A-1 A A A. Declaration of Conformity Manufacturer’ s Name: Moxa Technologies Co., Ltd. Manufacturer’ s Address: Fl.4, No.135, Lane 235, Pao-C hiao Rd.
.
B-1 B B B. Problem Report Form NPort 6110 Modbus Gateway Customer name: Company: Te l : F a x : Email: Date: 1. Moxa Pr oduct: $ NPort 61 10 (1 RS-232/422/485 port) 2. Interface: $ RS-232 $ RS-422 $ RS-485 (2-w ire) 3. Attached serial device type: $ Modbus/ASCII ○ Master ○ Slave $ Modbus/R TU ○ Master ○ Slave 4.
B-2 RETURN PROCEDURE For product repair , exchange, or refund, t h e customer m ust: ♦ Provide e vidence of origi nal purchase. ♦ Obtain a Product Return Agreement (PRA) from the sales representative or dealer . ♦ Fill out the Problem Report Form (PRF).
デバイスMoxa Technologies 6110の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Moxa Technologies 6110をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMoxa Technologies 6110の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Moxa Technologies 6110の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Moxa Technologies 6110で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Moxa Technologies 6110を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMoxa Technologies 6110の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Moxa Technologies 6110に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMoxa Technologies 6110デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。